中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共18条,第1-10条 帮助

条数/页: 排序方式:
First-principles study of helium-vacancy complexes in Be12Ti 期刊论文  OAI收割
PHYSICS LETTERS A, 2022, 卷号: 424, 页码: 6
作者:  
Zhu, Xiaolu;  Zhang, Yaowen;  Tang, Wei;  Meng, Zhaocang;  Li, Wentao
  |  收藏  |  浏览/下载:64/0  |  提交时间:2022/04/11
First-principles study of hydrogen-vacancy complexes in Be12Ti 期刊论文  OAI收割
JOURNAL OF NUCLEAR MATERIALS, 2019, 卷号: 525, 页码: 7-13
作者:  
Zhu, Xiaolu;  Wang, Canglong;  Meng, Zhaocang;  Wang, Yinlong;  Deng, Huiqiu
  |  收藏  |  浏览/下载:73/0  |  提交时间:2019/11/10
A New Set of Parameters of High-Mass X-ray Binaries Found with their Cyclotron Lines 期刊论文  OAI收割
arXiv e-prints, 2018
作者:  
Zhang, Chengmin;  Taani, Ali;  Chaty, Sylvain;  Karino, Shigeyuki;  Song, Liming
  |  收藏  |  浏览/下载:75/0  |  提交时间:2019/07/12
Astrophysics - High Energy Astrophysical Phenomena  Abstract: We have derived new physical quantities for several High-Mass X-ray Binaries (HMXBs) with supergiant (SG) companions through their cyclotron lines. The parameters are: the terminal velocity of the wind, the mass loss rate of the donor, the effective temperature and the magnetic fields. These parameters influence significantly the improvement of the model of accretion. In spite of the variety of their observational properties, the corresponding magnetic field is around B ~ 10^12 G. This result can be constrained by the effects on stellar evolution. In addition, we have performed a segmentation in the parameter space of donors intended for several SG-HMXB listed in our sample set. The parameter space can be categorized into five regimes depending on the possibility of disk formation associated with accretion from the stellar wind. This can give a quantitative clarification of the observed variability and the properties of these objects. We show that, when these systems come into the direct accretion region, systems with corresponding parameters can emit X-rays.  
奇异核(~(12,14)Be、~8B)核物质密度分布的提取及其应用 学位论文  OAI收割
博士: 中国科学院研究生院(上海应用物理研究所), 2014
蔡晓鹭
收藏  |  浏览/下载:36/0  |  提交时间:2015/03/13
A method for determination of the s orbital component of Be-12 ground state 期刊论文  OAI收割
NUCLEAR SCIENCE AND TECHNIQUES, 2014, 卷号: 25, 期号: 2
Cai, XL; Fan, GW; Xu, HH; An, ZD; Fan, GT; Xu, BJ; Li, YJ; Pan, QY; Yan, Z; Xu, W
收藏  |  浏览/下载:42/0  |  提交时间:2015/03/13
Experimental study on formability of bulk metallic glass as mold for microstructure replication (EI CONFERENCE) 会议论文  OAI收割
作者:  
Liu J.;  Lin J.;  Huang Y.;  Liu J.;  Liu J.
收藏  |  浏览/下载:48/0  |  提交时间:2013/03/25
La62Al14Cu12Ni12BMG is introduced as a substitute for silicon which was widely used as mold material for nanofabrication. For the purpose of precise microstructure replication and complete filling  effects of various imprint parameters  including imprint temperature  imprint time and compression load  on formability of La 62Al14Cu12Ni12BMG are studied and discussed. Scanning electron microscope images and results of thermal analysis are used to characterize the filling effect of La62Al 14Cu12Ni12BMG. In particular  correlations between time and thermodynamic properties are presented. Despite of its high viscosity at crystallization temperature and its narrow supercooled liquid region  La62Al14Cu12Ni12BMG is proved to be a durable and promising material which can precisely replicate the patterns of silicon mold and then transfer its own patterns on Ce 69Al10Cu20Co1BMG and PMMA. 2012 Elsevier B.V. All rights reserved.  
Energy transfer in Y3Al5O12:Ce 3, Pr3+ and CaMoO4:Sm3, Eu 3 phosphors (EI CONFERENCE) 会议论文  OAI收割
作者:  
Wang L.;  Wang X.-J.;  Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:36/0  |  提交时间:2013/03/25
Non-radiative energy transfers (ET) from Ce3 to Pr3+ in Y3Al5O12:Ce3  Pr3+ and from Sm3 to Eu3 in CaMoO4:Sm3  Eu3 are studied based on photoluminescence spectroscopy and fluorescence decay patterns. The result indicates an electric dipoledipole interaction that governs ET in the LED phosphors. For Ce3 concentration of 0.01 in YAG:Ce3  Pr3+  the rate constant and critical distance are evaluated to be 4.510-36 cm 6 s-1 and 0.81 nm  respectively. An increase in the red emission line of Pr3+ relative to the yellow emission band of Ce 3  on increasing Ce3 concentration is observed. This behavior is attributed to the increase of spectral overlap integrals between Ce3 emission and Pr3+ excitation due to the fact that the yellow band shifts to the red spectral side with increasing Ce3 concentration. In CaMoO4:Sm3  Eu3  Sm 3Eu3 transfer occurs from 4G5/2 of Sm3 to 5D0 of Eu3. The rate constant of 8.510-40 cm6 s-1 and the critical transfer distance of 0.89 nm are evaluated. 2010 Elsevier B.V. All rights reserved.  
Preparation, microstructure and deformation behavior of Zr-based metallic glass/porous SiC interpenetrating phase composites 期刊论文  OAI收割
Materials Science and Engineering a-Structural Materials Properties Microstructure and Processing, 2011, 卷号: 530, 页码: 15-20
Y. L. Chen; A. M. Wang; H. M. Fu; Z. W. Zhu; H. F. Zhang; Z. Q. Hu; L. Wang; H. W. Cheng
收藏  |  浏览/下载:38/0  |  提交时间:2012/04/13
Design of driving circuit for binocular CCD image system (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
The paper designs a driving circuit of high sensitive  wide dynamic and high signal-to-noise ratio for binocular CCD imaging system which adopts a Dalsa-made high resolution full-frame 33-mega pixels area CCD FTF5066M. Inner structure and driving timing of the FTF5066M sensor are presented. Field Programmable Gate Array (FPGA) is used as the main device to accomplish the timing design of the circuits and power driver control of the two sensors. By using the Correlated Double Sampling (CDS) technique  the video noise is reduced and the SNR of the system is increased. A 12- bit A/D converter is used to improve the image quality. The output rate of the imaging system designed with integrated chip can reach to 1.3 frames per second through bi-channel. For its good performance  low power consumption and small volume  the driving system can be applied to aeronautics and astronautics field. With a further improvement  a maximum data output rate of 2.7 frames per second can be reached through all the eight channels of the two CCDs. 2010 Copyright SPIE - The International Society for Optical Engineering.  
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Song K.-F.;  Li J.-L.;  Zhang W.-L.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.