中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
Characterization of local regional atmospheric turbulence by parallel laser beams 会议论文  OAI收割
Kunming, China, 2021-12-07
作者:  
Deng J(邓鉴);  Song TF(宋腾飞);  Liu Y(刘煜)
  |  收藏  |  浏览/下载:7/0  |  提交时间:2024/05/13
An Effective Emission Depth Model for Passive Microwave Remote Sensing SCI/SSCI论文  OAI收割
2016
作者:  
Zhou F. C.;  Song, X. N.;  Leng, P.;  Li, Z. L.
  |  收藏  |  浏览/下载:39/0  |  提交时间:2017/11/09
An Effective Emission Depth Model for Passive Microwave Remote Sensing SCI/SSCI论文  OAI收割
2016
作者:  
Zhou F. C.;  Song, X. N.;  Leng, P.;  Li, Z. L.
收藏  |  浏览/下载:47/0  |  提交时间:2016/12/16
Advanced astigmatism-corrected tandem Wadsworth mounting for small-scale spectral broadband imaging spectrometer (EI CONFERENCE) 会议论文  OAI收割
作者:  
Lin G.-Y.
收藏  |  浏览/下载:40/0  |  提交时间:2013/03/25
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution  high spectral resolution  and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror  it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating  which make the anterior Wadsworth condition fulfilling each wavelength  is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband. 2012 Optical Society of America.  
Space camera dynamic image quality measurement and evaluation (EI CONFERENCE) 会议论文  OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
The compression and storage method of the same kind of medical images-DPCM (EI CONFERENCE) 会议论文  OAI收割
4th International Conference on Photonics and Imaging in Biology and Medicine, September 3, 2005 - September 6, 2005, Tianjin, China
作者:  
Liu H.;  Liu H.;  Liu H.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
Medical imaging has started to take advantage of digital technology  opening the way for advanced medical imaging and teleradiology. Medical images  however  require large amounts of memory. At over 1 million bytes per image  a typical hospital needs a staggering amount of memory storage (over one trillion bytes per year)  and transmitting an image over a network (even the promised superhighway) could take minutes - too slow for interactive teleradiology. This calls for image compression to reduce significantly the amount of data needed to represent an image. Several compression techniques with different compression ratio have been developed. However  the lossless techniques  which allow for perfect reconstruction of the original images  yield modest compression ratio  while the techniques that yield higher compression ratio are lossy  that is  the original image is reconstructed only approximately Medical imaging poses the great challenge of having compression algorithms that are lossless (for diagnostic and legal reasons) and yet have high compression ratio for reduced storage and transmission time. To meet this challenge  we are developing and studying some compression schemes  which are either strictly lossless or diagnostically lossless  taking advantage of the peculiarities of medical images and of the medical practice. In order to increase the Signal to-Noise Ratio (SNR) by exploitation of correlations within the source signal  a method of combining differential pulse code modulation (DPCM) is presented.