中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing

文献类型:期刊论文

作者Wang K(王锴)1,3; Jameson, N. Jordan2; Pecht, Michael2; Guo HF(郭海丰)1,3,4,5; Xu AD(徐皑冬)1,3; Yan BJ(闫炳均)1,3
刊名IEEE Access
出版日期2018
卷号6页码:69860-69868
关键词Precursor-based Prognostics Cyber-physical Systems Electromagnetic Coils Insulation Degradation Monitoring Smart Manufacturing
ISSN号2169-3536
产权排序1
英文摘要

The degradation of key components of production equipment can have adverse effects on manufacturing, such as unexpected machine shutdown and product quality decline. Implementing self-aware component by prognostics and health management (PHM) based cyber-physical systems (CPS) are promising technologies that can address this problem. Considering that electromagnetic coils are fundamental energy conversion and transformation components of a variety of machines, like electric motors and solenoid valves, and their insulation failure can cause catastrophic effects, a precursor-based prognostics method is proposed in this paper to create self-aware low-voltage electromagnetic coils for incipient insulation degradation monitoring. Sensory data to insulation health information conversion and component-cyber interface development for integrating insulation health information to cyber space are described, which present opportunities for developing transparency and thus predictive maintenance of machines that incorporate electromagnetic coils.

WOS关键词EQUIVALENT-CIRCUIT CONCEPT ; RELIABILITY ; ORIGINS ; LIFE
资助项目Natural Science Foundation of China[71661147005] ; Natural Science Foundation of China[71661147005]
WOS研究方向Computer Science ; Engineering ; Telecommunications
语种英语
WOS记录号WOS:000452821700001
源URL[http://ir.sia.cn/handle/173321/23578]  
专题沈阳自动化研究所_工业控制网络与系统研究室
通讯作者Wang K(王锴)
作者单位1.Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China
2.Center for Advanced Life Cycle Engineering, University of Maryland, College Park, MD 20742, USA.
3.Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
4.University of Chinese Academy of Sciences, Beijing 100049, China and Liaoning Institute of Science and Technology, Benxi 117004, China
5.Robotic Drive and Control Engineering Laboratory of Liaoning Province, Liaoning Institute of Science and Technology, Benxi 117004, China
推荐引用方式
GB/T 7714
Wang K,Jameson, N. Jordan,Pecht, Michael,et al. Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing[J]. IEEE Access,2018,6:69860-69868.
APA Wang K,Jameson, N. Jordan,Pecht, Michael,Guo HF,Xu AD,&Yan BJ.(2018).Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing.IEEE Access,6,69860-69868.
MLA Wang K,et al."Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing".IEEE Access 6(2018):69860-69868.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。