中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Novel Design for Centrifugal Counter-Current Chromatography: VI. Ellipsoid Column

文献类型:期刊论文

作者Gu, DY (Gu, Dongyu); Yang, Y (Yang, Yi); Xin, XL (Xin, Xuelei); Aisa, HA (Aisa, Haji Akber); Ito, Y (Ito, Yoichiro)
刊名JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES
出版日期2015
卷号38期号:1页码:68-73
关键词rotary-seal-free centrifuge hydrostatic counter-current chromatographic system centrifugal counter-current chromatography retention of the stationary phase protein separation peak resolution ellipsoid column
ISSN号1082-6076
中文摘要A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v/v) (BAW), hexane-ethyl acetate-methanol-0.1M HCl (1:1:1:1, v/v/v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0 degrees column angle (column axis parallel to the centrifugal force) than at 90 degrees column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07mL/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-beta-ala peaks and 1.81 between DNP-beta-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03mL/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.
收录类别SCI
资助信息China National Funds for Distinguished Young Scientists;West Light Foundation of The Chinese Academy of Sciences;Major State Basic Research Development Program
公开日期2015-03-11
源URL[http://ir.xjipc.cas.cn/handle/365002/4209]  
专题新疆理化技术研究所_省部共建新疆特有药用资源利用重点实验室
新疆理化技术研究所_资源化学研究室
作者单位NHLBI, Lab Bioseparat Technol, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Key Lab Xinjiang Indigenous Med Plants Resource U, Urumqi, Peoples R China;Dalian Ocean Univ, Sch Marine Sci & Environm Engn, Dalian, Peoples R China
推荐引用方式
GB/T 7714
Gu, DY ,Yang, Y ,Xin, XL ,et al. Novel Design for Centrifugal Counter-Current Chromatography: VI. Ellipsoid Column[J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES,2015,38(1):68-73.
APA Gu, DY ,Yang, Y ,Xin, XL ,Aisa, HA ,&Ito, Y .(2015).Novel Design for Centrifugal Counter-Current Chromatography: VI. Ellipsoid Column.JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES,38(1),68-73.
MLA Gu, DY ,et al."Novel Design for Centrifugal Counter-Current Chromatography: VI. Ellipsoid Column".JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES 38.1(2015):68-73.

入库方式: OAI收割

来源:新疆理化技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。