Using Triple Collocation Observations to Estimate Satellite Measurement Noise 期刊论文  OAI收割
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 卷号: 60, 页码: 11
作者:  
Chen, Jun;  Quan, Wenting;  Wang, Kexin;  Han, Qijin;  Liu, Jia
  |  收藏  |  浏览/下载:7/0  |  提交时间:2024/05/07
Using Triple Collocation Observations to Estimate Satellite Measurement Noise 期刊论文  OAI收割
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 卷号: 60, 页码: 11
作者:  
Chen, Jun;  Quan, Wenting;  Wang, Kexin;  Han, Qijin;  Liu, Jia
  |  收藏  |  浏览/下载:7/0  |  提交时间:2024/12/07
Noise reduction technology of TEM using optimization of instrument sampling function 期刊论文  OAI收割
CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2017, 卷号: 60, 期号: 9, 页码: 3677-3684
作者:  
Wu Xin;  Xue Guo-Qiang;  Xiao Pan;  Rao Li-Ting;  Guo Rui
  |  收藏  |  浏览/下载:28/0  |  提交时间:2017/11/24
An improved histogram matching algorithm for the removal of striping noise in optical remote sensing imagery 期刊论文  OAI收割
OPTIK, 2015, 卷号: 126, 期号: 23, 页码: 15536-15560
作者:  
Cao, Biao;  Du, Yongming;  Xu, Daqi;  Li, Hua;  Liu, Qinhuo
收藏  |  浏览/下载:29/0  |  提交时间:2016/04/20
The error analysis of automated biochemical analyzer (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Computing, Information and Control, ICCIC 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Qinghai C.; Yihui W.; Haiwen L.; Peng H.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
Electronic system design of ultraviolet ozone vertical profile probe for aerography satellite (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Song K.; Wang S.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The design of ultraviolet ozone vertical profile probe is illustrated and the electronic system is introduced in detail. The device is a compact  high precision  ultraviolet-vacuum  ultraviolet spectral radiometer  and is used to measure atmospheric solar backscattering spectral radiance and solar spectral irradiance. Noise of the system is analyzed and Numeric accumulation and synchronous demodulation was used to decrease the noise and the zero-drift of the instrument. The solar irradiance at altitude 830 km in 160-400 nm and the backscattering solar spectral radiance in the ultraviolet ozone absorption band at 12 wavelengths from 250 nm to 340 nm are obtained. Test results on orbit show that all the requested function is met successfully and the performance is stable. 2011 IEEE.  
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.  
Using Triple Collocation Observations to Estimate Satellite Measurement Noise 期刊论文  OAI收割
IEEE Transactions on Geoscience and Remote Sensing
作者:  
Chen, Jun;  Quan, Wenting;  Wang, Kexin;  Han, Qijing;  Liu, Jia
  |  收藏  |  浏览/下载:20/0  |  提交时间:2021/04/13