A wide-band interference spectrometer based on bandpass sampling technology
会议论文
OAI收割
Hefei, China, 2020-09-25
作者:
Tian, Feifei
;
Li, Siyuan
  |  
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2021/01/20
band-pass sampling
interference spectrometer
wide-band spectrum
resolution
signal-to-noise ratio
Athermal design of hybrid refractive/harmonic diffractive optical system for far-infrared multi-band (EI CONFERENCE)
会议论文
OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Advanced Optical Manufacturing Technologies, November 19, 2008 - November 21, 2008, Chengdu, China
作者:
Liu Y.
;
Liu Y.
;
Zhang H.
;
Zhang H.
;
Sun Q.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
In order to get enough information about the target
avoid big chromatic aberration as a result of wide spectrum and the complexity of optical system and adapt different special environment temperature
a hybrid refractive/harmonic diffractive optical system in far-infrared multi-band is described in the paper. This diffractive optical system has been designed an athermalized multi-band imaging system with harmonic diffractive element in 15-50m spectrum
based on larger 1dispersion capability and particular thermal dispersive power of harmonic diffractive element. Then
at the temperature range from 0C to 40C
this design can simultaneously meet with all requirements of the imaging system in five harmonic wave bands
including15.8-16.2m
18.5-20m
23-25m
30.5-33.5m and 46-50m. In each harmonic wave band
the magnification changes as a function of wavelength
which creates image registration error. To compensate this shortcoming
a zoom optical system is designed with three lenses by means of optical two- component method. The design results show that the hybrid refractive/harmonic diffractive optical system can realize athermalized and achromatic design
and the zoom optical system makes half image height at 3.53mm in every harmonic wave band and still realizes aberration compensation action. In the five harmonic wave bands
each optical transfer function approaches the diffraction limit at ambient temperature range of 0C to 40C. Finally
the system realizes the requirements of portability
mini-type and ease for fabrication. 2009 SPIE.
Design of a scene simulator in land-based aerospace lab with the man-made light source system based on quantum theory (EI CONFERENCE)
会议论文
OAI收割
Optoelectronic Devices and Integration II, November 12, 2007 - November 15, 2007, Beijing, China
作者:
Fang W.
;
Yi W.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
The paper presents a method with the technique of combination filtering of spectrum and the technique of DSP control for the simulation and recognition of the spontaneously lightening object and stellar map in the universe. The magnitude and the spectrum of a star can be simulated in a wide dynamic range. We established the mathematical models of the Vega's visible light spectrum and luminous flux density. Tungsten-halogen lamp as a light source is used to fit the linear light of the spontaneously lightening object in the universe. Through the experiment
it shows that the more sub-channels there are while filtering spectrum in the visible spectrum
and the more degrees the variable neutral density filters and the narrow-band attenuators have
more close to the actual spectrum the simulated spectrum is. It is proved that using the PID technique is beneficial to the output of the accurate and steady radiation from the light sources. The experiment shows that the using of this method can get perfect result in fitting and simulating the spectrum
magnitude and the stellar map of the spontaneously lightening object . The analysis of the consistent result and the experimental error is also discussed in detail in this paper.