中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
工程热物理研究所 [1]
采集方式
OAI收割 [5]
内容类型
会议论文 [4]
期刊论文 [1]
发表日期
2012 [1]
2011 [1]
2010 [2]
1993 [1]
学科主题
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Thermal-optical analysis for optical window under high Mach flight condition (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
Zhong C.
;
Ding Y.
;
Fu J.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
When the airborne platform
where installed the optical window
is in high Mach flight condition. The aerodynamic heating effect
which will influence optical properties of optical window
becomes very obvious. This special flight condition will change shape
refractive index and also refractive index distribution of optical window due to the generated high axial temperature gradient. To ensure image quality of aerial remote sensor
the present paper does thermal-optical analysis for optical window under high Mach flight condition. Then
on this basis
do simulations according to theoretical analysis and boundary conditions derived from practical assumptions in order to get the final conclusions. 2012 IEEE.
Design and simulation of CMOS star sensor lens with large relative aperture and wide field (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Zhong X.
;
Jin G.
收藏
  |  
浏览/下载:67/0
  |  
提交时间:2013/03/25
A 50mm focal length
F/1.25
Gaussian type optical system is designed in this paper
which has 20field of view. Actual star image adding optical cross-talk effect of CMOS(Complementary Metal Oxide Semiconductor)
detector is simulated by non-sequential ray tracing in ZEMAX optical design and analysis software to evaluate its performance. The distortion relative to image spot centriod is introduced and calculated by simulated star images
which is less than 0.03% of lens in this paper. Thermal adaptability is discussed by opt-mechanic thermal analysis
which shows the RMS spot radius of marginal filed changes less than 0.7m under 10C temperature gradient
and changes less than 1m during homogeneous temperature changing from 40C to 40C. The results of analyses and simulations show the design of this lens can achieve the requirement of high precision CMOS star sensor well. 2011 IEEE.
The analysis of the large-diameter primary mirror deformation of surface figure in the temperature field (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Feng S.-L.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
The effect on the deformation of the primary mirror surface figure of the temperature gradient has been discussed theoretically. And its effect under axis and radial temperature gradient is analyzed when optical axis and support ways of the mirror changed. It has been concluded that the effect on the surface figure of the axis gradient is larger than radial gradient and also found that the deformation is concerned not only with thermal and structural parameter but also directly with the magnitude and direction of the temperature gradient. 2010 IEEE.
Influence of spatial temperature distribution on high accuracy interferometric metrology (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Yang H.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Yan F.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
We calculate the influence of temperature change on the refractive index of air
establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First
a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air
followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer
accompanied by a temperature change random function within each grid. Finally
all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position
angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result
the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus
to realize the high accuracy figure metrology
the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer. 2010 Copyright SPIE - The International Society for Optical Engineering.
Heat Transfer to a Particle Exposed to a RarefiedPlasma with a Great Temperature Gradient
期刊论文
OAI收割
JOURNAL OF THERMAL SCIENCE, 1993, 卷号: 2, 期号: 2, 页码: 135,142
Xi Chen
;
Xin Tao
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2013/03/13
particle heat transfer
rarefied plasma
temperature gradient effect