中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
西安光学精密机械研究... [4]
高能物理研究所 [2]
计算技术研究所 [1]
上海光学精密机械研究... [1]
采集方式
OAI收割 [11]
iSwitch采集 [1]
内容类型
期刊论文 [7]
会议论文 [5]
发表日期
2023 [1]
2021 [1]
2018 [2]
2013 [1]
2012 [1]
2011 [5]
更多
学科主题
激光器;半导体激光器 [1]
电子、电信技术::信... [1]
电子、电信技术::计... [1]
筛选
浏览/检索结果:
共12条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Research on a Super-Sub-Arc Bivariate Relative Angle Thermal Deformation Testing Method without Pitch Angle Limitation
期刊论文
OAI收割
APPLIED SCIENCES-BASEL, 2023, 卷号: 13, 期号: 17
作者:
Liu, Yang
;
Xue, Yaoke
;
Wang, Hu
;
Pan, Yue
;
Lin, Shangmin
  |  
收藏
  |  
浏览/下载:77/0
  |  
提交时间:2023/10/08
not limited by pitch angle
thermal deformation
bivariate angle
ultra-sub-arc
position-sensitive device
displacement coordinate analysis algorithm
matrix comparison method
integrated measurement equipment
Limited View Tomographic Reconstruction Using a Cascaded Residual Dense Spatial-Channel Attention Network With Projection Data Fidelity Layer
期刊论文
OAI收割
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 卷号: 40, 期号: 7, 页码: 1792-1804
作者:
Zhou, Bo
;
Zhou, S. Kevin
;
Duncan, James S.
;
Liu, Chi
  |  
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2021/12/01
Tomographic reconstruction
cascaded network
projection data fidelity layer
RedSCAN
limited angle
sparse view
A Joint Reconstruction and Segmentation Method for Limited-Angle X-Ray Tomography
期刊论文
OAI收割
IEEE ACCESS, 2018, 卷号: 6, 页码: 7780-7791
作者:
Wei, L
;
Wei ZH(魏增辉)
;
Liu BD(刘宝东)
;
Wei, ZH
;
Liu, BD
  |  
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2019/09/24
Limited-angle
Mumford-Shah
PCMS
discrete tomography
prior knowledge
A joint reconstruction and segmentation method for limited-angle x-ray tomography
期刊论文
iSwitch采集
Ieee access, 2018, 卷号: 6, 页码: 7780-7791
作者:
Wei, Zenghui
;
Liu, Baodong
;
Dong, Bin
;
Wei, Long
收藏
  |  
浏览/下载:62/0
  |  
提交时间:2019/04/23
Limited-angle
Mumford-shah
Pcms
Discrete tomography
Prior knowledge
LABTM control system based on FPGA (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Mechatronics and Applied Mechanics, ICMAM 2012, December 8, 2012 - December 9, 2012, Taiwan
作者:
Wang Y.
;
Yu P.
;
Yu P.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:153/0
  |  
提交时间:2013/03/25
This paper presents the digital PI control method for design and simulation of a high precision limited angle brushless torque motor control system in Field Programmable Gate Array device (FPGA). The direct drive structures which are widely applied in many servo control fields. Matlab Xilinx System GeneratorR toolbox based on Fixed-Point Arithmetic is used to design the digital PI controller using DSP architecture
plot the responses of the control system and generate the VHDL source code. The control system model consists of a digital PI
a real LABTM
and a real absolute Inductosyn
encoder to rpm and position blocks. Through loading generated codes in process of the simulation that built by the digital discrete model
it is verified that the rising time of current loop is only 1.2ms
and rate loop is 8ms
overshoot is rarely 4.2%. Finally
the comprehensive positioning accuracy of system can reach up to 5 arc sec
and the rate jitter achieves 5% with the 4 arc sec accuracy absolute Inductosyn. (2013) Trans Tech Publications
Switzerland.
Image quality assessment based on complex representation of structure information (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electrical, Information Engineering and Mechatronics, EIEM 2011, December 23, 2011 - December 25, 2011, Jiaozuo, Henan, China
作者:
Wang Y.
;
Wang Y.
;
Wang Y.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
Local variance and single pixel value are combined to describe image structure information using complex method in this paper in order to improve the consistency of objective image assessment result with that of subjective method. The effect of the detail structure information on the image quality was emphasized by this method accordingly. Singular value decomposition was performed on local variance distribution complex matrix. The angle between the singular value vectors of the reference image and the disturbed image was used to measure their structural similarity. Then the quality assessment process was achieved. Results from experiments show that the proposed method is better consistent with human visual system characteristics than MSE
PSNR
and SSIM. 2012 Springer-Verlag London Limited.
Optimization for limited angle tomography in medical image processing
期刊论文
OAI收割
pattern recognition, 2011, 卷号: 44, 期号: 10-11, 页码: 2427-2435
作者:
Lu, Xiaoqiang
;
Sun, Yi
;
Yuan, Yuan
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2011/09/30
Limited angle tomography
Ill-posed inverse problem
Total variation (TV)
Image reconstruction by an alternating minimisation
期刊论文
OAI收割
neurocomputing, 2011, 卷号: 74, 期号: 5, 页码: 661-670
作者:
Lu, Xiaoqiang
;
Sun, Yi
;
Yuan, Yuan
收藏
  |  
浏览/下载:205/60
  |  
提交时间:2011/01/11
Limited angle tomography
III-posed inverse problem
Total variation (TV)
Effect of gimbal point displacement on optical axis pointing precision in an image seeker (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electric Information and Control Engineering, ICEICE 2011, April 15, 2011 - April 17, 2011, Wuhan, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2013/03/25
A concentric glass spherical dome was usually chosen as the transparent window mounted in front of the optical lens in an image seeker. However
optical ray had to change its direction when propagating through the dome due to refraction unless passing through the center of the dome
which demanded gimbal point coincide with the center of the dome exactly. In fact
gimbal point displacement could not be eliminating due to fabrication
assembly and vibration
therefore the optical axis pointing error generated. In this paper
the effect of gimbal point displacement on optical axis pointing precision in an image seeker was analyzed
and the theoretical expression of the optical axis pointing error was derived based on geometric optics
and the error dynamics was explored by numerical. Take a visible light image seeker as a case
the thickness of concentric glass spherical dome was 8mm and the inner radius was 72mm
and the optical axis pointing errors varying dynamically with the look angle and the gimbal point displacement were shown in graph. When the gimbal displacement was 0.11mm
the maximum optical axis pointing error was 0.054mrad that is equal to the instantaneous field of view (IFOV) corresponding to the camera system whose focal length was 120mm and pixel size was 6.5m. Furthermore
with the gimbal displacement increasing
the optical axis pointing error increased linearly. The analyzed results provided a theoretical basis for the displacement range
which had to be limited strictly in the gimbal design process. 2011 IEEE.
Three-sample rotation vector algorithm with angular rate input (EI CONFERENCE)
会议论文
OAI收割
2011 2nd International Conference on Mechanic Automation and Control Engineering, MACE 2011, July 15, 2011 - July 17, 2011, Inner Mongolia, China
作者:
Zhang Y.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
In order to research the attitude algorithm with angular rate input under the conical motion
a optimal threesample rotation vector algorithm based on single-step Newton backward interpolation is proposed. Using the principle of limited rigid body rotation and the characteristic of angular rate input
three-sample rotation vector algorithm is derivated. To minimum attitude errors
three-sample rotation vector algorithm is optimized. Three angular rate extraction methods of singlestep entire sample recursion
multi-step entire sample and singlestep Newton backward interpolation are proposed. Under the condition of conical motion with semi-cone angle 3 and angular frequency 2rad/s
simulation is done. The simulation results show that single-step Newton backward interpolation is superior to the other two methods
and its maximum error peak is 0.01
error drift rate is 0.036/h. Experiments in three-axis flying turntable with the same parameters are carried out
and the results show that error drift rates of three-channels are less than those of traditional quaternion
which are 13.53%
12.08% and 23.68% lower respectively. It also verified that the new algorithm can perform a high accuracy under the conical motion. 2011 IEEE.