Topology and parametric optimization based lightweight design of a space reflective mirror
期刊论文
OAI收割
Optical Engineering, 2018, 卷号: 57, 期号: 7, 页码: 12
作者:
Liu, G.
;
Guo, L.
;
Wang, X. T.
;
Wu, Q. W.
  |  
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2019/09/17
lightweight mirrors
optomechanics
space optics
optimization design
telescope
Optics
Design and test of pointing mirror assembly for spaceborne remote sensing camera (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronics, Communications and Control, ICECC 2011, September 9, 2011 - September 11, 2011, Ningbo, China
作者:
Chen W.
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2013/03/25
In order to ensure the surface figure of the pointing mirror (460mm long
290mm wide) in spaceborne remote sensing camera
Silicon Carbide was selected as the mirror material. The form of composite triangular and rectangular and the combination of open and closed back was explored in the lightweight design. A new kinematic mount and flexible structure in axis is used to hold the mirror around the lateral surface. The structure can minimize distortions induced by coefficient of thermal expansion mismatch among the materials. This eliminates the bending of the integral mount under the weight of the mirror. Optical performance of the mirror was analyzed under gravity load and temperature load using finite element method. Predicted surface figure error based on the removal of bias
tilt and power was calculated using an in-house Matlab script for mirrors. The pointing mirror assembly was tested using open loop servo control. And the surface figure was checked using interferometer. Surface figure accuracy is better than 1/30 ( 632.8nm
rms). The results show that the kinematic mount induces minimal figure error on the optical surface. 2011 IEEE.
Research on automatic Hartmann test of membrane mirror (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang P.
收藏
  |  
浏览/下载:41/0
  |  
提交时间:2013/03/25
Electrostatic membrane mirror is ultra-lightweight and easy to acquire a large diameter comparing with traditional optical elements
so its development and usage is the trend of future large mirrors. In order to research the control method of the static stretching membrane mirror
the surface configuration must be tested. However
membrane mirror's shape is always changed by variable voltages on the electrodes
and the optical properties of membrane materials using in our experiment are poor
so it is difficult to test membrane mirror by interferometer and null compensator method. To solve this problem
an automatic optical test procedure for membrane mirror is designed based on Hartmann screen method. The optical path includes point light source
CCD camera
splitter and diffuse transmittance screen. The spots' positions on the diffuse transmittance screen are pictured by CCD camera connected with computer
and image segmentation and centroid solving is auto processed. The CCD camera's lens distortion is measured
and fixing coefficients are given to eliminate the spots' positions recording error caused by lens distortion. To process the low sampling Hartmann test results
Zernike polynomial fitting method is applied to smooth the wave front. So low frequency error of the membrane mirror can be measured then. Errors affecting the test accuracy are also analyzed in this paper. The method proposed in this paper provides a reference for surface shape detection in membrane mirror research. 2010 Copyright SPIE - The International Society for Optical Engineering.