中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Unilateral percutaneous kyphoplasty for lumbar spine A comparative study between transverse process-pedicle approach and conventional transpedicular approach

文献类型:期刊论文

作者Wang HW(王洪伟)1,2,3; Hu, Pan2,4; Xu, Weijie2; Feng, Ying2; Zhang, Yan2; Zhu, Yunpeng2; Ren, Weijian2; Xiang LB(项良碧)2
刊名MEDICINE
出版日期2020
卷号99期号:17页码:1-5
关键词lumbar osteoporotic vertebral compression fracture percutaneous kyphoplasty transverse process unilateral
ISSN号0025-7974
产权排序1
英文摘要

Anatomical differences of unilateral percutaneous kyphoplasty (PKP) between transverse process-pedicle approach (TPPA) and conventional transpedicular approach (CTPA) are not well discussed. To investigate the anatomical distinctions of unilateral PKP between TPPA and CTPA, we have discussed the unilateral PKP through a 3-dimensional-computed tomography database. Five hundred lumbar spines from 100 patients have been retrospectively collected and unilateral CTPA and TPPA were simulated. Distance between the entry point and the midline of the vertebral body (DEM), the puncture inclination angle (PIA), and the success rate (SR) of puncture were measured and compared. The male presented with significantly larger DEM than the female. The TPPA group presented with larger DEM than the CTPA group according to different level, the difference was 1.5 +/- 1.1 mm to 3.8 +/- 2.3 mm. The PIAs in the TPPA group were larger than that in the CTPA group. The SR including 1 side SR and bilateral SR was 72.0% in the CTPA group and 98.0% in the TPPA group. Compared with CTPA group, the SR in TPPA group was significantly higher for L1 to L4 no matter in the left, right side and female patients. The TPPA group presented with more lateral entry point, larger PIAs and higher SRs than that in the CTPA group. PKP surgery through a TPPA was safer and could provide a more symmetrical distribution of bone cement than the CTPA group.

WOS关键词VERTEBRAL COMPRESSION FRACTURES ; BALLOON KYPHOPLASTY ; VERTEBROPLASTY ; METAANALYSIS ; EFFICACY
资助项目China Postdoctoral Science Foundation ; Liaoning Provincial Natural Science Foundation of China[2019ZD-1032] ; Foundation of State Key Laboratory of Robotics[2017-O01]
WOS研究方向General & Internal Medicine
语种英语
WOS记录号WOS:000544715800036
资助机构China Postdoctoral Science FoundationChina Postdoctoral Science Foundation ; Liaoning Provincial Natural Science Foundation of China [2019ZD-1032] ; Foundation of State Key Laboratory of Robotics [2017-O01]
源URL[http://ir.sia.cn/handle/173321/27339]  
专题沈阳自动化研究所_机器人学研究室
通讯作者Wang HW(王洪伟)
作者单位1.State Key Laboratory of Materials Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan, Hubei
2.Department of Orthopedics, General Hospital of Northern Theater Command of Chinese PLA
3.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Science, Shenyang, Liaoning
4.Department of Orthopedics, Chinese Medicine Hospital of Dianjiang County, Dianjiang, Chongqing, China
推荐引用方式
GB/T 7714
Wang HW,Hu, Pan,Xu, Weijie,et al. Unilateral percutaneous kyphoplasty for lumbar spine A comparative study between transverse process-pedicle approach and conventional transpedicular approach[J]. MEDICINE,2020,99(17):1-5.
APA Wang HW.,Hu, Pan.,Xu, Weijie.,Feng, Ying.,Zhang, Yan.,...&Xiang LB.(2020).Unilateral percutaneous kyphoplasty for lumbar spine A comparative study between transverse process-pedicle approach and conventional transpedicular approach.MEDICINE,99(17),1-5.
MLA Wang HW,et al."Unilateral percutaneous kyphoplasty for lumbar spine A comparative study between transverse process-pedicle approach and conventional transpedicular approach".MEDICINE 99.17(2020):1-5.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。