Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy by an internal reference method

文献类型:期刊论文

作者Sun LX(孙兰香); Yu HB(于海斌)
刊名Talanta
出版日期2009
卷号79期号:2页码:388-395
关键词LIBS Self-absorption Internal reference Calibration-free quantitative analysis Boltzmann plot
ISSN号0039-9140
产权排序1
通讯作者于海斌
中文摘要A simplified procedure for correcting self-absorption effect was proposed in calibration-free laser-induced breakdown spectroscopy (CF-LIBS). In typical LIBS measurement conditions, the plasma produced is often optically thick, especially for the strong lines of major elements. The selection of self-absorption lines destroys the performance of CF-LIBS, and the familiar correction method based on the curve of growth is complex in implementation. The procedure we proposed, named internal reference for self-absorption correction (IRSAC), first chose an internal reference line for each species, then compared other spectral line intensity of the same species with the reference line to estimate the self-absorption degrees of other spectral lines, and finally achieved an optimal correction by a regressive algorithm. The self-absorption effect of the selected reference line can be ignored, since the reference line with high excitation energy of the upper level is slightly affected by the self-absorption. Through the IRSAC method, the points on the Boltzmann plot become more regular, and the evaluations of the plasma temperature and material composition are more accurate than the basic CF-LIBS.
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
关键词[WOS]QUANTITATIVE ELEMENTAL ANALYSIS ; INDUCED PLASMA SPECTROSCOPY ; STEEL ; SPECTROMETRY ; TECHNOLOGY ; MATRIX ; WATER ; MELTS
收录类别SCI ; EI
语种英语
WOS记录号WOS:000268216900044
公开日期2012-05-29
源URL[http://ir.sia.cn/handle/173321/7069]  
专题沈阳自动化研究所_工业信息学研究室
推荐引用方式
GB/T 7714
Sun LX,Yu HB. Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy by an internal reference method[J]. Talanta,2009,79(2):388-395.
APA Sun LX,&Yu HB.(2009).Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy by an internal reference method.Talanta,79(2),388-395.
MLA Sun LX,et al."Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy by an internal reference method".Talanta 79.2(2009):388-395.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。