中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共12条,第1-10条 帮助

条数/页: 排序方式:
Boundary value problems of fractional Fokker-Planck equations 期刊论文  OAI收割
COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2017, 卷号: 73, 期号: 6, 页码: 959-969
作者:  
Aleroev, Temirkhan S.;  Aleroeva, Hedi T.;  Huang, Jianfei;  Tamm, Mikhail V.;  Tang, Yifa
  |  收藏  |  浏览/下载:28/0  |  提交时间:2018/07/30
Improved method of target detection on optoelectronic hybrid joint transform correlator in cluttered scences (EI CONFERENCE) 会议论文  OAI收割
2011 3rd International Conference on Mechanical and Electronics Engineering, ICMEE 2011, September 23, 2011 - September 25, 2011, Hefei, China
作者:  
Yang L.;  Yang L.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
A classical joint transform correlator (JTC) usually yields large correlation sidelobes as well as a large correlation peak width  strong zero-order peak  and low diffraction efficiency  which make the detection ability of JTC lower. To overcome these difficulties  firstly  a joint power spectrum (JPS) subtraction technique in Fourier plane was proposed  where reference image power spectrum and object image power spectrum are subtracted from the JPS before inverse Fourier-transform operation  it is obvious that the modified JPS removes the zero-order term. Secondly  a fringe-adjusted filter (FAF) was presented to suppress sidelobes and noises. The modified JPS is multiplied by a FAF before the inverse Fourier-transform operation to obtain the cross-correlation peak. Computer simulations demonstrated the improved method can obviously remove zero-order diffraction and effectively suppress the sidelobes and noises compared with classic JTC  and then improve the detection ability for JTC. Experimental results presented the sharp correlation peak and also confirmed the method effectiveness. (2012) Trans Tech Publications  Switzerland.  
Correction of baseline drifts due to the pressure changes between attenuated total reflection prism and human skin for noninvasive blood glucose sensing with Fourier Transform infrared spectroscopy (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
作者:  
Wang D.
收藏  |  浏览/下载:48/0  |  提交时间:2013/03/25
Space camera dynamic image quality measurement and evaluation (EI CONFERENCE) 会议论文  OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:21/0  |  提交时间:2013/03/25
Design and demonstration of micro multi-step mirrors and light source in micro FTIR (EI CONFERENCE) 会议论文  OAI收割
6th IEEE International Conference on Nano/Micro Engineered and Molecular Systems, NEMS 2011, February 20, 2011 - February 23, 2011, Kaohsiung, Taiwan
Liang Z.; Fu J.; Feng C.; Liang J.
收藏  |  浏览/下载:43/0  |  提交时间:2013/03/25
To obtain high resolution  high signal-to-noise ratio (SNR)  high reliability and real time in wide spectral range  we study the space modulation Micro Fourier Transform Spectrometer (FTS) based on multi-step mirrors covering the spectral range of 3-5m and 8-12 m in theory and experiment. The influences of spectrum reconstruction caused by the diffraction and extended light source in Fourier Transform Infrared Spectrometer (FTIR) are analyzed. A method to reduce the noises in spectrum reconstruction and the relationship between coherent intensity and solid angle of light source are discussed. An extended light source with suitable size is chosen  considering the requirement of SNR and spectrum resolving power in the optical design. Furthermore  the fabrication of micro multi-step mirrors  which is the core part of FTS  is investigated. Three methods for fabricating multi-step micro mirrors are demonstrated. 2011 IEEE.  
The movement estimation of target and background by fourier phase spectrum difference (EI CONFERENCE) 会议论文  OAI收割
2010 6th International Conference on Wireless Communications, Networking and Mobile Computing, WiCOM 2010, September 23, 2010 - September 25, 2010, Chengdu, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.;  Wang J.;  Zhang S.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Chirp estimation of PZT for integrating-bucket method (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang J.;  Liu W.;  Zhang J.;  Zhang J.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
The nonlinear response of the PZT for the integrating bucket method is studied by our proposed method: discrete chirp Fourier transform (DCFT) and maximum likelihood estimation (MLE) techniques for the integrating bucket method. Based on the signal processing theory  the intensity obtained from CCD is processed by the DCFT and thus nonlinear response and chirp coefficient of the PZT can be coarsely estimated. This is followed by the MLE method  in which an iterative optimization process is complemented for accurately estimating the nonlinear response and chirp coefficient of the PZT. One key advantage of the proposed method is that not only the nonlinear response and chirp coefficient of the PZT can be acquired  but also initial phase acquired. Our method is tested by simulating conditions under which a certain magnitude of nonlinearity is assumed. Nonlinear response attained by the DCFT is compared to that attained by the MLE  and a difference between the actual nonlinear response of the PZT and our accurate estimation by the proposed method is revealed. Several factors that will have influence on the nonlinear response of the PZT are discussed. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Micro assembled fourier transform spectrometer (EI CONFERENCE) 会议论文  OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 19, 2008 - November 21, 2008, Chengdu, China
作者:  
Liang J.-Q.;  Zhang J.;  Zhang J.;  Zhang J.;  Wang B.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
With the trend of minimization of Fourier transform spectrometer (FTS) which is particularly pronounced in many applications  a model of a micro FTS with no moving parts is proposed and analyzed. During analyzng  the gradients which mainly introduce phase error are accounted. Based on these assumptions and the improved Mertz phase correcting method  the spectrum of signal is simulated with real extended light source. The resolution can be up to 3.43nm@800nm  with high signal-to-noise ratio (SNR) limiting resolving ability 6.8dB. In addition  the fabrication method of components are illuminated and demonstrated  which can not only make it bear some advantages over conventional micro dispersive spectrometers  but also afford some new concepts on the design of spectrometers with improved performance. 2009 SPIE.  
Correction method for detection of the frequencies of railway fsk signals (EI CONFERENCE) 会议论文  OAI收割
2008 9th International Conference on Signal Processing, ICSP 2008, October 26, 2008 - October 29, 2008, Beijing, China
作者:  
Yu J.
收藏  |  浏览/下载:63/0  |  提交时间:2013/03/25
In order to acquire the information of railway binary frequency-shift keying signals  which include upper/down side frequencies and base low-frequency with high-accuracy  a novel frequency detection algorithm for France UM-71 system is proposed. Combining fast Fourier transform with the ratio correction method  the carrier frequency and the base frequency are obtained. Furthermore  the hardware consumption has been decreased. And it possesses the advantage of simple algorithm and fast operation speed. Comparing with the detection of the base frequency  the upper/down side frequency of railway signal is more difficult. Based on spectrum analysis and the spectrum correction  a new method  which adopts the sliding window  is put forward in this paper. The absolute differences between the upper side frequencies and the down side frequencies obtained are regarded as the criterion for judgment. Then the set of data  in which the maximum absolute value is  is to be the result of the upper/down side frequency. Because the sliding window will go through every stage when the upper/down side frequency changes  therefore  it is not sensitive enough to the position of data which need to be transformed. Using the method mentioned above  the experiment results show that the accuracy requirement of the side frequency is satisfied well. 2008 IEEE.  
The cell thickness and twist angle measurement of twist nematic liquid crystal cell by rotation of a quarter-wave plate using fourier analysis method (EI CONFERENCE) 会议论文  OAI收割
Asia Display 2007, AD'07, March 12, 2007 - March 16, 2007, Shanghai, China
Cui H.-Q.; Ling Z.-H.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25