An all-optical parallel scheme for the exclusive-or operation
期刊论文
OAI收割
OPTICS COMMUNICATIONS, 2012, 卷号: 285, 页码: 3281-3283
作者:
Song, Q.
;
Cai, P.
;
Wang, P. X.
  |  
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2018/05/31
Exclusive-or operation
All-optical parallel
Polarization analyzer
Coherent light
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.
Transceiving protocol designc for a free space optical communication system (EI CONFERENCE)
会议论文
OAI收割
2008 International Conference on Optical Instruments and Technology: Optical Systems and Optoelectronic Instruments, November 16, 2008 - November 19, 2008, Beijing, China
Hualong W.
;
Wanxin S.
;
Zhongbao X.
收藏
  |  
浏览/下载:58/0
  |  
提交时间:2013/03/25
A new transceiving protocol is demonstrated for a Free Space Optical (FSO) communication system
and it's discussed in two parts: the transmitting protocol and the receiving protocol. During the discussion of these two parts
the cooperation of them is also discussed. Different from wired communication
an FSO system modulates the data on a narrow beam of laser transmitting through the free space or the atmosphere
and the protocol presented in this paper is mainly optimized for terrestrial Free Space Optical links
in which the signal channel of the system is mainly the atmosphere. Due to the complex composition and activity of the atmosphere
this signal channel brings in great influence on the transmitting laser in it
for example
the absorption and scattering of the atmosphere molecules and aerosols
the scintillation of received laser power caused by the turbulence of the atmosphere
all of which results in a much higher Bit Error Rate (BER) of the communication system. Thus in designing a protocol for an FSO system
more effort should be taken in the encoding of the data stream
the synchronization of the data stream
error checking and exception handling. The main function of the transmitting protocol includes interfacing the outer input data with a parallel port
buffering the input data
encoding the input data stream
serializing the parallel data and output the serialized data. It also has an output management unit to manage the activity of each part of the transmitting protocol. The main function of the receiving protocol includes filtering and synchronizing the input serial data stream
paralleling the serial data stream
decoding the input data
error checking
exception handling and interfacing the outer receiver with a parallel port. The entire transceiving protocol could be programmed into a single FPGA chip to improve system integrity and reduce the system cost. The presented protocol could be taken as "protocol transparent" for outer interfaces
meaning that when interfacing the presented system to an outer system
you don't have to consider what protocol the outer system transceiving data stream is under
for example
the TCP/IP protocol or anything else
in the case that its I/O interface is a parallel port. Simulation and final experiment prove that the protocol presented is working fine at a certain bit rate scale. 2009 SPIE.
Research of automatic test technology of parameters used in a dual-CCD TV measure-system (EI CONFERENCE)
会议论文
OAI收割
2nd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 2, 2005 - November 5, 2005, Zian, China
作者:
Wang L.
;
Li Y.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
This paper describes a kind of automatic test technology of the parameters used in a dual-CCD TV measure-system (TV -MS) .The TV -MS is the ground control equipment of the anti-tank missile and integrates the technologies of optical
machine and electronics. It is important and key component. The main technical parameters of the TV -MS are field of view
zero point
precision
sensitivity
anti-jamming ability
zooming time and focus time
etc. To insure the TV -MS satisfying the tactical and technical requirements and discover fault and reason
a fast and accurate equipment satisfying the test technical parameters of the TV -MS is urgently needed in manufacture and service. Firstly
the parameter test system converted optical signal to electronic signal
implemented automatic control of the invariant illumination of parallel pipeline output. Secondly
data and command delivering
displaying or printing are realized by using 80C196KB. The experiment result shows that the approach of automatic testing of the Parameters used in a dual-CCD TV -MS is successful and it can be used for all tests of the functions and parameters of the TV -MS. The main innovations are to realize the fast
veracious measure of technical parameters of the dual-CCD TV-MS
and integrate the technologies of optics
machineries and electronics. An advanced means is provided to judge the technical states
find malfunctions and discover the reasons in producing and maintaining process. The equipment suited for anti-tank missile systems is given.