Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing
文献类型:期刊论文
作者 | Wang K(王锴)1,3![]() ![]() ![]() ![]() |
刊名 | IEEE Access
![]() |
出版日期 | 2018 |
卷号 | 6页码:69860-69868 |
关键词 | Precursor-based Prognostics Cyber-physical Systems Electromagnetic Coils Insulation Degradation Monitoring Smart Manufacturing |
ISSN号 | 2169-3536 |
产权排序 | 1 |
英文摘要 | The degradation of key components of production equipment can have adverse effects on manufacturing, such as unexpected machine shutdown and product quality decline. Implementing self-aware component by prognostics and health management (PHM) based cyber-physical systems (CPS) are promising technologies that can address this problem. Considering that electromagnetic coils are fundamental energy conversion and transformation components of a variety of machines, like electric motors and solenoid valves, and their insulation failure can cause catastrophic effects, a precursor-based prognostics method is proposed in this paper to create self-aware low-voltage electromagnetic coils for incipient insulation degradation monitoring. Sensory data to insulation health information conversion and component-cyber interface development for integrating insulation health information to cyber space are described, which present opportunities for developing transparency and thus predictive maintenance of machines that incorporate electromagnetic coils. |
WOS关键词 | EQUIVALENT-CIRCUIT CONCEPT ; RELIABILITY ; ORIGINS ; LIFE |
资助项目 | Natural Science Foundation of China[71661147005] ; Natural Science Foundation of China[71661147005] |
WOS研究方向 | Computer Science ; Engineering ; Telecommunications |
语种 | 英语 |
WOS记录号 | WOS:000452821700001 |
源URL | [http://ir.sia.cn/handle/173321/23578] ![]() |
专题 | 沈阳自动化研究所_工业控制网络与系统研究室 |
通讯作者 | Wang K(王锴) |
作者单位 | 1.Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China 2.Center for Advanced Life Cycle Engineering, University of Maryland, College Park, MD 20742, USA. 3.Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China 4.University of Chinese Academy of Sciences, Beijing 100049, China and Liaoning Institute of Science and Technology, Benxi 117004, China 5.Robotic Drive and Control Engineering Laboratory of Liaoning Province, Liaoning Institute of Science and Technology, Benxi 117004, China |
推荐引用方式 GB/T 7714 | Wang K,Jameson, N. Jordan,Pecht, Michael,et al. Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing[J]. IEEE Access,2018,6:69860-69868. |
APA | Wang K,Jameson, N. Jordan,Pecht, Michael,Guo HF,Xu AD,&Yan BJ.(2018).Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing.IEEE Access,6,69860-69868. |
MLA | Wang K,et al."Creating Self-aware Low-Voltage Electromagnetic Coils for Incipient Insulation Degradation Monitoring for Smart Manufacturing".IEEE Access 6(2018):69860-69868. |
入库方式: OAI收割
来源:沈阳自动化研究所
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。