中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
  • 长春光学精密机械与物... [4]
采集方式
内容类型
  • 会议论文 [4]
发表日期
  • 2010 [4]
学科主题
筛选

浏览/检索结果: 共4条,第1-4条 帮助

限定条件                        
条数/页: 排序方式:
Influence of spacial temperature distribution on high accuracy interferometric metrology 会议论文  OAI收割
2010
作者:  
Yan F.;  Yan F.
收藏  |  浏览/下载:6/0  |  提交时间:2013/03/28
Fabrication and photoluminescence of ZnS: Mn2+ nanowires/ZnO quantum dots/SiO2 heterostructure (EI CONFERENCE) 会议论文  OAI收割
作者:  
Yang L.;  Wang D.;  Wang Y.;  Wang Y.;  Wang Y.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
In this paper  we demonstrated the encapsulation of ZnS: Mn2+ nanowires (NWs) and ZnO quantum dots (QDs) with a layer of mesoporous SiO 2 shell for the purpose of integrating dual emission property into one common nanostructure. The average diameter of ZnS: Mn2+ NWs  ZnO QDs  and ZnS: Mn2+ / ZnO@SiO2 heterostructure was about 10 nm  6 nm  and 22 nm  respectively. Within ZnS: Mn2+ / ZnO@SiO 2 nanocomposites  the intensity of the yellow-orange emission contributed by ZnS: Mn2+ NWs and the UV emission contributed by ZnO QDs was three and ten times higher than their individual components  respectively. The fluorescence intensity ratio of the dual emission can be tuned by adjusting the hydrolysis time of tetraethyl orthosilicate. The peak energy of the yellow-orange and UV emission showed blueshift and redshift as increasing the temperature  respectively. The anomalous enhancement of the integrated intensity for the UV emission with the temperature indicated that the high surface state density existing in ZnO QDs can overrun the influence of temperature quenching and even alter the photoluminescent properties. 2010 American Institute of Physics.  
Temperature gradients effect on surface test with high precise interferometer 会议论文  OAI收割
2010
Miao E. L.; Gu Y. Q.; Zhang J. A.; Sui Y. X.; Yang H. J.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/28
Influence of spatial temperature distribution on high accuracy interferometric metrology (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Yang H.;  Zhang J.;  Zhang J.;  Zhang J.;  Yan F.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
We calculate the influence of temperature change on the refractive index of air  establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First  a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air  followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer  accompanied by a temperature change random function within each grid. Finally  all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position  angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result  the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus  to realize the high accuracy figure metrology  the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer. 2010 Copyright SPIE - The International Society for Optical Engineering.