中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
沈阳自动化研究所 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2020 [1]
2006 [1]
2005 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
提交时间升序
提交时间降序
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
Evaluating methods for quality of laser shock processing
期刊论文
OAI收割
Optik, 2020, 卷号: 200, 页码: 1-10
作者:
Wu JJ(吴嘉俊)
;
Zhao JB(赵吉宾)
;
Qiao HC(乔红超)
;
Zhang YN(张旖诺)
;
Hu XL(胡宪亮)
  |  
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2019/10/10
Laser shock processing
Surface modification
Development status
Evaluating methods
Analysis of a precise instrument for measuring reference level involute (EI CONFERENCE)
会议论文
OAI收割
Third International Symposium on Precision Mechanical Measurements, August 2, 2006 - August 6, 2006, Xinjiang, China
作者:
Zhang Y.
;
Wang X.
;
Wang X.
;
Wang X.
;
Wang L.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
Reference level involute is used for evaluating other involutes
but it is very difficult to measure reference level involute exactly. Nowadays the available methods for measuring precise involute include single base disc mode
electronic generation mode
and CNC three-coordinate mode. But measurement accuracy of the modes above is not suitable for reference level involute. A precise instrument for measuring reference level involute
double base discs instrument
is introduced. It is consistent with generation principle of the involute entirely. Besides having the advantages of single basic disc instrument
the instrument can remove Abbe error caused by the stylus
and has no pressure deforming. The instrument's structure is described. The main sources of measurement errors are analyzed and methods for compensation are presented. Finally
uncertainty of the instrument is given
which meets reference level involute test specification.
Imaging quality analysis of KBA x-ray microscope working at grazing incidence (EI CONFERENCE)
会议论文
OAI收割
Optical Design and Testing II, November 8, 2004 - November 11, 2004, Beijing, United states
作者:
Zhao L.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
In the latest 20 years
x-ray imaging technology has developed fast in order to meet the need of x-ray photo-etching
spatial exploration technology
high-energy physics
procedure diagnosis of inertial confinement fusion (ICF) et al. Since refractive index of materials in the x-ray region is lower than 1
and x-ray is strongly absorbed by materials
it is very difficult to image objects in the x-ray region. Conventional imaging methods are hardly suitable to x-ray range. In general
grazing reflective imaging and coding aperture imaging methods have been adopted more and more. In this paper
according to user's requirement
we have designed a non-coaxial grazing KBA microscope. The microscope consists of two sets of perpendicular spherical mirrors
each set includes two parallel mirrors. Taking it as an example
we have compiled an optical computing program for the non-coaxial grazing imaging systems so as to analyze and evaluate aberrations of KBA microscope. Thus it can help us to get an optimal comprehension of KBA x-ray imaging system. In the same time
the analytical results provide reliable foundation for evaluating imaging quality of KBA microscope.