Simultaneous fluorescence and positron emission tomography for in vivo imaging of small animals
文献类型:期刊论文
作者 | Zhang, Bin1; Liu, Shuangquan2; Liu, Fei1; Zhang, Xiaochun3; Xu, Yanyan1; Luo, Jianwen4; Shan, Baoci2; Bai, Jing1 |
刊名 | Journal of biomedical optics
![]() |
出版日期 | 2011-12-01 |
卷号 | 16期号:12页码:3 |
关键词 | Fluorescence imaging Multimodality imaging system Positron emission tomography |
ISSN号 | 1083-3668 |
DOI | 10.1117/1.3665438 |
通讯作者 | Bai, jing(deabj@tsinghua.edu.cn) |
英文摘要 | Simultaneous positron emission tomography (pet) and fluorescence tomography (ft) for in vivo imaging of small animals is proposed by a dual-modality system. this system combines a charge-coupled device-based near-infrared fluorescence imaging with a planar detector pair-based pet. with [f-18]-2-fluoro-2-deoxy-d-glucose radioactive tracer and the protease activated fluorescence probe, on the one hand, the simultaneous metabolic activity and protease activity in tumor region are revealed by the pet and ft, respectively. on the other hand, the protease activity both on the surface layer and the deep tissue of the tumor is provided by the fluorescence reflection imaging and ft, respectively. (c) 2011 society of photo-optical instrumentation engineers (spie). [doi: 10.1117/1.3665438] |
WOS关键词 | SYSTEM ; IMAGER ; PET |
WOS研究方向 | Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging |
WOS类目 | Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging |
语种 | 英语 |
WOS记录号 | WOS:000299490300008 |
出版者 | SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2176149 |
专题 | 高能物理研究所 |
通讯作者 | Bai, Jing |
作者单位 | 1.Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China 2.Chinese Acad Sci, Inst High Energy Phys, Key Lab Nucl Analyt Tech, Beijing 100049, Peoples R China 3.XinAoMDT Technol Co Ltd, Langfang 065001, Peoples R China 4.Tsinghua Univ, Ctr Biomed Imaging Res, Beijing 100084, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Bin,Liu, Shuangquan,Liu, Fei,et al. Simultaneous fluorescence and positron emission tomography for in vivo imaging of small animals[J]. Journal of biomedical optics,2011,16(12):3. |
APA | Zhang, Bin.,Liu, Shuangquan.,Liu, Fei.,Zhang, Xiaochun.,Xu, Yanyan.,...&Bai, Jing.(2011).Simultaneous fluorescence and positron emission tomography for in vivo imaging of small animals.Journal of biomedical optics,16(12),3. |
MLA | Zhang, Bin,et al."Simultaneous fluorescence and positron emission tomography for in vivo imaging of small animals".Journal of biomedical optics 16.12(2011):3. |