中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
_filter
_filter
_filter
筛选

浏览/检索结果: 共3条,第1-3条 帮助

条数/页: 排序方式:
Analysis of Harmonically Forced Duffing Oscillator with Time Delay State Feedback by Incremental Harmonic Balance Method 期刊论文  OAI收割
JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2021, 页码: 13
作者:  
Wu H(吴晗);  Ceng XH(曾晓辉);  Liu YB(刘玉标);  Lai J(赖姜);  Lai J(赖姜)
  |  收藏  |  浏览/下载:27/0  |  提交时间:2021/05/06
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Song K.-F.;  Li J.-L.;  Zhang W.-L.;  Wang Y.-L.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.  
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Wang L.-J.;  Zhang J.-P.;  Wang L.-J.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1  Second  Others  zoom ratio =1:4  binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate  in order to balance 5th spherical aberration  and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First  5th coma aberration and 5th astigmatic aberration  the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner  high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited  both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm  MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm  MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046  the coma aberration 0.055 and astigmatic aberration 0.034.