中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [9]
遥感与数字地球研究所 [2]
自动化研究所 [2]
上海光学精密机械研究... [2]
光电技术研究所 [1]
合肥物质科学研究院 [1]
更多
采集方式
OAI收割 [17]
内容类型
会议论文 [9]
期刊论文 [8]
发表日期
2020 [1]
2019 [1]
2018 [3]
2016 [1]
2011 [2]
2010 [5]
更多
学科主题
筛选
浏览/检索结果:
共17条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Traffic Flow Imputation Using Parallel Data and Generative Adversarial Networks
期刊论文
OAI收割
IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2020, 卷号: 21, 期号: 4, 页码: 1624-1630
作者:
Chen, Yuanyuan
;
Lv, Yisheng
;
Wang, Fei-Yue
  |  
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2020/06/02
Generators
Data models
Gallium nitride
Generative adversarial networks
Training
Loss measurement
Biological system modeling
Parallel data
generative adversarial networks
traffic flow imputation
data augmentation
deep learning
Complete kinematic calibration of a 6-RRRPRR parallel kinematic machine based on the optimal measurement configurations
期刊论文
OAI收割
Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science, 2019, 卷号: 234, 期号: 1, 页码: 121-136
作者:
C.Y.Han
;
Y.Yu
;
Z.B.Xu
;
X.M.Wang
;
P.Yu
  |  
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2020/08/24
Parallel kinematic machine,complete error model,observability index,optimal measurement configurations,calibration experiment,identifiable parameters,robot calibration,stiffness,design
Robust Landmark Detection and Position Measurement Based on Monocular Vision for Autonomous Aerial Refueling of UAVs
期刊论文
OAI收割
IEEE TRANSACTIONS ON CYBERNETICS, 2019, 卷号: 49, 期号: 12, 页码: 4167-4179
作者:
Sun, Siyang
;
Yin, Yingjie
;
Wang, Xingang
;
Xu, De
  |  
收藏
  |  
浏览/下载:53/0
  |  
提交时间:2018/10/02
Aerial refueling
landmark detection
monocular vision
multitask parallel deep convolution neural network (MPDCNN)
position measurement
Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor
期刊论文
OAI收割
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 卷号: 38, 期号: 6, 页码: 1982-1986
作者:
Luo Wei
;
Sun Feng-long
;
Liu Jia-rui
;
Hou Jun-wu
;
Wang Ben-gan
  |  
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2019/11/12
Temperature
RI
Matrix measurement
Parallel light path
Surface Plasmon Resonance
Modeling and image motion analysis of parallel complementary compressive sensing imaging system
期刊论文
OAI收割
Optics Communications, 2018, 卷号: 423, 页码: 100-110
作者:
Li, Y. H.
;
Wang, X. D.
;
Wang, Z.
;
Liu, D.
;
Ding, Y.
  |  
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2019/09/17
Computational imaging
Compressive sensing
Parallel measurement
Image
motion
coded-aperture design
reconstruction
information
modulation
Optics
GPU-accelerated phase extraction algorithm for interferograms: A real-time application
期刊论文
OAI收割
Proceedings of SPIE: Optical Metrology and Inspection for Industrial Applications IV, 2016, 卷号: 10023, 页码: 1002327
作者:
Zhu, Xiaoqiang
;
Wu, Yongqian
;
Liu, Fengwei
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2018/06/14
Extraction
Interferometry
Matlab
Parallel Processing Systems
Phase Shift
Smart Cards
Units Of Measurement
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.
A small thickness measurement system based on PSD and FPGA (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:
Guo J.
;
Guo J.
;
He X.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
Considering that the requirement of industrial manufacture
An AT89S51 singlechip works as the core processor of the system. By two laser triangulation
a small thickness measurement system based on PSD and FPGA is presented. It takes S3931 PSD of one dimension as position detection device
A FPGA produces logic control signals for the whole system
the small displacement is converted to differential voltages
which is made by Hamamatsu in Japan
and after amplification and A/D transformation
8-bit parallel data is send to singlechip from FPGA by external interrupts
and the final calculation results output to the LCD display module. After digital micro meter calibration
we get the small thickness. Experiments show that the detection accuracy of the system is not less than 10um.
Station mode for attitude determination of small-multi-target with high speed (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on E-Product E-Service and E-Entertainment, ICEEE2010, November 7, 2010 - November 9, 2010, Henan, China
作者:
Wang J.
;
Zhao L.
;
Li M.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
A key problem of attitude measurement of small-multi-target with high speed is how to decide the optimum of the CMOS stations. A multi-CMOS station mode is designed in this paper
multiple CMOS videos were placed on two parallel sides in measurement system
every two CMOS form an intersection viewing field
multiple viewing field join to cover shooting range
which can augment Effective Viewing Field(EVF)
increase capture ratio of objects with high speed and measurement precision of small objects. When an object passes through the joint area
it will be imaged separately on each CMOS focal plane. Multiple CMOS videos were triggered synchronously
a sequence of image information was extracted
the target attitude was confirmed by digital image processing technology. The merit of station mode is low cost
large measurement scope
extending freely and so on. 2010 IEEE.
Experimental analysis of accelerometer installation error (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Yanqiu H.
;
Juan C.
;
Peng Y. L.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
When accelerometer is installed
errors would be produced
which will greatly degrade the measurement accuracy
so to the tracking precision while being applied in the compound control. We make the experimental analysis for the accelerometer installation
in which the accelerometer is installed parallel to the azimuth and 30 degree away the azimuth. The data are dealt with and compared with the theoretical results. Out work can offer useful information for the calibration of accelerometer in the optoelectronic tracking system. 2010 IEEE.