中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
计算机网络信息中心 [1]
采集方式
OAI收割 [2]
iSwitch采集 [1]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2009 [2]
2005 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Automated grain boundary detection using the level set method
期刊论文
iSwitch采集
Computers & geosciences, 2009, 卷号: 35, 期号: 2, 页码: 267-275
作者:
Lu, Bibo
;
Cui, Min
;
Liu, Qiang
;
Wang, Yangang
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2019/05/09
Grain boundary detection
The level set method
Automated image segmentation
Strain analysis
The deviation of color matching algorithm in the field of full-color LED display (EI CONFERENCE)
会议论文
OAI收割
2009 2nd International Congress on Image and Signal Processing, CISP'09, October 17, 2009 - October 19, 2009, Tianjin, China
作者:
Wang Y.
;
Chen Y.
;
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
In this paper
a color gamut transformation method which transformed the different color gamut into a same one has been proposed. In the transforming process
the deviation which was arose from the quantization error and the truncation error were existing. If the deviation was out of the color tolerance
the uniformity of the screen color will be deteriorated. Firstly
the color tolerance of vision was calculated by the color-difference formula. Secondly
in the full-color LED display experiments
it was analyzed that the tri -color tolerance values are respectively 2.5
2.8 and 1.3. According to the tri -color tolerance values and the color difference formula
the express of the quantization precision
gray value and the color difference was set up. Finally the gray-scale range of the color uniformity was analyzed by the collected data
it was concluded that the uniformity of the display was satisfied the requirement of the visual when the range of the gray level was [11
14]
and when the range was [1
11]
the value of the color difference was also reduced significantly. 2009 IEEE.
A new high-precision measurement system used in the image calibration of large-sized photographic instrument (EI CONFERENCE)
会议论文
OAI收割
Optical Design and Testing II, November 8, 2004 - November 11, 2004, Beijing, United states
作者:
Li Y.
;
Liu Z.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
The purpose of characterizing the image of large-sized photographic instrument is to make the directionality of three coordinate axises in the three-dimensional coordinate of the image and the directionality of three axises of coordinate in the frame of axes of the instrument keep the same direction. This problem was solved by a high-precision measurement system composed of double-theodolite and a set of communication system. Two cube prisms will be respectively placed on the image surface and the instrument. Every cube prism will stand for a three-dimensional coordinate from the image surface or the instrument. As a result
the interdependence of both coordinates from the image surface and the instrument can be obtained by measuring the interdependence of the both cube prisms with autocollimation survey axiom. In the survey system
two high-precision stations TDA5005 from Leica Company will be selected as double-theodolite and the interdependence of both coordinates can be achieved by moving the station only at one time. Therefore
this measurement system is a high efficient and high-precision surveying method to the image calibration of the large-sized photographic instrument. Based on the experiment
its measuring accuracy can reach arc-second level.