中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [3]
寒区旱区环境与工程研... [1]
过程工程研究所 [1]
采集方式
OAI收割 [4]
iSwitch采集 [1]
内容类型
会议论文 [3]
期刊论文 [2]
发表日期
2019 [1]
2015 [1]
2010 [1]
2001 [1]
2000 [1]
学科主题
Materials ... [1]
Science & ... [1]
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Coordination of stomatal control and stem water storage on plant water use in desert riparian trees
期刊论文
iSwitch采集
TREES-STRUCTURE AND FUNCTION, 2019, 卷号: 33, 期号: 3, 页码: 787-801
作者:
Yu, Tengfei
;
Feng, Qi
;
Si, Jianhua
;
Pinkard, Elizabeth A.
收藏
  |  
浏览/下载:95/0
  |  
提交时间:2019/10/08
Stem water storage
Stomatal control
Stem diameter variations
Sap flow
Riparian forest
Populus
Modulating the Morphology and Electrical Properties of GaAs Nanowires via Catalyst Stabilization by Oxygen
期刊论文
OAI收割
ACS APPLIED MATERIALS & INTERFACES, 2015, 卷号: 7, 期号: 9, 页码: 5591-5597
作者:
Han, Ning
;
Yang, Zaixing
;
Wang, Fengyun
;
Yip, SenPo
;
Dong, Guofa
收藏
  |  
浏览/下载:38/0
  |  
提交时间:2015/05/12
GaAs nanowire
oxygen
diameter control
electronic property
CMOS inverter
Research on automatic Hartmann test of membrane mirror (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang P.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
Electrostatic membrane mirror is ultra-lightweight and easy to acquire a large diameter comparing with traditional optical elements
so its development and usage is the trend of future large mirrors. In order to research the control method of the static stretching membrane mirror
the surface configuration must be tested. However
membrane mirror's shape is always changed by variable voltages on the electrodes
and the optical properties of membrane materials using in our experiment are poor
so it is difficult to test membrane mirror by interferometer and null compensator method. To solve this problem
an automatic optical test procedure for membrane mirror is designed based on Hartmann screen method. The optical path includes point light source
CCD camera
splitter and diffuse transmittance screen. The spots' positions on the diffuse transmittance screen are pictured by CCD camera connected with computer
and image segmentation and centroid solving is auto processed. The CCD camera's lens distortion is measured
and fixing coefficients are given to eliminate the spots' positions recording error caused by lens distortion. To process the low sampling Hartmann test results
Zernike polynomial fitting method is applied to smooth the wave front. So low frequency error of the membrane mirror can be measured then. Errors affecting the test accuracy are also analyzed in this paper. The method proposed in this paper provides a reference for surface shape detection in membrane mirror research. 2010 Copyright SPIE - The International Society for Optical Engineering.
The room-temperature lasing of microdisk lasers (EI CONFERENCE)
会议论文
OAI收割
Optoelectronics, Materials, and Devices for Communications, November 12, 2001 - November 15, 2001, Beijing, China
作者:
Lin J.
;
Wang L.
;
Wang L.
;
Wang L.
;
Liu Y.
收藏
  |  
浏览/下载:38/0
  |  
提交时间:2013/03/25
Multiple quantum wells (MQW) microdisk lasers are fabricated by using the methods of photolithography-etching techniques. By the CCD watching-control and micron-area detecting systems
the 5m-diameter microdisk lasers was optically pumped by Ar+ pulse laser at room temperature
with the 1:50 pump duty cycle. We obtained the single-mode lasing at 1.543m wavelength
with threshold pump power about 200w.
Recent progress on asphere manufacturing and testing at CIOM (EI CONFERENCE)
会议论文
OAI收割
Advanced Optical Manufacturing and Testing Technology 2000, November 1, 2000 - November 3, 2000, Chengdu, China
作者:
Zhang X.
;
Yu J.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
The manufacturing procedure of a 500 mm in diameter
f/2 hyperbolic primary mirror based on Computer-Controlled Polishing is introduced in detail. The mirror was finally polished to the shape accuracy of 13 nm rms and the surface roughness of 2 nm Ra. Testing methods and data analysis for different stages ranging from grinding to polishing are discussed. Some critical factors affecting the efficiency and accuracy of the grinding/polishing procedure are summarized. In addition
the preliminary work to make large off-axis asphere mirrors is presented. The difficulties in polishing and testing for both circular aperture and rectangular aperture mirrors are previewed
and a possible solution is given. To control the geometrical parameters such as radius of curvature and conic constant
a new profiler has been built
and it has proven very useful to improve the grinding efficiency. Finally
the manufacturing of small aspheres using deterministic grinding tool is also introduced. The fine grinding procedure of LOH's asphere grinding machine is presented.