中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
Design, fabrication and testing of duralumin zoom mirror with variable thickness 会议论文  OAI收割
international symposium on advanced optical design and manufacturing technologies / international symposium on astronomical telescope and instrumentation, beijing, peoples r china, 2016-05-09
作者:  
Zhao, Hui;  Xie, Xiaopeng;  Xu, Liang;  Ding, Jiaoteng;  Shen, Le
收藏  |  浏览/下载:29/0  |  提交时间:2017/03/20
Calibration of optical center displacement for Zooming image 会议论文  OAI收割
2015 IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), Shenyang, China, June 8-12, 2015
作者:  
Gao HW(高宏伟);  Wei, Qiuyang;  Yu Y(于洋);  Liu JG(刘金国)
收藏  |  浏览/下载:23/0  |  提交时间:2015/12/24
All-reflective optical bifocal zooming system without moving elements based on deformable mirror for space camera application 期刊论文  OAI收割
applied optics, 2013, 卷号: 52, 期号: 6, 页码: 1192-1210
作者:  
Zhao, Hui;  Fan, Xuewu;  Zou, Gangyi;  Pang, Zhihai;  Wang, Wei
收藏  |  浏览/下载:26/0  |  提交时间:2014/01/14
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Wang L.-J.;  Zhang J.-P.;  Wang L.-J.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1  Second  Others  zoom ratio =1:4  binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate  in order to balance 5th spherical aberration  and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First  5th coma aberration and 5th astigmatic aberration  the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner  high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited  both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm  MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm  MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046  the coma aberration 0.055 and astigmatic aberration 0.034.  
Narcissus analysis for cooled staring IR system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
Narcissus can have a deleterious effect on image quality for cooled infrared imaging systems. Therefore  analysis of narcissus is important for designing both scanning and staring optics. Narcissus is generally assumed to be negligible in staring IR optical designs because the shading effects can be removed by calibration of the detector array data. However  the calibration usually decreases sensitiveness of the system and Narcissus variation may be noticeable for sensors when the conditions changes as follows: 1. warming and cooling the optical housing  2. zooming optical elements  3. movement of lenses for focus. In that case  it will result in shading and other image defects even after calibration. To minimize these effects  narcissus should be assessed and controlled during the design of staring array IR system. We provided a direct and fast method for analyzing the narcissus variation in the presence of software such as LightTools  TracePro and ASAP  and proposed the principles in optical design of staring IR systems to reduce narcissus. A cooled staring IR system with serious narcissus was estimated and reoptimized. Narcissus analysis of this IR system confirmed the efficiency of the analysis method.  
Research of automatic test technology of parameters used in a dual-CCD TV measure-system (EI CONFERENCE) 会议论文  OAI收割
2nd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 2, 2005 - November 5, 2005, Zian, China
作者:  
Wang L.;  Li Y.;  Li Y.;  Li Y.;  Li Y.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
This paper describes a kind of automatic test technology of the parameters used in a dual-CCD TV measure-system (TV -MS) .The TV -MS is the ground control equipment of the anti-tank missile and integrates the technologies of optical  machine and electronics. It is important and key component. The main technical parameters of the TV -MS are field of view  zero point  precision  sensitivity  anti-jamming ability  zooming time and focus time  etc. To insure the TV -MS satisfying the tactical and technical requirements and discover fault and reason  a fast and accurate equipment satisfying the test technical parameters of the TV -MS is urgently needed in manufacture and service. Firstly  the parameter test system converted optical signal to electronic signal  implemented automatic control of the invariant illumination of parallel pipeline output. Secondly  data and command delivering  displaying or printing are realized by using 80C196KB. The experiment result shows that the approach of automatic testing of the Parameters used in a dual-CCD TV -MS is successful and it can be used for all tests of the functions and parameters of the TV -MS. The main innovations are to realize the fast  veracious measure of technical parameters of the dual-CCD TV-MS  and integrate the technologies of optics  machineries and electronics. An advanced means is provided to judge the technical states  find malfunctions and discover the reasons in producing and maintaining process. The equipment suited for anti-tank missile systems is given.