英文摘要

Uncooled infrared images typically suffer from column fixed-pattern noise (FPN), which is introduced by the non-uniformity of the column-parallel readout circuit. It is a challenging task to remove column FPN without introducing stripe artifacts near strong vertical edges. In this paper, we introduce a novel single-frame-based algorithm to accurately correct column FPN. The algorithm contains two 1D filters. First, a 1D weighted least-squares filter is applied to perform edge-preserving filtering in the horizontal direction to obtain a coarse estimation of the clear scene. Then, a local weighted ridge regression is performed between the horizontal smoothed image and the raw infrared image in vertical direction to refine this estimation. Through an analysis on the cause of stripe artifacts, the proposed non-uniformity correction (NUC) algorithm is proved to be effective in eliminating this problem. The performance of our proposed algorithm is thoroughly investigated and compared to four state-of-the-art single-frame-based destriping methods using both simulated and real experiments.

WOS关键词NONUNIFORMITY CORRECTION ; STRIPE NOISE ; REMOVAL ; IMAGES
WOS研究方向Optics
语种英语
WOS记录号WOS:000497969100016
源URL[http://ir.sia.cn/handle/173321/25883]  
专题沈阳自动化研究所_光电信息技术研究室
通讯作者Zhao YH(赵耀宏)
作者单位1.University of Chinese Academy of Sciences, Beijing 100049, China
2.Key Laboratory of Image Understanding and Computer Vision, Shenyang, Liaoning 110016, China
3.Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, Liaoning 110016, China
4.Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, Liaoning 110169, China
5.Key Laboratory of Opto-Electronic Information Process, Shenyang, Liaoning 110016, China
推荐引用方式
GB/T 7714
Li FZ,Zhao YH,Xiang W. Single-frame-based column fixed-pattern noise correction in an uncooled infrared imaging system based on weighted least squares[J]. Applied Optics,2019,58(33):9141-9153.
APA Li FZ,Zhao YH,&Xiang W.(2019).Single-frame-based column fixed-pattern noise correction in an uncooled infrared imaging system based on weighted least squares.Applied Optics,58(33),9141-9153.
MLA Li FZ,et al."Single-frame-based column fixed-pattern noise correction in an uncooled infrared imaging system based on weighted least squares".Applied Optics 58.33(2019):9141-9153.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。