基于一种远程双脉冲激光诱导击穿光谱系统原位分析钢样成分

文献类型:期刊论文

作者辛勇; 孙兰香; 杨志家; 李洋; 丛智博; 齐立峰; 张鹏; 曾鹏
刊名光谱学与光谱分析
出版日期2016
卷号36期号:7页码:2255-2259
关键词激光诱导击穿光谱 远程 双脉冲 在线
ISSN号1000-0593
其他题名In-situ analysis of solid steel samples with remote double-pulse laser-induced breakdown spectroscopy system
产权排序1
通讯作者孙兰香
中文摘要为了实现钢铁等金属熔炼过程中实时、在线监测元素组分含量,设计了一种远程双脉冲激光诱导击穿光谱(LIBS)分析系统,对远距离的样品进行非接触式远程测量、成分分析。首先利用固体标准钢样对系统进行了测试以及标定,为下一步利用此系统在线监测熔融钢液组分含量提供了基础。实验结果表明:激光远距离聚焦光斑在1 mm左右;双脉冲烧蚀比单脉冲烧蚀深度深很多;双脉冲最佳延时在不同距离下不一致;3.1 m处双脉冲增强效果比2.1 m处更好,其中Ti(Ⅰ)319.99 nrn增强最显著为5.19倍;各种元素的标定曲线相关系数r都在0.99左右,重复精度(RSD)基本都小于5%,测量偏差(RMSE)都小于0.021%,2.1m处的检出限相比3.1 m处更低,2.1 m处多数元素检出限小于500 ppm。
英文摘要In order to realize real-time, online monitoring of the component of steel and other metal smelting process, we designed a remote double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system which can realize non-contact remote measurement and component analysis for long distance sample. The paper first tests the system on solid standard steel samples, which provides basis for online monitoring the component of molten steel. The experimental results show:laser focal spot is about 1mm in long distance; double-pulse ablation depth is deeper than single pulse's; the optimum delay of double-pulse is non-consistent in different distances; the enhancement effect of double- pulse in 3.1 m is better than that in 2.1 m, and the maximum enhancement is 5.19 of Ti(I) 319.99 nm; the calibration curve of R2is about 0.99, RSD being less than 5%, RMSE being less than 0.021%, LOD being less than 500 ppm for most elements in 2.1 m, which is better than that in 3.1 m.
WOS标题词Science & Technology ; Technology
类目[WOS]Spectroscopy
研究领域[WOS]Spectroscopy
关键词[WOS]OPTICAL-EMISSION ; LIQUID STEEL ; METALS ; ENHANCEMENT ; ABLATION ; PLASMAS ; LIBS
收录类别SCI ; EI ; CSCD
语种中文
CSCD记录号CSCD:5752632
WOS记录号WOS:000379990300047
源URL[http://ir.sia.cn/handle/173321/18817]  
专题沈阳自动化研究所_工业控制网络与系统研究室
推荐引用方式
GB/T 7714
辛勇,孙兰香,杨志家,等. 基于一种远程双脉冲激光诱导击穿光谱系统原位分析钢样成分[J]. 光谱学与光谱分析,2016,36(7):2255-2259.
APA 辛勇.,孙兰香.,杨志家.,李洋.,丛智博.,...&曾鹏.(2016).基于一种远程双脉冲激光诱导击穿光谱系统原位分析钢样成分.光谱学与光谱分析,36(7),2255-2259.
MLA 辛勇,et al."基于一种远程双脉冲激光诱导击穿光谱系统原位分析钢样成分".光谱学与光谱分析 36.7(2016):2255-2259.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。