Electronic system design of ultraviolet ozone vertical profile probe for aerography satellite (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Song K.
;
Wang S.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
The design of ultraviolet ozone vertical profile probe is illustrated and the electronic system is introduced in detail. The device is a compact
high precision
ultraviolet-vacuum
ultraviolet spectral radiometer
and is used to measure atmospheric solar backscattering spectral radiance and solar spectral irradiance. Noise of the system is analyzed and Numeric accumulation and synchronous demodulation was used to decrease the noise and the zero-drift of the instrument. The solar irradiance at altitude 830 km in 160-400 nm and the backscattering solar spectral radiance in the ultraviolet ozone absorption band at 12 wavelengths from 250 nm to 340 nm are obtained. Test results on orbit show that all the requested function is met successfully and the performance is stable. 2011 IEEE.
UV-VUV spectral irradiance responsivity calibration for space remote sensing spectroradiometer (EI CONFERENCE)
会议论文
OAI收割
Advanced Materials and Devices for Sensing and Imaging III, November 12, 2007 - November 14, 2007, Beijing, China
作者:
Yu H.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
In order to overcome the irradiance responsivity calibration troubles caused by the weak response of most spectral radiometers in ultraviolet band and poor ratio of signal to noise
and to meet special calibration condition for some remote sensing spectroradiometers in space
a spectral irradiance responsivity calibration unit based on parallel light illumination mode is established
it is composed of a 150W deuterium lamp and a spherical mirror. The calibration unit gets the output standard value of spectral irradiance by irradiance transfer
this way avoids the spectral reflectance measurement difficulty of the spherical mirror. A flight spectral radiometer model used for space remote sense was calibrated in range from 160nm to 300nm
the calibration error of spectral irradiance responsivity is 4.7%. Some factors which contribute to calibration uncertainties are discussed.