Challenges on field monitoring of indoor air quality in china

文献类型:期刊论文

作者Huang, Yu1,3; Cao, Junji1,3; Lee, Shun-Cheng2; Ho, Steven Sai Hang1,4
刊名INDOOR AND BUILT ENVIRONMENT
出版日期2017-04-01
卷号26期号:4页码:576-584
关键词Indoor Air Quality Field Monitoring China Measurement Protocols Exposure
DOI10.1177/1420326X15626991
文献子类Article
英文摘要Field monitoring is critical in the examination of indoor air quality (IAQ) which offers an integrated assessment of human exposure. A good measurement protocol includes appropriate methodologies and compliance of quality control and quality assurance procedures. In China, there has been a huge economic growth in the past 20 years and living standard for Chinese citizens has been improving with a rapid development in urban cities and infrastructures. With these developments, there have been a growth of increasing pollution sources, and IAQ has been a major concern to the government and many Chinese citizens with widespread reports of the coherent health impacts. However, the indoor monitoring in China is full of technical challenges. In this paper, we review the difficulties in conducting IAQ assessment in China. Techniques and practical consideration have been proposed accordingly.
WOS关键词SOLID-PHASE MICROEXTRACTION ; LARGE ENVIRONMENTAL CHAMBER ; VOLATILE ORGANIC-COMPOUNDS ; PARTICLE CONCENTRATIONS ; BUILDING PATHOLOGY ; PASSIVE SAMPLER ; SICK BUILDINGS ; VOC EMISSIONS ; FORMALDEHYDE ; OUTDOOR
WOS研究方向Construction & Building Technology ; Engineering ; Public, Environmental & Occupational Health
语种英语
WOS记录号WOS:000400158700012
源URL[http://ir.ieecas.cn/handle/361006/5430]  
专题地球环境研究所_粉尘与环境研究室
作者单位1.Chinese Acad Sci, Inst Earth Environm, Key Lab Aerosol Chem & Phys, Xian 710061, Peoples R China
2.Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
3.Chinese Acad Sci, Inst Earth Environm, SKLLQG, Xian, Peoples R China
4.Desert Res Inst, Div Atmospher Sci, Reno, NV USA
推荐引用方式
GB/T 7714
Huang, Yu,Cao, Junji,Lee, Shun-Cheng,et al. Challenges on field monitoring of indoor air quality in china[J]. INDOOR AND BUILT ENVIRONMENT,2017,26(4):576-584.
APA Huang, Yu,Cao, Junji,Lee, Shun-Cheng,&Ho, Steven Sai Hang.(2017).Challenges on field monitoring of indoor air quality in china.INDOOR AND BUILT ENVIRONMENT,26(4),576-584.
MLA Huang, Yu,et al."Challenges on field monitoring of indoor air quality in china".INDOOR AND BUILT ENVIRONMENT 26.4(2017):576-584.

入库方式: OAI收割

来源:地球环境研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。