A method to deal with installation errors of wearable accelerometers for human activity recognition

文献类型:期刊论文

作者Jiang M(姜鸣); Shang H(尚红); Wang ZL(王哲龙); Li HY(李洪谊); Wang YC(王越超)
刊名PHYSIOLOGICAL MEASUREMENT
出版日期2011
卷号32期号:3页码:347-358
关键词Human Activity Recognition Accelerometer Installation Error Calibration Gram-schmidt Orthonormalization
ISSN号0967-3334
产权排序3
英文摘要

Human activity recognition (HAR) by using wearable accelerometers has gained significant interest in recent years in a range of healthcare areas, including inferring metabolic energy expenditure, predicting falls, measuring gait parameters and monitoring daily activities. The implementation of HAR relies heavily on the correctness of sensor fixation. The installation errors of wearable accelerometers may dramatically decrease the accuracy of HAR. In this paper, a method is proposed to improve the robustness of HAR to the installation errors of accelerometers. The method first calculates a transformation matrix by using Gram-Schmidt orthonormalization in order to eliminate the sensor's orientation error and then employs a low-pass filter with a cut-off frequency of 10 Hz to eliminate the main effect of the sensor's misplacement. The experimental results showed that the proposed method obtained a satisfactory performance for HAR. The average accuracy rate from ten subjects was 95.1% when there were no installation errors, and was 91.9% when installation errors were involved in wearable accelerometers.

WOS关键词TRIAXIAL ACCELEROMETER ; ENERGY-EXPENDITURE ; HUMAN MOVEMENT ; CLASSIFICATION ; ALGORITHM ; SENSORS
WOS研究方向Biophysics ; Engineering ; Physiology
语种英语
WOS记录号WOS:000288510200008
资助机构This work was partially supported by National High Technology Research and Development Program 863 grant no 2007AA041502, China Postdoctoral Science Foundation grant no 20080441102, and China Earthquake Research Funds grant no 200808075.
公开日期2012-05-29
源URL[http://ir.sia.cn/handle/173321/7278]  
专题沈阳自动化研究所_机器人学研究室
作者单位1.Shenyang Institute of Automation, Chinese Academy of Science, Shenyang, Liaoning, People’s Republic of China
2.School of Control Science and Engineering, Dalian University of Technology, Dalian, Liaoning, People’s Republic of China
3.Technical Division, National Earthquake Response Support Service, Beijing, People’s Republic of China
推荐引用方式
GB/T 7714
Jiang M,Shang H,Wang ZL,et al. A method to deal with installation errors of wearable accelerometers for human activity recognition[J]. PHYSIOLOGICAL MEASUREMENT,2011,32(3):347-358.
APA Jiang M,Shang H,Wang ZL,Li HY,&Wang YC.(2011).A method to deal with installation errors of wearable accelerometers for human activity recognition.PHYSIOLOGICAL MEASUREMENT,32(3),347-358.
MLA Jiang M,et al."A method to deal with installation errors of wearable accelerometers for human activity recognition".PHYSIOLOGICAL MEASUREMENT 32.3(2011):347-358.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。