中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与... [16]
西安光学精密机械研究... [3]
半导体研究所 [1]
采集方式
OAI收割 [20]
内容类型
会议论文 [17]
期刊论文 [3]
发表日期
2024 [1]
2022 [1]
2019 [1]
2012 [4]
2011 [2]
2010 [3]
更多
学科主题
光电子学 [1]
筛选
浏览/检索结果:
共20条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
A Dual-FSM GI LiDAR Imaging Control Method Based on Two-Dimensional Flexible Turntable Composite Axis Tracking
期刊论文
OAI收割
Remote Sensing, 2024, 卷号: 16, 期号: 10
作者:
Cao, Yu
;
Xie, Meilin
;
Wang, Haitao
;
Hao, Wei
;
Guo, Min
  |  
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2024/09/13
GI LiDAR
flexible load
active disturbance rejection control
dual-FSM tracking and aiming
remote-sensing imaging
A Tracking Imaging Control Method for Dual-FSM 3D GISC LiDAR
期刊论文
OAI收割
Remote Sensing, 2022, 卷号: 14, 期号: 13
作者:
Cao, Yu
;
Su, Xiuqin
;
Qian, Xueming
;
Wang, Haitao
;
Hao, Wei
  |  
收藏
  |  
浏览/下载:63/0
  |  
提交时间:2022/08/25
3D GISC LiDAR
dual-FSM tracking and aiming
FSM feedback decoupling
composite axis control
remote-sensing imaging
Research on two-dimensional turntable tracking and aiming system based on BLDC speed regulation system
会议论文
OAI收割
Chongqing, China, 2019-05-24
作者:
Cao, Yu
;
Wang, Haitao
;
Jing, Feng
;
Han, Junfeng
;
Xie, Meilin
  |  
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2019/09/20
BLDC
Torque ripple suppression
High Precision Tracking and Aiming
The application of adaptive enhancement algorithm based on gray entropy in mammary gland CR image (EI CONFERENCE)
会议论文
OAI收割
2012 2nd International Conference on Consumer Electronics, Communications and Networks, CECNet 2012, April 21, 2012 - April 23, 2012, Three Gorges, China
Zhang M.-H.
;
Zhang Y.-Y.
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2013/03/25
Mammary gland is composed entirely of soft tissue with approximate density
therefore mammary gland CR medicine radiation image presents a low contrast
and slight difference changes may be a manifestation of tumor
so it is necessary to enhance mammary gland CR image to improve its visual quality in order to meet the demands of doctor's clinical diagnosis. However the general enhancement algorithms over enhance the contrast and noise
due to image details lost
aiming at the defects
a mammary gland CR medicine image adaptive enhancement arithmetic based on image gray entropy is put forward. The arithmetic adapts dizzy image to magnify selected spatial frequency response in order to enhance the edge details of mammary gland CR images. It can adjust weighted factor K according to image gray characteristics namely pixel gray entropy. Experiments results demonstrate that mammary gland CR image enhanced by the algorithm has abundant details and high signal-to-noise ratio
moreover
CR image enhanced has good visual effect. So the method is effective and fit for enhancing CR medical radiation image edge details. 2012 IEEE.
The research of digltal CR medicine image adapitive enhancement method (EI CONFERENCE)
会议论文
OAI收割
4th International Conference on Mechanical and Electrical Technology, ICMET 2012, July 24, 2012 - July 26, 2012, Kuala Lumpur, Malaysia
Ming-Hui Z.
;
Yao-Yu Z.
收藏
  |  
浏览/下载:71/0
  |  
提交时间:2013/03/25
Digital CR medicine radiation image is in doctor's favor and has became medicine imaging technology new hot spot because of its high gray contrast
powerful computer disposal function
little radiation dosage
non-film diagnosis
different area consultation. But degradation of digital X-ray medical image such as low contrast and blurring during radiographic imaging
caused by complexity of body tissue and effects of X-ray scattering and electrical noise etc.
can worsen the results of analysis and diagnosis. So it is usually needed that CR medicine image is enhanced to improve its vision quality
and easy to doctor's more accurate diagnosis. The general enhancement algorithms over enhancing the contrast and lose image details
aiming at the defects
an enhancement algorithm for CR image is proposed based on the ratio of deviation to mean of domain. The arithmetic enhance CR image edge details by adjusting factor K based on the ratio of deviation to mean of domain of CR image. Experiment results demonstrate that the algorithm enhances CR image detail and CR image enhanced has good visual effect
the adaptive enhancement method is fit for CR medicine image. (2012) Trans Tech Publications
Switzerland.
Transferring error analysis of reflex light-tube in azimuth aiming system (EI CONFERENCE)
会议论文
OAI收割
2012 5th International Symposium on Computational Intelligence and Design, ISCID 2012, October 28, 2012 - October 29, 2012, Hangzhou, China
作者:
Zhao Y.
;
Zhao Y.
;
Zhao Y.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
According to the analysis of structural type and light transfer characteristics of azimuth aiming systems
the calculation formula for the transferring error based on the adjustment and installation error was established
and theoretical simulation was carried out
which provided a theoretical basis for the application of reflex light-tube in azimuth aiming systems. 2012 IEEE.
A brightness and color correction method of LED display based on CCD camera (EI CONFERENCE)
会议论文
OAI收割
2012 International Applied Mechanics, MechatronicsAutomation and System Simulation Meeting, AMMASS 2012, June 24, 2012 - June 26, 2012, Hangzhou, China
作者:
Wang R.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
The correction methods of LED displays are aiming to address the uniform issues which includes brightness aspect and color aspect. The correction method use a 33 correction coefficients matrix to reshape the pulse width of each LED. To calculate the correction coefficients
a linear system is established
which includes a color CCD and a LED display. And a correction algorithm is introduced based on the color CCD. This algorithm describes the relationships of the main color components of a LED
when the gray level of a LED is increasing or decreasing
the three main color components would change according to the correction coefficients. The results shows that the correction based on this algorithm improved the performance of LED displays. (2012) Trans Tech Publications
Switzerland.
The sequence measurement system of the IR camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang H.-B.
;
Han H.-X.
;
Geng A.-H.
收藏
  |  
浏览/下载:41/0
  |  
提交时间:2013/03/25
Currently
the IR cameras are broadly used in the optic-electronic tracking
optic-electronic measuring
fire control and optic-electronic countermeasure field
but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras
the sequence measurement system of the IR camera is designed
and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system
and the precise sequence of the IR camera's output signal has been achieved
the detailed document of the IR camera has been supplied to the continuous image transmission system
image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part
LVDS input interface part
FPGA part
CameraLink output interface part and etc
thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system
and because the image processing card and image memory card always use the CameraLink interface as its input interface style
the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system
the sequence measurement program
the pixel clock modification
the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame
pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal
the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera
supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval
lval
pixclk
line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably
laying foundation for the continuous system. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
The new approach for infrared target tracking based on the particle filter algorithm (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Sun H.
;
Han H.-X.
;
Sun H.
收藏
  |  
浏览/下载:63/0
  |  
提交时间:2013/03/25
Target tracking on the complex background in the infrared image sequence is hot research field. It provides the important basis in some fields such as video monitoring
precision
and video compression human-computer interaction. As a typical algorithms in the target tracking framework based on filtering and data connection
the particle filter with non-parameter estimation characteristic have ability to deal with nonlinear and non-Gaussian problems so it were widely used. There are various forms of density in the particle filter algorithm to make it valid when target occlusion occurred or recover tracking back from failure in track procedure
but in order to capture the change of the state space
it need a certain amount of particles to ensure samples is enough
and this number will increase in accompany with dimension and increase exponentially
this led to the increased amount of calculation is presented. In this paper particle filter algorithm and the Mean shift will be combined. Aiming at deficiencies of the classic mean shift Tracking algorithm easily trapped into local minima and Unable to get global optimal under the complex background. From these two perspectives that "adaptive multiple information fusion" and "with particle filter framework combining"
we expand the classic Mean Shift tracking framework.Based on the previous perspective
we proposed an improved Mean Shift infrared target tracking algorithm based on multiple information fusion. In the analysis of the infrared characteristics of target basis
Algorithm firstly extracted target gray and edge character and Proposed to guide the above two characteristics by the moving of the target information thus we can get new sports guide grayscale characteristics and motion guide border feature. Then proposes a new adaptive fusion mechanism
used these two new information adaptive to integrate into the Mean Shift tracking framework. Finally we designed a kind of automatic target model updating strategy to further improve tracking performance. Experimental results show that this algorithm can compensate shortcoming of the particle filter has too much computation
and can effectively overcome the fault that mean shift is easy to fall into local extreme value instead of global maximum value.Last because of the gray and fusion target motion information
this approach also inhibit interference from the background
ultimately improve the stability and the real-time of the target track. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
DOA estimation algorithm of UWB signal based on unitary circuit array (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
作者:
Zhang X.
;
Chen X.
;
Chen X.
;
Chen X.
;
Zhang X.
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2013/03/25
In this contribution
unitary circular array (UCA) techniques for estimating Direction of Arrival (DOA) of Ultra wideband (UWB) propagation signals are studied. Aiming at the defects of the DOA algorithms under uniform linear array (ULA) only can estimate 180 degree unfaintness angles
in this paper
the algorithms of one-dimensional and two-dimensional DOA estimation for UWB signals based on unitary circular array (UCA) are proposed. In order to estimate DS-UWB signals within 360 degree angles
the UCA-CSM-RB-MUSIC algorithm is proposed
which can estimate 360 degree unfaintness azimuth angles. 2010 IEEE.