Laser flat-field system based on light scattering in nano-particle solution
期刊论文
OAI收割
OPTICS AND PRECISION ENGINEERING, 2015, 卷号: 23, 期号: 5, 页码: 1213-1220
作者:
Wang QS(王秋实)
;
Yang FG(杨福桂)
;
Liu DX(刘丁枭)
;
Sheng WF(盛伟繁)
;
Li M(李明)
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2016/04/18
Backscattering light
CCD arrays
Long trace profiler
Nanoparticle solutions
Non-uniform
Polytetrafluoroethylene (PTFE)
Precision instrument
Structure parameter
Application of carbon fibre reinforced plastic for optical camera structure (EI CONFERENCE)
会议论文
OAI收割
2012 9th IEEE International Conference on Mechatronics and Automation, ICMA 2012, August 5, 2012 - August 8, 2012, Chengdu, China
An Y.
;
Yao J.-S.
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2013/03/25
Optical camera is a high-precision optical instrument
and the optical lens must be always stable under various environments
so the structural materials of optical camera should have good stability and machining performance characteristics. Generally
the weight of the camera increases with the increasing size of optical camera aperture. The application of carbon fibre reinforced plastic(CFRP) in optical camera can help to improve the situation and meet the requirements of large volume and light weight. In this paper
the properties of several kind of materials used in camera structure were compared
the advantages of CFRP used in optical camera were analyzed
the CFRP application profiles of domestic and international were introduced
and the reason of gap was pointed out. There is a conclusion that CFRP will be widely used in the optical camera in China. 2012 IEEE.
Electronic system design of ultraviolet ozone vertical profile probe for aerography satellite (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Song K.
;
Wang S.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
The design of ultraviolet ozone vertical profile probe is illustrated and the electronic system is introduced in detail. The device is a compact
high precision
ultraviolet-vacuum
ultraviolet spectral radiometer
and is used to measure atmospheric solar backscattering spectral radiance and solar spectral irradiance. Noise of the system is analyzed and Numeric accumulation and synchronous demodulation was used to decrease the noise and the zero-drift of the instrument. The solar irradiance at altitude 830 km in 160-400 nm and the backscattering solar spectral radiance in the ultraviolet ozone absorption band at 12 wavelengths from 250 nm to 340 nm are obtained. Test results on orbit show that all the requested function is met successfully and the performance is stable. 2011 IEEE.
Design of co-path scanning long trace profiler for measurement of X-ray space optical elements (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Shun L.
;
Yan G.
;
Wei Z.
;
Yang Z.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
The Long Trace Profiler (LTP) is a precision surface slope error measurement instrument used in synchrotron radiation optics for many years. By making some modifications to the LTP system
we developed a co-path scanning LTP (CSLTP) system to test the cylindrical aspherical surface which used in X-ray space optics. To reduce the mistake caused by air turbulence and manufacture faults of optical elements used
the CSLTP is designed with the least difference between the testing beam path and the reference beam path. Also
it uses multiple-beam interference but double beam interference to reduce the width of beam fringe. This improves the position precision of the beam fringe on the image plane. 2010 SPIE.
Measuring instrument for radial composite deviations of high-precision master gear (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
作者:
Zhang Y.
;
Wang L.
;
Wang L.
;
Wang L.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
During double flank rolling composite detection
the radial composite deviations of master gears has been existed and transferred to the measured gear by the primary harmonic curve. In order to improve measurement accuracy
a measuring instrument is developed for radial composite deviations of high-precision master gear in the paper. This instrument uses the structure of spring-suspend swing span to overcome the shortcomings of large rotation errors
low sensitivity
low resolution and large measuring force appearing in the traditional combination-type gear inspection instrument. Artificial intelligence technology is used to improve the efficiency and accuracy of this instrument. The result is that the measuring apparatus is able to meet the requirement and improve efficiency through the measuring experiments on master gears of precision grade 2 with modulus 2 mm and 3 mm
respectively. 2010 SPIE.
Application of precision harmonic gear drive in focusing mechanism of space camera (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Smart Structures and Materials in Manufacturing and Testing, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
A kind of precision harmonic gear drive in the focusing mechanism of space camera is studied
which adopt external meshing complex wave transmission mode. Wave generator is combined with an elliptic cam and a flexible bearing around it. Flexspline is a structure of single wave with the same teeth. The output shaft is supported by a single cross-roller bearing. Ball screws connected the output shaft translate the rotational motion to the linear motion
and drive the focusing mirror repeated moving along the linear guide. The output rigid wheel is connected with absolute encoder to detect displacement of focusing movement. It has the characteristics of big transmission ratio
high precision
compact structure
high efficiency and smooth running etc. According to the practical application of this harmonic gear drive in the space camera
the location relationship between the displacement of focusing structure and the focal plane movement is derived
and the system error is analyzed
its accuracy is tested with the open-loop control method. Experimental results show that transmission ratio of the instrument is 1:70
repeated positional accuracy is 2m
which meet the requirements for use. 2010 SPIE.
Machining and testing technology research of industrial aspherical components (EI CONFERENCE)
会议论文
OAI收割
2009 IEEE International Conference on Mechatronics and Automation, ICMA 2009, August 9, 2009 - August 12, 2009, Changchun, China
作者:
Zhang X.
;
Yu H.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:19/0
  |  
提交时间:2013/03/25
Aspherical optical elements are widely used in modern optic system design. The tool model and workpiece deformation are established
and the tool radius error compensation is discussed . The aspherical optical elements are processed on a precision milling machine
and tested on a measuring instrument. 2009 IEEE.
The full hemisphere integrating measurement of the reflectance of black cavity (EI CONFERENCE)
会议论文
OAI收割
ICO20: Illumination, Radiation, and Color Technologies, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Wang Y.
;
Yu B.
;
Wang Y.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
The conical black cavities are used in the Solar Irradiance Absolute Radiometers (SIARs) of the solar constant monitor aboard on the SZ spaceship and of the Solar Total Irradiance Monitor (STIM) aboard on sun-synchronous polar orbit weather satellites. A low reflectance measurement instrument which is used for making the integrating measurement on the reflectance of the conical black cavity in a high precision within the full hemisphere (include the entrance of the Ulbrichtsphere) has been constructed. The characteristic of the instrument is the employment of a semi-transparent mirror
which is mounted in an inclination angle of 45 degrees in front of the entrance of the Ulbrichtsphere. The incident beam is reflected to the black cavity or white board by the semi-transparent mirror. A portion of those
which is made diffused reflection through the black cavity or white board
is measured by the detector located in the side face of the Ulbrichtsphere
and the other portion which is reflected to the entrance is measured by the other detector
after passing through the semi-transparent mirror
and then being focused on by an ellipsoidal mirror. The two measurement data are added up to get the integrating reflectance within full hemisphere. The presentation and verification on the measurement result of the reflectance of the black cavity and its precision are described in this article. The absolute accuracy can reach 0.012%.
A new high-precision measurement system used in the image calibration of large-sized photographic instrument (EI CONFERENCE)
会议论文
OAI收割
Optical Design and Testing II, November 8, 2004 - November 11, 2004, Beijing, United states
作者:
Li Y.
;
Liu Z.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
The purpose of characterizing the image of large-sized photographic instrument is to make the directionality of three coordinate axises in the three-dimensional coordinate of the image and the directionality of three axises of coordinate in the frame of axes of the instrument keep the same direction. This problem was solved by a high-precision measurement system composed of double-theodolite and a set of communication system. Two cube prisms will be respectively placed on the image surface and the instrument. Every cube prism will stand for a three-dimensional coordinate from the image surface or the instrument. As a result
the interdependence of both coordinates from the image surface and the instrument can be obtained by measuring the interdependence of the both cube prisms with autocollimation survey axiom. In the survey system
two high-precision stations TDA5005 from Leica Company will be selected as double-theodolite and the interdependence of both coordinates can be achieved by moving the station only at one time. Therefore
this measurement system is a high efficient and high-precision surveying method to the image calibration of the large-sized photographic instrument. Based on the experiment
its measuring accuracy can reach arc-second level.