中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共11条,第1-10条 帮助

条数/页: 排序方式:
An Iterative High-Precision Algorithm for Multi-Beam Array Stitching Method Based on Scanning Hartmann 期刊论文  OAI收割
APPLIED SCIENCES-BASEL, 2024, 卷号: 14, 期号: 2
作者:  
Yan, Xiangyu;  Li, Dahai;  Kewei, E.;  Feng, Fang;  Wang, Tao
  |  收藏  |  浏览/下载:20/0  |  提交时间:2024/03/04
Computer-aided alignment method for AIMS solar telescope 会议论文  OAI收割
Shanghai, China, 2021-10-28
作者:  
E., Kewei
  |  收藏  |  浏览/下载:37/0  |  提交时间:2022/03/18
Sub-aperture optical system testing by using of a modified simulateous fit method 会议论文  OAI收割
Shanghai, China, 2020-06-29
作者:  
Kewei, E.;  Zhao, Jianke;  Wang, Tao;  Wang, Zhengfeng;  Liu, Kai
  |  收藏  |  浏览/下载:35/0  |  提交时间:2021/03/04
Orthonormal polynomials in segmented optical pupils 期刊论文  OAI收割
Optik, 2019, 卷号: 197
作者:  
Zhang, Yongfeng;  Xian, Hao
  |  收藏  |  浏览/下载:28/0  |  提交时间:2021/05/06
A precise method for adjusting the optical system of laser sub-aperture 会议论文  OAI收割
Nanjing, PEOPLES R CHINA, 2017-10-24
作者:  
Song Xing;  Zhang Xue-min;  Yang Jianfeng;  Xue Li;  Yang, JF (reprint author), Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Shaanxi, Peoples R China.
  |  收藏  |  浏览/下载:27/0  |  提交时间:2018/07/05
Development of testing convex hyperbolic mirror using Hindle method based on stitching technology 会议论文  OAI收割
Amsterdam, Netherlands, 2012-7-1
作者:  
Zi-bo Jiang;  Xin-nan Li;  Bo Ji
收藏  |  浏览/下载:31/0  |  提交时间:2014/01/09
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE) 会议论文  OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment  the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However  the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above  this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror  semiconductor lasers as light source and CCD sensor as receiver. The system is smaller  lighter  and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning  the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.  
MTF-based research on the minimum fill factor in optical sparse aperture system (EI CONFERENCE) 会议论文  OAI收割
2011 4th International Conference on Intelligent Computation Technology and Automation, ICICTA 2011, March 28, 2011 - March 29, 2011, Shenzhen, Guangdong, China
作者:  
Liu Z.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
Optical system of golay-3 synthetic aperture telescope of Fizeau style (EI CONFERENCE) 会议论文  OAI收割
2010 3rd International Conference on Advanced Computer Theory and Engineering, ICACTE 2010, August 20, 2010 - August 22, 2010, Chengdu, China
作者:  
Sun Z.-Y.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Design of 2.5m Optical Fabrication Machine for Astronomical Mirrors 会议论文  OAI收割
Marseille, France, 2008-6-23
作者:  
Da-xing Wang;  Yi Zheng;  Bin Liang;  Ying Li
收藏  |  浏览/下载:28/0  |  提交时间:2014/01/01