中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共7条,第1-7条 帮助

条数/页: 排序方式:
Influence of the Choice of Reference Planes on the Determination of 2D and 3D Joint Roughness Parameters 期刊论文  OAI收割
ROCK MECHANICS AND ROCK ENGINEERING, 2021, 页码: 14
作者:  
Wong, Louis Ngai Yuen;  Meng, Fanzhen;  Zhou, Hui;  Yu, Jin;  Cheng, Guangtan
  |  收藏  |  浏览/下载:32/0  |  提交时间:2021/06/18
Improved method of target detection on optoelectronic hybrid joint transform correlator in cluttered scences (EI CONFERENCE) 会议论文  OAI收割
2011 3rd International Conference on Mechanical and Electronics Engineering, ICMEE 2011, September 23, 2011 - September 25, 2011, Hefei, China
作者:  
Yang L.;  Yang L.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
A classical joint transform correlator (JTC) usually yields large correlation sidelobes as well as a large correlation peak width  strong zero-order peak  and low diffraction efficiency  which make the detection ability of JTC lower. To overcome these difficulties  firstly  a joint power spectrum (JPS) subtraction technique in Fourier plane was proposed  where reference image power spectrum and object image power spectrum are subtracted from the JPS before inverse Fourier-transform operation  it is obvious that the modified JPS removes the zero-order term. Secondly  a fringe-adjusted filter (FAF) was presented to suppress sidelobes and noises. The modified JPS is multiplied by a FAF before the inverse Fourier-transform operation to obtain the cross-correlation peak. Computer simulations demonstrated the improved method can obviously remove zero-order diffraction and effectively suppress the sidelobes and noises compared with classic JTC  and then improve the detection ability for JTC. Experimental results presented the sharp correlation peak and also confirmed the method effectiveness. (2012) Trans Tech Publications  Switzerland.  
Method of improving the accuracy of image motion measurement for panoramic aerial cameras (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Jia P.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
To improve the accuracy of image motion measurement for panoramic aerial cameras  the paper proposed a method of real-time image motion measurement based on 2D spatial correlation. An auxiliary area CCD is positioned paralleled to the main linear TDI CCD in the focal plane of the camera. For every frame of the image sequence taken by the auxiliary CCD  a prediction on the displacement of the current image in the flight direction is made based on the forward image motion velocity. The current and the reference images are combined together for 2D-correlation  which products an image motion vector. By decomposing the vector  both the forward and pendulum-swing image motions can be determined. The demanding computational requirements for the real-time 2D-correlation are covered by a joint transform optical correlator. Simulation test results show that the accuracy is improved and the measurement error is within 0.2 pixels for input images with SNR=1 dB. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Design of co-path scanning long trace profiler for measurement of X-ray space optical elements (EI CONFERENCE) 会议论文  OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Shun L.; Yan G.; Wei Z.; Yang Z.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
Thermal difference analysis and athermalization design of infrared optical system (EI CONFERENCE) 会议论文  OAI收割
Optical Design and Testing IV, October 18, 2010 - October 20, 2010, Beijing, China
作者:  
Zhang X.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
When infrared optical system works in a large temperature range  the thermal effect of optical lens and optical tube will produce image plane shift and lead to imaging quality deterioration. In order to eliminate the thermal aberration  the athermalization design principles of infrared optical system were introduced  and some commonly used methods of thermal difference compensation were described. Proceeding from single lens  the thermal difference caused by temperature changing was analyzed  and the relationship between temperature and focus shift was obtained. Considering optical tube thermal expansion  a set of equations to estimate the thermal difference of lens group was given. Finally  an infrared optical imaging system that can work under the temperature range of -40C to 60C was design according to athermal technique  in which a new mechanical passive temperature compensation was proposed. Through simulation  the athermalization design could make imaging plane shift the smallest. The simulation results coincided with the theoretical formula  and the design had reference value in engineering. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Study of high precision non-contact measurement based on CCD (EI CONFERENCE) 会议论文  OAI收割
4th International Conference on Information Technology and Applications, ICITA 2007, January 15, 2007 - January 18, 2007, Harbin, China
Lin L.; Yun F.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
In this paper a method that measures relatively positionrelationshipquickly and accurately between two vehicles both on a horizontal plane is introduced. When the linear CCD camera placed on the end of manipulator scans two point targets located on the other vehicle  by virtue of the spatial intersection principle and trigonometry theorem  the relative position relationship between the loading vehicles and launching ones can be gotten(i.e. the spatial coordinate parameters of x  y  z and the angle displacement ). At the same time the paper establishes that the measurement error of length is less than 1mm  by analysis of thee rror analysis and the simulation of computer. The angle displacement is less than 3  which satisfies the technical requests. So the vehicle orientation and loading missiles can be both done at the shortest time. It meets the demand of centralization between the measurement and execution. Forboth automatic transshipment and spatial position relationship measurement  the study is valuable. And the manipulator is measure device as well as executive one so that residual inherent error decreases according to identical reference principle. Therefore the measure precision can be improved greatly.  
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.; Li H.; Chen C.; Zhou C.; Qian S.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal  spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle  optical system  mechanical constructions  DC serve motor control system  array detector  data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy  low cost  multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.