中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共4条,第1-4条 帮助

条数/页: 排序方式:
Signal fluctuation suppression in confocal measurements by laser modulation and power monitoring 期刊论文  OAI收割
MEASUREMENT, 2023, 卷号: 214, 页码: 8
作者:  
Wang, Shaoyi;  Li, Shoujie;  Ye, Wangquan;  Song, Wenhua;  Zhang, Xuanbo
  |  收藏  |  浏览/下载:21/0  |  提交时间:2023/12/13
高光谱成像激光雷达系统辐射定标和地物信息获取 期刊论文  OAI收割
光学学报, 2020, 卷号: 40
作者:  
钱立勇;  吴德成;  周晓军;  钟刘军;  魏巍
  |  收藏  |  浏览/下载:52/0  |  提交时间:2020/10/26
Research on 10.6 m laser beam monitoring in CO2 laser processing system (EI CONFERENCE) 会议论文  OAI收割
Infrared Materials, Devices, and Applications, November 12, 2007 - November 15, 2007, Beijing, China
作者:  
Gao Y.;  Shao S.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
It is a key point of CO2 laser beam monitoring in the CO 2 laser processing system to achieve alignment between CO2 laser and PL (pointing and launching) system. By monitoring the angle offset of CO2 laser beam  the compensation can be gotten witch is given to fast-steering mirror to rectify the direction of laser beam. But the normal photoelectric detector can not get the laser signal because of CO2 laser's high energy and long wavelength. Its wavelength is 10.6m and its power can reach kW level. Consequently  it is difficult to detect the high-energy 10.6m laser beam directly. So  we monitored the output mirror of laser resonator superseded the laser beam  indirectly. The laser beam monitoring system could be designed based on CCD laser auto-collimation angular measurement principle and image processing method. In this paper  application of CCD laser auto-collimation angular measurement principle and image processing method for CO2 laser beam monitoring system is introduced particularly  After design  fabrication and alignment  the monitoring system can be used for experimental study that including angular measurement accuracy and angle offset measurement of CO2 laser beam. Angle offset range and angle variation rule of CO2 laser beam is also can be acquired for further research.  
Optical thin films for high power LD-pumped Nd:YVO4 457nm blue laser (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Design and Fabrication, August 21, 2005 - August 26, 2005, Changchun, China
Bu Y.; Zheng Q.; Xue Q.; Qian L.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
The expanding field of LD-pumped solid state lasers forms an extraordinary challenge for developing the optical coatings. Optical thin films for LD-pumped Nd:YVO4/LBO blue laser at 457nm was presented in this paper based on lower gain laser line action theory  including spectral beam dividers and doubling antireflecting multilayer coatings. To achieve 914nm laser action and 457nm blue light high output power  the coating specifications of laser resonator was analyzed. The transmittance/reflectance spectrum request was effectively separated by adopting high tuned radio stack  simultaneously the spectrum request was reasonably distributed on the two resonator facet reflectivity for restrain the other laser lines such as1064nm and1342nm. The dielectric high reflective laser mirror and antireflecting coatings for 457nm laser were manufactured by double ion beam sputtering technique  which is controlled by a time-power monitoring. Using type-I critical phase-matching LBO crystal  457nm blue laser is obtained by 914nm intracavity frequency doubling. The maximum laser output power of 1.5W is obtained when incident pump laser of 15W is used.