消息
×
loading..
中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
_filter
_filter
_filter
筛选

浏览/检索结果: 共4条,第1-4条 帮助

条数/页: 排序方式:
Calibration of Photoelectric Response Characteristics of a Scientific Grade Charge-coupled Device (CCD) Camera Based on Wedge Interference 期刊论文  OAI收割
LASERS IN ENGINEERING, 2018, 卷号: 41, 期号: 43103, 页码: 129-137
作者:  
Lin, H.;  Da, Z-S.
  |  收藏  |  浏览/下载:31/0  |  提交时间:2018/10/23
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Liu Y.;  Sun Q.
收藏  |  浏览/下载:27/0  |  提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation  the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results  the reference gains and the dynamic range of temperature measurement were obtained. Finally  the uncertainty influencing the calibration results was analyzed  the analysis shows the maximal uncertainty is 5.2%  which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Cr image enhancement based on human visual characteristics (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer Design and Applications, ICCDA 2010, June 25, 2010 - June 27, 2010, Qinhuangdao, Hebei, China
Zhang M.-H.; Zhang Y.-Y.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
The characteristic of digital CR medicine radiation image has wide dynamic range  abundant details and bad contrast  so it is necessary to enhance CR image to the need of doctor diagnosis. But the general enhancement algorithms don't consider human visual characteristics  so it puts forward CR medicine image adaptive enhancement algorithm combining the human visual property  which is more sensitive to smooth area noise compared with detail area noise  and makes image edge detail enhancement great in detail area  and detail enhancement little in smooth area  in which factor K is based on space change of image domain  accordingly gaining non-linear enhancement edge details of CR image. Experiment results demonstrate that the algorithm enhances CR image detail and CR image enhanced has good visual effect  so the method is fit for edge detail enhancement of CR medicine radiation image. 2010 IEEE.  
Design of a scene simulator in land-based aerospace lab with the man-made light source system based on quantum theory (EI CONFERENCE) 会议论文  OAI收割
Optoelectronic Devices and Integration II, November 12, 2007 - November 15, 2007, Beijing, China
作者:  
Fang W.;  Yi W.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
The paper presents a method with the technique of combination filtering of spectrum and the technique of DSP control for the simulation and recognition of the spontaneously lightening object and stellar map in the universe. The magnitude and the spectrum of a star can be simulated in a wide dynamic range. We established the mathematical models of the Vega's visible light spectrum and luminous flux density. Tungsten-halogen lamp as a light source is used to fit the linear light of the spontaneously lightening object in the universe. Through the experiment  it shows that the more sub-channels there are while filtering spectrum in the visible spectrum  and the more degrees the variable neutral density filters and the narrow-band attenuators have  more close to the actual spectrum the simulated spectrum is. It is proved that using the PID technique is beneficial to the output of the accurate and steady radiation from the light sources. The experiment shows that the using of this method can get perfect result in fitting and simulating the spectrum  magnitude and the stellar map of the spontaneously lightening object . The analysis of the consistent result and the experimental error is also discussed in detail in this paper.  
  • 首页
  • 上一页
  • 1
  • 下一页
  • 末页