中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
数学与系统科学研究院 [3]
长春光学精密机械与物... [2]
计算技术研究所 [1]
自动化研究所 [1]
植物研究所 [1]
采集方式
OAI收割 [8]
内容类型
期刊论文 [6]
会议论文 [2]
发表日期
2024 [1]
2023 [1]
2022 [1]
2018 [2]
2017 [1]
2006 [2]
更多
学科主题
Agricultur... [1]
筛选
浏览/检索结果:
共8条,第1-8条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
A 16-Gb/s 3-tap adaptive DFE in 12-nm FinFET CMOS technology
期刊论文
OAI收割
MICROELECTRONICS JOURNAL, 2024, 卷号: 149, 页码: 10
作者:
Sun, Xinzhuo
;
Ding, Jianping
;
Yang, Liqiong
;
Lin, Changlong
;
Li, Yao
  |  
收藏
  |  
浏览/下载:2/0
  |  
提交时间:2024/12/06
Decision feedback equalizers (DFEs)
Adaptive equalization
Regenerating sampler (RG-Sampler)
Sign-sign least-mean-squares (SSLMS)
2-D eye-opening monitor (EOM)
Receiver
Unsupervised model adaptation for multivariate calibration by domain adaptation-regularization based kernel partial least square
期刊论文
OAI收割
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 卷号: 292, 页码: 17
作者:
Shan, Peng
;
Bi, Yiming
;
Li, Zhigang
;
Wang, Qiaoyun
;
He, Zhonghai
  |  
收藏
  |  
浏览/下载:14/0
  |  
提交时间:2023/11/17
Model adaptation
Domain-invariant feature representation
Projected maximum mean discrepancy
Kernel partial least squares
A Note on the Convergence of Distributed RLS
期刊论文
OAI收割
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2022, 卷号: 67, 期号: 12, 页码: 6762-6769
作者:
Liu, Zhaobo
;
Li, Chanying
  |  
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2023/02/07
Distributed estimation
mean square convergence
noises
recursive least squares
strong consistency
Analysis of Distributed Adaptive Filters Based on Diffusion Strategies Over Sensor Networks
期刊论文
OAI收割
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2018, 卷号: 63, 期号: 11, 页码: 3643-3658
作者:
Xie, Siyu
;
Guo, Lei
  |  
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2019/01/11
Diffusion strategies
distributed adaptive filters
least mean squares
stochastic stability
tracking performance
ANALYSIS OF NORMALIZED LEAST MEAN SQUARES-BASED CONSENSUS ADAPTIVE FILTERS UNDER A GENERAL INFORMATION CONDITION
期刊论文
OAI收割
SIAM JOURNAL ON CONTROL AND OPTIMIZATION, 2018, 卷号: 56, 期号: 5, 页码: 3404-3431
作者:
Xie, Siyu
;
Guo, Lei
  |  
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2019/01/11
distributed adaptive filter
consensus algorithm
least mean squares
information condition
stochastic stability
tracking performance
Pollen-based reconstructions of Late Holocene climate on the southern slopes of the central Tianshan Mountains, Xinjiang, NW China
期刊论文
OAI收割
INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2017, 卷号: 37, 期号: 4, 页码: 1814-1823
作者:
Zhang, Yun
;
Kong, Zhaochen
;
Yang, Zhenjing
  |  
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2022/03/28
surface pollen
fossil pollen
weighted averaging partial least squares regression method
mean annual precipitation
mean annual temperature
Tianshan Mountains
The study on the near infrared spectrum technology of sauce component analysis (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Information Processing, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Li S.
;
Wang C.
;
Chen X.
;
Chen X.
;
Chen X.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
The author
Shangyu Li
engages in supervising and inspecting the quality of products. In soy sauce manufacturing
quality control of intermediate and final products by many components such as total nitrogen
saltless soluble solids
nitrogen of amino acids and total acid is demanded. Wet chemistry analytical methods need much labor and time for these analyses. In order to compensate for this problem
we used near infrared spectroscopy technology to measure the chemical-composition of soy sauce. In the course of the work
a certain amount of soy sauce was collected and was analyzed by wet chemistry analytical methods. The soy sauce was scanned by two kinds of the spectrometer
the Fourier Transform near infrared spectrometer (FT-NIR spectrometer) and the filter near infrared spectroscopy analyzer. The near infrared spectroscopy of soy sauce was calibrated with the components of wet chemistry methods by partial least squares regression and stepwise multiple linear regression. The contents of saltless soluble solids
total nitrogen
total acid and nitrogen of amino acids were predicted by cross validation. The results are compared with the wet chemistry analytical methods. The correlation coefficient and root-mean-square error of prediction (RMSEP) in the better prediction run were found to be 0.961 and 0.206 for total nitrogen
0.913 and 1.215 for saltless soluble solids
0.855 and 0.199 nitrogen of amino acids
0.966 and 0.231 for total acid
respectively. The results presented here demonstrate that the NIR spectroscopy technology is promising for fast and reliable determination of major components of soy sauce.
Fast determination of total ginsenosides content in Ginseng powder by near infrared reflectance spectroscopy (EI CONFERENCE)
会议论文
OAI收割
ICO20: Biomedical Optics, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Chen X.-D.
;
Chen X.-D.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
Near infrared (NIR) reflectance spectroscopy was used to develop a fast determination method for total ginsenosides in Ginseng (Panax Ginseng) powder. The spectra were analyzed with multiplicative signal correction (MSC) correlation method. The best correlative spectra region with the total ginsenosides content was 1660 nm1880 nm and 2230nm-2380 nm. The NIR calibration models of ginsenosides were built with multiple linear regression (MLR)
principle component regression (PCR) and partial least squares (PLS) regression respectively. The results showed that the calibration model built with PLS combined with MSC and the optimal spectrum region was the best one. The correlation coefficient and the root mean square error of correction validation (RMSEC) of the best calibration model were 0.98 and 0.15% respectively. The optimal spectrum region for calibration was 1204nm-2014nm. The result suggested that using NIR to rapidly determinate the total ginsenosides content in ginseng powder were feasible.