中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
数学与系统科学研究院 [1]
寒区旱区环境与工程研... [1]
采集方式
OAI收割 [3]
iSwitch采集 [1]
内容类型
会议论文 [2]
期刊论文 [2]
发表日期
2012 [1]
2010 [1]
2009 [1]
2008 [1]
学科主题
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Research of ballistic missile early warning system (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Advanced Engineering Materials and Technology, AEMT 2012, July 6, 2012 - July 8, 2012, Zhuhai, China
Zhang M.-H.
;
Zhang Y.-Y.
收藏
  |  
浏览/下载:48/0
  |  
提交时间:2013/03/25
To develop a lift early warning infrared device
as a part of land or boat (ship) early warning system
the system has the ability to target pre-discovery and instructions invasion. Methods: In support of distant air situation
alerts the enemy aircraft
missiles and other long-range goals
obtain the target type and preliminary judgment of grade
deliver the alarm information to the command system. The infrared alarm device detects the target's own infrared radiation passively
alarms the incoming targets at low altitude and low altitude remote
when radar and other equipment is out of work. Results: The accuracy of entire system reached 20 according the analysis. Conclusions: The device has a full range of complex background
with high sensitivity
high resolution
anti-jamming
fast response time and other characteristics. (2012) Trans Tech Publications
Switzerland.
Measuring instrument for radial composite deviations of high-precision master gear (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
作者:
Zhang Y.
;
Wang L.
;
Wang L.
;
Wang L.
收藏
  |  
浏览/下载:69/0
  |  
提交时间:2013/03/25
During double flank rolling composite detection
the radial composite deviations of master gears has been existed and transferred to the measured gear by the primary harmonic curve. In order to improve measurement accuracy
a measuring instrument is developed for radial composite deviations of high-precision master gear in the paper. This instrument uses the structure of spring-suspend swing span to overcome the shortcomings of large rotation errors
low sensitivity
low resolution and large measuring force appearing in the traditional combination-type gear inspection instrument. Artificial intelligence technology is used to improve the efficiency and accuracy of this instrument. The result is that the measuring apparatus is able to meet the requirement and improve efficiency through the measuring experiments on master gears of precision grade 2 with modulus 2 mm and 3 mm
respectively. 2010 SPIE.
Checking the adequacy of a general linear model with responses missing at random
期刊论文
OAI收割
JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2009, 卷号: 139, 期号: 10, 页码: 3588-3604
作者:
Sun, Zhihua
;
Wang, Qihua
  |  
收藏
  |  
浏览/下载:46/0
  |  
提交时间:2018/07/30
General linear model
Lack-of-fit test
Missing at random
Score-type test
Empirical process
Sensitivity analysis
Sensitivity analysis of glacier systems to climate warming in China
期刊论文
iSwitch采集
JOURNAL OF GEOGRAPHICAL SCIENCES, 2008, 卷号: 18, 期号: 2, 页码: 190-200
作者:
Wang Xin
;
Xie Zichu
;
Li Qiaoyuan
;
Wang Shuhong
;
Cheng Lei
收藏
  |  
浏览/下载:50/0
  |  
提交时间:2019/10/08
glacier system
functional model
response to climate warming
type of sensitivity