A fatigue limit evaluation method based on plastic strain incremental energy dissipation theory
期刊论文
OAI收割
ENGINEERING FRACTURE MECHANICS, 2023, 卷号: 282, 页码: 109173
作者:
Zu, Ruili
;
Zhu, Yingbin
;
Huang XF(黄先富)
;
Huang, Yao
;
Zhou, Yizhou
  |  
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2023/04/20
Fatigue limit
Plastic strain incremental energy dissipation
theory
Infrared thermal imaging
Digital image correlation
Calculating model for equivalent thermal defocus amount in infrared imaging system
期刊论文
OAI收割
Infrared Physics and Technology, 2016, 卷号: 74, 页码: 72-80
作者:
Zhang CS(张程硕)
;
Shi ZL(史泽林)
;
Xu BS(徐保树)
;
Feng B(冯斌)
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2016/01/30
Infrared imaging system
Thermal effect
Wave aberration
Defocus
Athermalization
Land surface emissivity retrieval from satellite data
SCI/SSCI论文
OAI收割
2013
作者:
Qiu S.
;
Wu H.
收藏
  |  
浏览/下载:65/0
  |  
提交时间:2014/12/24
thermal infrared data
airborne imaging spectrometer
reflection
radiometer aster
2-step physical algorithm
m atmospheric window
remote-sensing data
mu-m
directional emissivity
bidirectional
reflectance
split-window
A Low-Toxic Multifunctional Nanoplatform Based on Cu9S5@mSiO(2) Core-Shell Nanocomposites: Combining Photothermal- and Chemotherapies with Infrared Thermal Imaging for Cancer Treatment
期刊论文
OAI收割
ADVANCED FUNCTIONAL MATERIALS, 2013, 卷号: 23, 期号: 35, 页码: 4281-4292
作者:
Song, GS
;
Wang, QA
;
Wang, Y
;
Lv, G
;
Li, C
收藏
  |  
浏览/下载:48/0
  |  
提交时间:2015/07/22
low-toxicity materials
photothermal therapy
chemotherapy
infrared thermal imaging
In situ observation of thermal Marangoni convection on the surface of a sessile droplet by infrared thermal imaging
期刊论文
OAI收割
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2012, 卷号: 26, 期号: 12-17, 页码: 2177-2188
作者:
Wang ZQ(王子千)
;
Zhao YP(赵亚溥)
;
Zhao, YP
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/01/18
Electrowetting
Marangoni convection
sessile droplet
infrared thermal imaging
Evaporation
Forces
Mass
Comparison of radiation temperature measurement precision between middlewave and longwave thermal-imaging systems (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
作者:
Sun Z.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
A comparison study on temperature measurement precision between middlewave 3-5m and longwave 8-12m measuring thermal imaging systems has been conducted. The study was limited to systems working in indoor conditions and the target's temperature is in the range of 270K900K. First
the Disturb Resisting Function (DRF) of infrared systems is deduced. On the base of DRF curve
we find that the middlewave infrared system get the smaller influences under the same size disturb compared with the longwave system. A theory of the influence of target's physical characteristic and measurement conditions on the accuracy of temperature measurements has been developed. On the basis of the developed formulas an analysis of the influence of signal disturbances (because of incorrectly assumed emissivity
limited transmittance of the atmosphere
radiation reflected by the object and shift of optics radiation) on the accuracy of temperature measurement has been made. It has been found that the middlewave systems in typical temperature range offer generally better accuracy in temperature measurement than the longwave ones do. 2012 IEEE.
Design of reimaging F/1.0 long-wavelength infrared optical system (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
A reimaging F/1.0 long-wavelength infrared optical system is proposed. The design has a flexible opto-mechanical layout. The design process is as follows. Firstly
the catadioptric reimaging system consists of two reflecting mirrors and a relay lenses. Two reflecting mirrors make up of the first imaging system and are therefore free of chromatic aberrations
while low dispersion lenses were used in the reimaging system
so the optical system do not need achromatic design for a high image quality. Then
to correct high-order aberrations resulting from large relative aperture
more parameters need to be used with aspheric or diffractive surfaces due to modern optic technology development. Here
aspheric is selected for easily manufacture. Finally
the design is completed with the help of ZEMAX software. The effective focal length of the objective is 120mm and the field of view (FOV) is 4. The simulated final design shows adequate image quality and the modulation transfer function (MTF) is close to diffraction limit. The effect of the surrounding environmental temperature is analyzed using the concept of thermal defocusing
and the thermal compensation is discussed. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Accurate measuring temperature with infrared thermal imager in the unstable condition of ambient temperature
会议论文
OAI收割
2011 international conference on optical instruments and technology: optoelectronic measurement technology and systems, beijing, china, november 6, 2011 - november 9, 2011
WangJing
;
QuEn-Shi
;
CaoJian-Zhong
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2012/07/09
infrared thermal imaging system
temperature measurement
blackbody
unstable condition
Thermal difference analysis and athermalization design of infrared optical system (EI CONFERENCE)
会议论文
OAI收割
Optical Design and Testing IV, October 18, 2010 - October 20, 2010, Beijing, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
When infrared optical system works in a large temperature range
the thermal effect of optical lens and optical tube will produce image plane shift and lead to imaging quality deterioration. In order to eliminate the thermal aberration
the athermalization design principles of infrared optical system were introduced
and some commonly used methods of thermal difference compensation were described. Proceeding from single lens
the thermal difference caused by temperature changing was analyzed
and the relationship between temperature and focus shift was obtained. Considering optical tube thermal expansion
a set of equations to estimate the thermal difference of lens group was given. Finally
an infrared optical imaging system that can work under the temperature range of -40C to 60C was design according to athermal technique
in which a new mechanical passive temperature compensation was proposed. Through simulation
the athermalization design could make imaging plane shift the smallest. The simulation results coincided with the theoretical formula
and the design had reference value in engineering. 2010 Copyright SPIE - The International Society for Optical Engineering.
Athermal design of hybrid refractive/harmonic diffractive optical system for far-infrared multi-band (EI CONFERENCE)
会议论文
OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Advanced Optical Manufacturing Technologies, November 19, 2008 - November 21, 2008, Chengdu, China
作者:
Liu Y.
;
Liu Y.
;
Zhang H.
;
Zhang H.
;
Sun Q.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
In order to get enough information about the target
avoid big chromatic aberration as a result of wide spectrum and the complexity of optical system and adapt different special environment temperature
a hybrid refractive/harmonic diffractive optical system in far-infrared multi-band is described in the paper. This diffractive optical system has been designed an athermalized multi-band imaging system with harmonic diffractive element in 15-50m spectrum
based on larger 1dispersion capability and particular thermal dispersive power of harmonic diffractive element. Then
at the temperature range from 0C to 40C
this design can simultaneously meet with all requirements of the imaging system in five harmonic wave bands
including15.8-16.2m
18.5-20m
23-25m
30.5-33.5m and 46-50m. In each harmonic wave band
the magnification changes as a function of wavelength
which creates image registration error. To compensate this shortcoming
a zoom optical system is designed with three lenses by means of optical two- component method. The design results show that the hybrid refractive/harmonic diffractive optical system can realize athermalized and achromatic design
and the zoom optical system makes half image height at 3.53mm in every harmonic wave band and still realizes aberration compensation action. In the five harmonic wave bands
each optical transfer function approaches the diffraction limit at ambient temperature range of 0C to 40C. Finally
the system realizes the requirements of portability
mini-type and ease for fabrication. 2009 SPIE.