Sequential Injection Approach for Simultaneous Determination ofUltratrace Plutonium and Neptunium in Urine with Accelerator MassSpectrometry
文献类型:期刊论文
作者 | Qiao,JX(Qiao,Jixin)[1]; Xu,YH(Xu,Yihong)[1,4]; Christl,M(Christl,Marcus)[3]; Lachner,J(Lachner,Johannes)[3]; Roos,P(Roos,Per)[1]; Hou,XL(Hou,Xiaolin)[1,2] |
刊名 | analytical chemistry
![]() |
出版日期 | 2013 |
卷号 | 85页码:8826-8833 |
DOI | 10.1021/ac4020319 |
文献子类 | 期刊论文 |
英文摘要 | An analytical method was developed for simultaneous determination of ultratrace level plutonium (Pu) and neptunium (Np) using iron hydroxide coprecipitation in combination with automated sequential injection extraction chromatography separation and accelerator mass spectrometry (AMS) measurement. Several experimental parameters affecting the analytical performance were investigated and compared including sample preboiling operation, aging time, amount of coprecipitating reagent, reagent for pH adjustment, sedimentation time, and organic matter decomposition approach. The overall analytical results show that preboiling and aging are important for obtaining high chemical yields for both Pu and Np, which is possibly related to the aggregation and adsorption behavior of organic substances contained in urine. Although the optimal condition for Np and Pu simultaneous determination requires 5-day aging time, an immediate coprecipitation without preboiling and aging could also provide fairly satisfactory chemical yields for both Np and Pu (50−60%) with high sample throughput (4 h/sample). Within the developed method, 242Pu was exploited as chemical yield tracer for both Pu and Np isotopes. 242Pu was also used as a spike in the AMS measurement for quantification of 239Pu and 237Np concentrations. The results show that, under the optimal experimental condition, the chemical yields of 237Np and 242Pu are nearly identical, indicating the high feasibility of 242Pu as a nonisotopic tracer for 237Np determination in real urine samples. The analytical method was validated by analysis of a number of urine samples spiked with different levels of 237Np and 239Pu. The measured values of 237Np and 239Pu by AMS exhibit good agreement (R2 ≥ 0.955) with the spiked ones confirming the reliability of the proposed method. |
语种 | 英语 |
源URL | [http://ir.ieecas.cn/handle/361006/10880] ![]() |
专题 | 地球环境研究所_加速器质谱中心 |
通讯作者 | Qiao,JX(Qiao,Jixin)[1] |
作者单位 | 1.Center for Nuclear Technologies, Technical University of Denmark, DTU Risø Campus, DK-4000 Roskilde, Denmark; 2.The Key Laboratory of Coastal and Island Development of Ministry of Education, Nanjing University, Nanjing 210093, China 3.Laboratory of Ion Beam Physics, ETH-Zurich, CH-8093 Zurich, Switzerland; 4.Institute of Earth Environment, Chinese Academy of Sciences, Xi’an, China; |
推荐引用方式 GB/T 7714 | Qiao,JX,Xu,YH,Christl,M,et al. Sequential Injection Approach for Simultaneous Determination ofUltratrace Plutonium and Neptunium in Urine with Accelerator MassSpectrometry[J]. analytical chemistry,2013,85:8826-8833. |
APA | Qiao,JX,Xu,YH,Christl,M,Lachner,J,Roos,P,&Hou,XL.(2013).Sequential Injection Approach for Simultaneous Determination ofUltratrace Plutonium and Neptunium in Urine with Accelerator MassSpectrometry.analytical chemistry,85,8826-8833. |
MLA | Qiao,JX,et al."Sequential Injection Approach for Simultaneous Determination ofUltratrace Plutonium and Neptunium in Urine with Accelerator MassSpectrometry".analytical chemistry 85(2013):8826-8833. |
入库方式: OAI收割
来源:地球环境研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。