中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共9条,第1-9条 帮助

条数/页: 排序方式:
Determination of the pressure and composition of wet gas fluid inclusions: An in situ Raman spectroscopic approach 期刊论文  OAI收割
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 卷号: 308, 页码: 11
作者:  
Li, Feiyang;  Wan, Ye;  Sun, Dongquan;  Wang, Xiaolin;  Hu, Wenxuan
  |  收藏  |  浏览/下载:39/0  |  提交时间:2024/02/26
In situ Raman spectroscopic measurement of the 13C/12C ratio in CO2: Experimental calibrations on the effects of fluid pressure, temperature and composition 期刊论文  OAI收割
Chemical Geology, 2023, 卷号: 615, 期号: 2023, 页码: 121201
作者:  
Wenwen Lu;  Xiaolin Wang;  Qian Wan;  Wenxuan Hu;  I-Ming Chou
  |  收藏  |  浏览/下载:20/0  |  提交时间:2023/01/05
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Liu Y.;  Sun Q.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation  the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results  the reference gains and the dynamic range of temperature measurement were obtained. Finally  the uncertainty influencing the calibration results was analyzed  the analysis shows the maximal uncertainty is 5.2%  which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Application of image smoothing algorithm (EI CONFERENCE) 会议论文  OAI收割
2010 3rd International Congress on Image and Signal Processing, CISP 2010, October 16, 2010 - October 18, 2010, Yantai, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
Design of high precision star image locating method used in star sensor technology (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
作者:  
Sun H.;  Wang Y.;  Wang Y.;  Wang Y.;  Wang Y.
收藏  |  浏览/下载:55/0  |  提交时间:2013/03/25
Nowadays star sensor technology used in aircraft attitude measurement has become more and more popular for its high precision  light weight  without attitude accumulation errors and other advantages. In order to enhance the accuracy of star sensor  it is critical to make efforts to promote the precision of star image locating. High precision star image locating method mentioned in this article includes two aspects. One is sub-pixel dividing algorithm used to acquire the coordinate of stars. The other one is imaging calibration method used to weaken the effect caused by imaging distortion. This method is finally realized in some type of star sensor system. Then an experiment is designed to verify the precision of the method. The result of the experiment shows that the precision of the method is 2" in the experimental environment. 2010 IEEE.  
Experimental analysis of accelerometer installation error (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Yanqiu H.; Juan C.; Peng Y. L.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
Linearity measurement for image-intensified CCD (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang L.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Yan F.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)  technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed  and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system  and calibration of the filters' transmittance in different working positions has been done. Meanwhile  to assure the uniform of the received radiation on the target of the detector at any test points  an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization  the attenuation film with transmission  integrating sphere  optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument  the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Dynamic data fixing for IR target radiation characteristics (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Lihua C.; Juan C.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
The main methods to measure the target IR features are the following two ways: test and then measurement  or theoretical and simulation calculation. The former is direct measurement so the results are more accurate but the test is costly and complicated  so that it is limited in the application. Theoretical and simulation calculation are widely used in the target IR radiation calibration. Here we give the basic configuration of the calibration platform for measuring the IR radiation of the large area low temperature blackbody source  and discuss the calibration flowchart and key technologies for atmospheric transmission correction. The dynamic data are analyzed in real time to determine the IR radiation features in the data fusion subsystem  and the experimental results show that the calibration method is feasible and practical. 2010 IEEE.  
Method for recovering dynamic position of photoelectric encoder (EI CONFERENCE) 会议论文  OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 19, 2008 - November 21, 2008, Chengdu, China
作者:  
Sun Y.;  Liu Y.-S.;  Liang L.-H.;  Sun Y.;  Wan Q.-H.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
This paper presents a method to recover dynamic position of photoelectric encoder. While working at dynamic state  original outputs of the photoelectric encoder are in theory two sine or triangular signals with a phase difference of /2. However  there are still deviations of actual output signals. Interpolating on the basis of this deviation signal will result in interpolation errors. In dynamic state  true original signal data obtained by data acquisition system is a time equation. Through processing these data by data equiangular and harmonic analysis  the equation will be converted from time domain to position domain and an original position equation can be formed. Then the interpolation errors also can be obtained. By this method  the interpolation errors can be checked in dynamic state and it can also provide electric interpolation basis so that to improve dynamic interpolation precision of the encoder. Software simulation and experimental analysis all prove the method effective. This method is he basis in theory for precision checking and calibration in motion. 2009 SPIE.