ORBSLAM combined with electromagnetic tracking in duodenum 3D reconstruction
文献类型:会议论文
作者 | Zou Y(邹研)1,2,3; Yang YM(杨永明)2,3,4![]() ![]() ![]() |
出版日期 | 2021 |
会议日期 | July 27-31, 2021 |
会议地点 | Jiaxing, China |
页码 | 717-722 |
英文摘要 | Accurate three-dimensional reconstruction of duodenum is very important in the navigation of ERCP surgery, which helps to improve the success rate of chathete-rization and reduce the difficulty of surgery. Due to the narrow anatomical space of the duodenum, the structure is tortuous, the surface is smooth with few texture features. The existing three-dimensional reconstruction and positioning methods still cannot achieve an effective performance. In this paper, the combination of electromagnetic sensing and ORBSLAM is used for the three-dimensional reconstruction of the duodenal biliary and pancreatic duct. First, we use the accurate tracking performance of electromagnetic sensors to improve the effectiveness of SLAM mapping. Second, we replaced the pose estimation of the camera in SLAM with electromagnetic sensing real-Time pose, which improved the real-Time performance of 3D reconstruction. The effectiveness and real-Time performance of the algorithm in the three-dimensional reconstruction of the duodenum, biliary and pancreatic regions are verified through high-simulation models and real clinical video sequences. © 2021 IEEE. |
源文献作者 | IEEE Robotics and Automation Society ; Shenyang Institute of Automation CAS ; Shenzhen Academy of Robotics |
产权排序 | 1 |
会议录 | 2021 IEEE 11th International Conference on CYBER Technology in Automation, Control, and Intelligent Systems, CYBER 2021
![]() |
会议录出版者 | IEEE |
会议录出版地 | New York |
语种 | 英语 |
ISSN号 | 2642-6633 |
ISBN号 | 978-1-6654-2527-8 |
源URL | [http://ir.sia.cn/handle/173321/29940] ![]() |
专题 | 沈阳自动化研究所_机器人学研究室 |
通讯作者 | Liu H(刘浩) |
作者单位 | 1.School of Information Science and Engineering, Shenyang University of Technology, Shenyang, China 2.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China 3.Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China 4.Key Laboratory of Minimally Invasive Surgical Robot, Liaoning Province, China 5.School of Fundamental Sciences, China Medical University, Shenyang, China |
推荐引用方式 GB/T 7714 | Zou Y,Yang YM,Wang CY,et al. ORBSLAM combined with electromagnetic tracking in duodenum 3D reconstruction[C]. 见:. Jiaxing, China. July 27-31, 2021. |
入库方式: OAI收割
来源:沈阳自动化研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。