中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共3条,第1-3条 帮助

条数/页: 排序方式:
The impact of hydrostatic pressure and uniaxial strain on the of Ni-Co-Mn-Sb Heusler alloy involving 4 O martensite 期刊论文  OAI收割
MATERIALS TODAY COMMUNICATIONS, 2023, 卷号: 34, 页码: 11
作者:  
Xia, Qinhan;  Tan, Changlong;  Ma, Tianyou;  Liu, Rui;  Tian, Xiaohua
  |  收藏  |  浏览/下载:16/0  |  提交时间:2024/01/07
Comparison of radiation temperature measurement precision between middlewave and longwave thermal-imaging systems (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
作者:  
Sun Z.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
A comparison study on temperature measurement precision between middlewave 3-5m and longwave 8-12m measuring thermal imaging systems has been conducted. The study was limited to systems working in indoor conditions and the target's temperature is in the range of 270K900K. First  the Disturb Resisting Function (DRF) of infrared systems is deduced. On the base of DRF curve  we find that the middlewave infrared system get the smaller influences under the same size disturb compared with the longwave system. A theory of the influence of target's physical characteristic and measurement conditions on the accuracy of temperature measurements has been developed. On the basis of the developed formulas an analysis of the influence of signal disturbances (because of incorrectly assumed emissivity  limited transmittance of the atmosphere  radiation reflected by the object and shift of optics radiation) on the accuracy of temperature measurement has been made. It has been found that the middlewave systems in typical temperature range offer generally better accuracy in temperature measurement than the longwave ones do. 2012 IEEE.  
The lightweight design of the inner framework of the opto-electronic stabilization platform based on finite element analysis (EI CONFERENCE) 会议论文  OAI收割
2011 IEEE 18th International Conference on Industrial Engineering and Engineering Management, IE and EM 2011, September 3, 2011 - September 5, 2011, Changchun, China
Zou Q.; Ma H.-L.; Hu Y.; Ding J.-W.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
The airborne opto-electronic stabilization platform should have the characteristics of high requirements for stability  tracking accuracy and lightweight. In order to verify the rationality of the main load-bearing structure  the inner-gimbal  finite element analysis was performed. Because of the poor working conditions of the airborne opto-electronic stabilization platform and the wide range of working temperature variation  -45 C 60 C  according to the actual working environment  air-resistance and temperature were added to the loads of the inner-gimbal in analysis. What's more  based on the analysis results  lightweight design was performed to the initial model and 64.37% of mass was decreased. The remarkable effect was obtained. This research is going to be instructive to design and production of the airborne opto-electronic stabilization platform in the future. 2011 IEEE.