中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共8条,第1-8条 帮助

条数/页: 排序方式:
Research on Quantum Efficiency Calibration of SVOM VT CCDs 会议论文  OAI收割
Beijing, China, 2023-07-25
作者:  
Yue, Pan;  Lijuna, Dan;  Zhonghana, Sun;  Chaoa, Huang;  Weia, Li
  |  收藏  |  浏览/下载:9/0  |  提交时间:2024/02/07
In-vehicle localization based on multi-channel Bluetooth Low Energy received signal strength indicator 期刊论文  OAI收割
INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2020, 卷号: 16, 期号: 1, 页码: 13
作者:  
Gao Yuan;  Zhao Ze;  Huang Changcheng;  Han Chuanqi;  Cui Li
  |  收藏  |  浏览/下载:43/0  |  提交时间:2020/12/10
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE) 会议论文  OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment  the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However  the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above  this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror  semiconductor lasers as light source and CCD sensor as receiver. The system is smaller  lighter  and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning  the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.  
A small thickness measurement system based on PSD and FPGA (EI CONFERENCE) 会议论文  OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:  
Guo J.;  Guo J.;  He X.
收藏  |  浏览/下载:30/0  |  提交时间:2013/03/25
Considering that the requirement of industrial manufacture  An AT89S51 singlechip works as the core processor of the system. By two laser triangulation  a small thickness measurement system based on PSD and FPGA is presented. It takes S3931 PSD of one dimension as position detection device  A FPGA produces logic control signals for the whole system  the small displacement is converted to differential voltages  which is made by Hamamatsu in Japan  and after amplification and A/D transformation  8-bit parallel data is send to singlechip from FPGA by external interrupts  and the final calculation results output to the LCD display module. After digital micro meter calibration  we get the small thickness. Experiments show that the detection accuracy of the system is not less than 10um.  
The calibration of faint simulation star magnitude based on single photon count technique (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Advances in Imaging Detectors and Applications, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Xu S.-Y.;  Guo J.;  Guo J.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
A calibration method of faint star magnitude of the star scene simulation device is proposed in this paper. In the research of simulation star magnitude  luminometers and CCD devices are the general calibration devices which are used to measure the illumination intensity and calibrate its magnitude. But if the simulation magnitude is only sixth magnitude  its illumination intensity is only 1.010-8 Lux. This illumination intensity level is the lowest illumination intensity that the commercial luminometer can detect. Hence the simulation star magnitude lower than six magnitude cannot be calibrated by luminoters. Likewise CCD devices also need an additive cooler in this case. When the single photon characteristic is presented due to the low luminosity of simulating light sources  the simulation star magnitude can be calibrated by detecting its photon flux of radiation with the method of single photon count. In this paper the detection principle of single photon based on a compact designed PMT detecting of the radiation level of simulation star magnitude is advanced. Especially a spectrum match method is proved theoretically to be an effective means for selecting PMT photosensitive type. In the case of the detection object of the simulation star in visible wavelength  a analysis indicates that the material of tri-alkali cathode materials its best choice after being compared the Signal-to-Noise of photon detector of several PMT photosensitive materials based on the different spectrum match ratio of different object light sources and different cathode materials. An experiment is employed to show the relationship of control voltage of PMT and its dark counter  the relationship of the environment temperature of PMT and its dark counter  which proves its only decades of CPS at room temperature. The so low dark counter avoids a bulky cooler and is convenient for installing it on the star scene simulation equipment. Finally in the experiment of calibrating the simulation star magnitudes the ability of its calibration is confirmed to reaches up to 12m  meanwhile its calibration error is within 0.2m. 2009 SPIE.  
A Novel Wavelength Calibration For Fiber-Optical Spectrographs Based On The Grating-Diffractive Equation 期刊论文  OAI收割
Applied Spectroscopy, 2008, 页码: 819-823
作者:  
Peng ZM(彭志敏);  Yang QS(杨乾锁);  Liu C(刘春);  Zhu NY(竺乃宜);  Jiang ZL(姜宗林)
收藏  |  浏览/下载:661/57  |  提交时间:2009/08/03
Research on the radiometric calibration of TDI CCD remote camera (EI CONFERENCE) 会议论文  OAI收割
ICO20: Illumination, Radiation, and Color Technologies, August 21, 2005 - August 26, 2005, Changchun, China
Liu Y.-X.; Hao Z.-H.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
Review of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study 期刊论文  OAI收割
AQUATIC TOXICOLOGY, 2002, 卷号: 60, 期号: 2015-01-02, 页码: 139-153
作者:  
Lu, YB;  Wang, ZJ;  Huckins, J
收藏  |  浏览/下载:14/0  |  提交时间:2015/11/19