Space optical remote sensor of the CAE thermal control index calculation method (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Advanced Design and Manufacturing Engineering, ADME 2011, September 16, 2011 - September 18, 2011, Guangzhou, China
作者:  
Li L.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
The thermal control indicators CAE methods of Space optical remote sensor are analyzed in the presented work. We sat up a thermal optical analysis model for space optical remote sensor. By assuming fully covered by in-orbit temperature load  and using the finite element method for thermal deformation analysis  we obtained the optical remote sensor surface deformation and displacement under various thermal loading. Using ZERNIKE polynomial  wave was fitted to obtain ZERNIKE polynomial coefficients which were incorporated into the optical system design. Using CODE V optical calculation software  heat-ray machines under elastic deformation of the system point spread function  transfer function (MTF)  wave front differential (WFE) etc. were calculated. Image quality changes of remote sensors are discussed in variety assumed cases such as temperature loads of quality change. By repeated iteration  critical value of temperature fields meeting the design requirements are obtained for the optical system. Optical indicators were converged to the temperature field indicator  then reasonable indicators of thermal control for remote sensors were obtained. For the thermal control design  this method provided a reliable basis for design. (2011) Trans Tech Publications  Switzerland.  
Pre-process technique study of a high performance remote image sensor structural Finite Element Analysis (EI CONFERENCE) 会议论文  OAI收割
2010 2nd International Conference on Computer Engineering and Technology, ICCET 2010, April 16, 2010 - April 18, 2010, Chengdu, China
作者:  
Zhang L.;  Xu Y.-S.;  Zhang L.
收藏  |  浏览/下载:15/0  |  提交时间:2013/03/25
High precision structural Finite Element Analysis (FEA) results are required in the development of a remote image sensor. HperMesh and MSC. Nastran are employed in the image sensor structural FEA. This paper discusses some technical issues about the Finite Element (FE) modeling of the image sensor. In order to obtain authentic analysis results  the part-to-whole handling schema  i.e. handling method and research work is implemented in a small part of the model firstly and a revised method is used in the whole structural in succession  has been proposed. Some emphasis is mainly put on the FE handling of bolted joint  bearing and inter-element connection. The interface handling methods  such as CBEAM plus partial MPC bolted joint model  hybrid element bearing model and RBE3 beam-to-solid connection  have been produced and successfully implemented in the image sensor structural FEA. 2010 IEEE.  
Design of high-resolution fourier transform lens (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Zhang L.;  Zhang L.
收藏  |  浏览/下载:14/0  |  提交时间:2013/03/25
With the development of optical information processing  high-resolution Fourier transform lens has often been used in holographic data storage system  spatial filtering and observation of particles. This paper studies the optical design method of high-resolution Fourier transform optical lenses system  which could be used in particles observation and holographic data storage system. According to Fourier transform relation between object and its frequency plane and the theory of geometrical optics  the system with working wavelength 532nm and resolution 3 m was designed based on ZEMAX. A multi-configuration method was adopted to optimize the system's lenses. In the optical system  a diaphragm was placed at the system's spectrum plane and the system demanded a low vacuum to cut down the influences of atmosphere and other particles. The result of finite element analysis indicated that the influences of vacuum pumping to optics spacing and mirror surface shape very minor  and the imaging quality not being affected. This system has many advantages  such as simple structure  good image quality and a high resolution of 3 m. So it has a wide application prospect and can be used both in holographic data storage system and particles observation.  
Design and analysis of large spaceborne light-weighted primary mirror and its support system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Large Mirrors and Telescopes, July 8, 2007 - July 12, 2007, Chengdu, China
Yan Y.; Jin G.; Yang H.-B.
收藏  |  浏览/下载:14/0  |  提交时间:2013/03/25
With the development of the resolution of spaceborne remote sensor  the diameter of the primary mirror of spaceborne telescope becomes larger and larger. The distortion of primary mirror which is influenced by the mirror material  structure  self-weight  support system and temperature environment affects optical image quality finally. In this paper  an on-axis TMA high-resolution Cassegrain optical payload with a primary mirror whose diameter is 650mm was designed and the effects of the influence factors of the distortion acts on the on-axis TMA optical system primary mirror had been analyzed by means of Finite Element Analysis. During work  the technology of the primary mirror design had been summarized and general consideration of the primary mirror design technology also had been described at the same time. Considering the telescope manufacture and work station  a reasonable and optimal structure of the primary mirror sub-assembly is taken finally. In the end  the distortion of the primary mirror during its fabrication station and work station had been analyzed by integrated Finite Element Analysis Method. The results implicated the synthesis profile error (P-V value) for the primary mirror is less than /10 and all the indexes of the primary mirror satisfy the requirements of the optical system.