An Improved Oddy Test Using Metal Films
文献类型:期刊论文
作者 | Wu, LM (Wu, Laimin)3,4; Chen, JM (Chen, Jianmin)1; Zhou, XG (Zhou, Xinguang)3,4; An, ZS (An, Zhisheng)2; Kong, LD (Kong, Lingdong); Wang, S (Wang, Sheng)1 |
刊名 | STUDIES IN CONSERVATION
![]() |
出版日期 | 2011 |
卷号 | 56期号:2页码:138-153 |
文献子类 | 期刊论文 |
英文摘要 | The Oddy test is an 'accelerated' corrosion test employed by museums to evaluate the suitability of materials proposed for use in display and storage cases. The standard Oddy test requires a 28-day test period, and the results are assessed by visual observation. This paper describes an improved test method, which could reduce the length of the test period by half The improved method uses metal films as substitutes for the traditional metal coupons posing as 'surrogate art object'. The new test results are then evaluated by computer with digital image processing for more objective selection of less corrosive materials. |
语种 | 英语 |
源URL | [http://ir.ieecas.cn/handle/361006/10316] ![]() |
专题 | 地球环境研究所_古环境研究室 |
推荐引用方式 GB/T 7714 | Wu, LM ,Chen, JM ,Zhou, XG ,et al. An Improved Oddy Test Using Metal Films[J]. STUDIES IN CONSERVATION,2011,56(2):138-153. |
APA | Wu, LM ,Chen, JM ,Zhou, XG ,An, ZS ,Kong, LD ,&Wang, S .(2011).An Improved Oddy Test Using Metal Films.STUDIES IN CONSERVATION,56(2),138-153. |
MLA | Wu, LM ,et al."An Improved Oddy Test Using Metal Films".STUDIES IN CONSERVATION 56.2(2011):138-153. |
入库方式: OAI收割
来源:地球环境研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。