A Dual-FSM GI LiDAR Imaging Control Method Based on Two-Dimensional Flexible Turntable Composite Axis Tracking 期刊论文  OAI收割
Remote Sensing, 2024, 卷号: 16, 期号: 10
作者:  
Cao, Yu;  Xie, Meilin;  Wang, Haitao;  Hao, Wei;  Guo, Min
  |  收藏  |  浏览/下载:24/0  |  提交时间:2024/09/13
A Tracking Imaging Control Method for Dual-FSM 3D GISC LiDAR 期刊论文  OAI收割
Remote Sensing, 2022, 卷号: 14, 期号: 13
作者:  
Cao, Yu;  Su, Xiuqin;  Qian, Xueming;  Wang, Haitao;  Hao, Wei
  |  收藏  |  浏览/下载:63/0  |  提交时间:2022/08/25
Research on two-dimensional turntable tracking and aiming system based on BLDC speed regulation system 会议论文  OAI收割
Chongqing, China, 2019-05-24
作者:  
Cao, Yu;  Wang, Haitao;  Jing, Feng;  Han, Junfeng;  Xie, Meilin
  |  收藏  |  浏览/下载:39/0  |  提交时间:2019/09/20
The application of adaptive enhancement algorithm based on gray entropy in mammary gland CR image (EI CONFERENCE) 会议论文  OAI收割
2012 2nd International Conference on Consumer Electronics, Communications and Networks, CECNet 2012, April 21, 2012 - April 23, 2012, Three Gorges, China
Zhang M.-H.; Zhang Y.-Y.
收藏  |  浏览/下载:39/0  |  提交时间:2013/03/25
Mammary gland is composed entirely of soft tissue with approximate density  therefore mammary gland CR medicine radiation image presents a low contrast  and slight difference changes may be a manifestation of tumor  so it is necessary to enhance mammary gland CR image to improve its visual quality in order to meet the demands of doctor's clinical diagnosis. However the general enhancement algorithms over enhance the contrast and noise  due to image details lost  aiming at the defects  a mammary gland CR medicine image adaptive enhancement arithmetic based on image gray entropy is put forward. The arithmetic adapts dizzy image to magnify selected spatial frequency response in order to enhance the edge details of mammary gland CR images. It can adjust weighted factor K according to image gray characteristics namely pixel gray entropy. Experiments results demonstrate that mammary gland CR image enhanced by the algorithm has abundant details and high signal-to-noise ratio  moreover  CR image enhanced has good visual effect. So the method is effective and fit for enhancing CR medical radiation image edge details. 2012 IEEE.  
The research of digltal CR medicine image adapitive enhancement method (EI CONFERENCE) 会议论文  OAI收割
4th International Conference on Mechanical and Electrical Technology, ICMET 2012, July 24, 2012 - July 26, 2012, Kuala Lumpur, Malaysia
Ming-Hui Z.; Yao-Yu Z.
收藏  |  浏览/下载:71/0  |  提交时间:2013/03/25
Digital CR medicine radiation image is in doctor's favor and has became medicine imaging technology new hot spot because of its high gray contrast  powerful computer disposal function  little radiation dosage  non-film diagnosis  different area consultation. But degradation of digital X-ray medical image such as low contrast and blurring during radiographic imaging  caused by complexity of body tissue and effects of X-ray scattering and electrical noise etc.  can worsen the results of analysis and diagnosis. So it is usually needed that CR medicine image is enhanced to improve its vision quality  and easy to doctor's more accurate diagnosis. The general enhancement algorithms over enhancing the contrast and lose image details  aiming at the defects  an enhancement algorithm for CR image is proposed based on the ratio of deviation to mean of domain. The arithmetic enhance CR image edge details by adjusting factor K based on the ratio of deviation to mean of domain of CR image. Experiment results demonstrate that the algorithm enhances CR image detail and CR image enhanced has good visual effect  the adaptive enhancement method is fit for CR medicine image. (2012) Trans Tech Publications  Switzerland.  
Transferring error analysis of reflex light-tube in azimuth aiming system (EI CONFERENCE) 会议论文  OAI收割
2012 5th International Symposium on Computational Intelligence and Design, ISCID 2012, October 28, 2012 - October 29, 2012, Hangzhou, China
作者:  
Zhao Y.;  Zhao Y.;  Zhao Y.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
A brightness and color correction method of LED display based on CCD camera (EI CONFERENCE) 会议论文  OAI收割
2012 International Applied Mechanics, MechatronicsAutomation and System Simulation Meeting, AMMASS 2012, June 24, 2012 - June 26, 2012, Hangzhou, China
作者:  
Wang R.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
The correction methods of LED displays are aiming to address the uniform issues which includes brightness aspect and color aspect. The correction method use a 33 correction coefficients matrix to reshape the pulse width of each LED. To calculate the correction coefficients  a linear system is established  which includes a color CCD and a LED display. And a correction algorithm is introduced based on the color CCD. This algorithm describes the relationships of the main color components of a LED  when the gray level of a LED is increasing or decreasing  the three main color components would change according to the correction coefficients. The results shows that the correction based on this algorithm improved the performance of LED displays. (2012) Trans Tech Publications  Switzerland.  
The sequence measurement system of the IR camera (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:  
Zhang H.-B.;  Han H.-X.;  Geng A.-H.
收藏  |  浏览/下载:41/0  |  提交时间:2013/03/25
Currently  the IR cameras are broadly used in the optic-electronic tracking  optic-electronic measuring  fire control and optic-electronic countermeasure field  but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras  the sequence measurement system of the IR camera is designed  and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system  and the precise sequence of the IR camera's output signal has been achieved  the detailed document of the IR camera has been supplied to the continuous image transmission system  image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part  LVDS input interface part  FPGA part  CameraLink output interface part and etc  thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system  and because the image processing card and image memory card always use the CameraLink interface as its input interface style  the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system  the sequence measurement program  the pixel clock modification  the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame  pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal  the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera  supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval  lval  pixclk  line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably  laying foundation for the continuous system. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
The new approach for infrared target tracking based on the particle filter algorithm (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:  
Sun H.;  Han H.-X.;  Sun H.
收藏  |  浏览/下载:63/0  |  提交时间:2013/03/25
Target tracking on the complex background in the infrared image sequence is hot research field. It provides the important basis in some fields such as video monitoring  precision  and video compression human-computer interaction. As a typical algorithms in the target tracking framework based on filtering and data connection  the particle filter with non-parameter estimation characteristic have ability to deal with nonlinear and non-Gaussian problems so it were widely used. There are various forms of density in the particle filter algorithm to make it valid when target occlusion occurred or recover tracking back from failure in track procedure  but in order to capture the change of the state space  it need a certain amount of particles to ensure samples is enough  and this number will increase in accompany with dimension and increase exponentially  this led to the increased amount of calculation is presented. In this paper particle filter algorithm and the Mean shift will be combined. Aiming at deficiencies of the classic mean shift Tracking algorithm easily trapped into local minima and Unable to get global optimal under the complex background. From these two perspectives that "adaptive multiple information fusion" and "with particle filter framework combining"  we expand the classic Mean Shift tracking framework.Based on the previous perspective  we proposed an improved Mean Shift infrared target tracking algorithm based on multiple information fusion. In the analysis of the infrared characteristics of target basis  Algorithm firstly extracted target gray and edge character and Proposed to guide the above two characteristics by the moving of the target information thus we can get new sports guide grayscale characteristics and motion guide border feature. Then proposes a new adaptive fusion mechanism  used these two new information adaptive to integrate into the Mean Shift tracking framework. Finally we designed a kind of automatic target model updating strategy to further improve tracking performance. Experimental results show that this algorithm can compensate shortcoming of the particle filter has too much computation  and can effectively overcome the fault that mean shift is easy to fall into local extreme value instead of global maximum value.Last because of the gray and fusion target motion information  this approach also inhibit interference from the background  ultimately improve the stability and the real-time of the target track. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
DOA estimation algorithm of UWB signal based on unitary circuit array (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
作者:  
Zhang X.;  Chen X.;  Chen X.;  Chen X.;  Zhang X.