GRANDMA and HXMT Observations of GRB 221009A: The Standard Luminosity Afterglow of a Hyperluminous Gamma-Ray Burst-In Gedenken an David Alexander Kann
期刊论文
OAI收割
Astrophysical Journal Letters, 2023, 卷号: 948, 期号: 2, 页码: L12
作者:
Kann, D. A.
;
Agayeva, S.
;
Aivazyan, V.
;
Alishov, S.
;
Andrade, C. M.
  |  
收藏
  |  
浏览/下载:1/0
  |  
提交时间:2024/06/23
optical light-curve
supernova 2003dh
extinction map
star merger
pre-swift
long
emission
grb-030329
telescope
evolution
Astronomy & Astrophysics
Novel fast measurement method of twist angle and optical retardation of liquid crystal display (EI CONFERENCE)
会议论文
OAI收割
Asia Display 2007, AD'07, March 12, 2007 - March 16, 2007, Shanghai, China
Huang X.
;
Lu Y.-T.
;
Kong X.-J.
;
Jing H.
;
Fu G.-Z.
;
Jin H.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
A novel method is proposed to measure twist angle and optical retardation of liquid crystal display in this paper. The new method which is one of single-wavelength methods has three characteristics
introducing a method of measuring the total intensity ratio of the transmitted light to eliminate the influence of absorption by the polarizer
using circularly and homogeneously aligned LC cell (CH-LC) as a unique polarization-converting device
analyzer
using variable sector diaphragm and photodetector to detect the total intensity of transmitted light whose original polarization direction is continuously changed from 0 to arbitrary angle
CH-LC
liquid crystal display and so on. The twist angle () and optical retardation (nd) can be derived by using Jones matrix analysis and a curve fitting where and nd are fitting parameters. Experiment proved the results are accurate
the process of operation is fast
the devices are economical.
A study of the light curve periodic behavior of BL Lac object S5 0716+714
期刊论文
OAI收割
ACTA PHYSICA SINICA, 2007, 卷号: 56, 期号: 7, 页码: 4305
作者:
Zhang HJ(张皓晶)
;
Zhang X(张雄)
  |  
收藏
  |  
浏览/下载:13/0
  |  
提交时间:2021/12/06
UNEQUALLY-SPACED DATA
RAY-LOUD BLAZARS
OPTICAL VARIABILITY
GAMMA-RAY
CCD PHOTOMETRY
BLACK-HOLE
S5-0716+714
OJ-287
BL Lac object S5 0716+714
light curve variation period
method of power spectrum
Research on the nonuniformity correction of linear TDI CCD remote camera (EI CONFERENCE)
会议论文
OAI收割
Advanced Materials and Devices for Sensing and Imaging II, November 8, 2004 - November 10, 2004, Beijing, China
Ya-xia L.
;
Zhi-hang H.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
Many applications
such as industrial inspection and overhead reconnaissance benefit from line scanning architectures where time delay integration (TDI) significantly improves sensitivity[5]. Images with linear response have become the backbone of the imaging industry. But each pixel of the TDI CCD has unique light sensitivity characteristics. Because these characteristics and the lens of the optical system affect camera's linearization and its performance
they must be removed through calibration. The process by which a CCD image is calibrated is known as nonuniformity correction. This paper discusses several methods of nonuniformity correction[2]. The first is one-point correction technique
which requires only one calibration point. This approach is to shift each curve toward the nominal curve by subtracting the offset from or adding the offset to the average. The second is two-point correction technique
which requires two calibration points. Each point is rotated and aligned so that all the detectors have the same response under the same radiance. The third is multipoint correction. It is recommended that more calibration points be implemented at appropriate regions of the response curve. Depend on the linear photoelectric response of the TDI CCD
we use two-point calibration and the standard deviations for the images are given before and after the correction.