中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共25条,第1-10条 帮助

条数/页: 排序方式:
Rail Detection Based on LSD and the Least Square Curve Fitting 期刊论文  OAI收割
International Journal of Automation and Computing, 2021, 卷号: 18, 期号: 1, 页码: 85-95
作者:  
Yun-Shui Zheng;  Yan-Wei Jin
  |  收藏  |  浏览/下载:28/0  |  提交时间:2021/02/23
Measurement of moisture content in lubricating oils of high-speed rail gearbox by Vis-NIR spectroscopy 期刊论文  OAI收割
Optik, 2020, 卷号: 224
作者:  
Liu, Chenyang;  Tang, Xingjia;  Yu, Tao;  Wang, Taisheng;  Lu, Zhenwu
  |  收藏  |  浏览/下载:87/0  |  提交时间:2020/11/03
Research on the multichannel measurement system in the forest soil respiration 会议论文  OAI收割
2015 3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015), Guangzhou, China, June 27-28, 2015
作者:  
Wang ZP(王志平);  Xu AD(徐皑冬);  Song Y(宋岩);  Yan BJ(闫炳均);  Hu B(胡波)
收藏  |  浏览/下载:33/0  |  提交时间:2015/12/19
Research on the sensor calibration of pressure transmitter based on the least square method 会议论文  OAI收割
2014 12th IEEE International Conference on Signal Processing, ICSP 2014, Hangzhou, China, October 19-23, 2014
作者:  
Wang ZP(王志平);  Xu AD(徐皑冬);  Wang K(王锴);  Song Y(宋岩);  Yan BJ(闫炳均)
收藏  |  浏览/下载:30/0  |  提交时间:2015/08/23
Parameters estimation of BLDC motor for energy storage system (EI CONFERENCE) 会议论文  OAI收割
10th World Congress on Intelligent Control and Automation, WCICA 2012, July 6, 2012 - July 8, 2012, Beijing, China
Wu J.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
Reagentless near-infrared determination of cholesterol in undiluted human serum using interval partial least square (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Gao H.; Lu Q.; Huang F.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
In order to determination of cholesterol in human serum with no reagent using nearinfrared (NIR) spectroscopy. Interval partial least square (iPLS) was proposed as an effective variable selection approach for multivariate calibration. For this purpose  an independent sample set was employed to evaluate the prediction ability of the resulting model. The spectrum was split into different interval. Then  the informative region of cholesterol (1688-1760nm)  in which the PLS model has a low RMSEP with 0.241mmol/L and a high R with 0.975  is selected with 23 intervals. The results indicate that  the informative region of cholesterol can be obtained by iPLS and applied to design the simpler reagentless NIR instruments for inexpensive cholesterol measurement in future. (2012) Trans Tech Publications  Switzerland.  
AUTONOMOUS INTEGRATED NAVIGATION USING X-RAY PULSARS AND ASTEROIDS 会议论文  OAI收割
63rd International Astronautical Congress 2012, IAC 2012, Naples, Italy, 2012
Yang Chengwei; Gao Dong; Zheng Jianhua
收藏  |  浏览/下载:42/0  |  提交时间:2014/04/30
To improve the navigation performance of the spacecraft during interplanetary cruise  a novel integrated navigation system is proposed. For X-ray pulsar navigation (XNAV) is a hot and prospective research subject  and the optical navigation using asteroids is practical in space engineering  we designed an autonomous navigation system using one X-ray detector and one navigation camera. The measurement models of the XNAV based on the time difference of arrival and the optical navigation based on the images of asteroids are presented. To enhance practicality  the X-ray pulsars and asteroids are observed by turns. The batch least square filter  used by Deep Space I  is adopted to estimate the system state. The numerical simulation results show that the integrated navigation is feasible on the interplanetary cruise orbit. Moreover  compared with the XNAV and the optical navigation  the integrated navigation system can provide higher navigation performance.  
The ship-borne infrared searching and tracking system based on the inertial platform (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:  
Li Y.;  Zhang H.;  Zhang H.;  Li Y.;  Li Y.
收藏  |  浏览/下载:43/0  |  提交时间:2013/03/25
As a result of the radar system got interferenced or in the state of half silent  it can cause the guided precision drop badly In the modern electronic warfare  therefore it can lead to the equipment depended on electronic guidance cannot strike the incoming goals exactly. It will need to rely on optoelectronic devices to make up for its shortcomings  but when interference is in the process of radar leading  especially the electro-optical equipment is influenced by the roll  pitch and yaw rotation  it can affect the target appear outside of the field of optoelectronic devices for a long time  so the infrared optoelectronic equipment can not exert the superiority  and also it cannot get across weapon-control system "reverse bring" missile against incoming goals. So the conventional ship-borne infrared system unable to track the target of incoming quickly  the ability of optoelectronic rivalry declines heavily.Here we provide a brand new controlling algorithm for the semi-automatic searching and infrared tracking based on inertial navigation platform. Now it is applying well in our XX infrared optoelectronic searching and tracking system. The algorithm is mainly divided into two steps: The artificial mode turns into auto-searching when the deviation of guide exceeds the current scene under the course of leading for radar.When the threshold value of the image picked-up is satisfied by the contrast of the target in the searching scene  the speed computed by using the CA model Least Square Method feeds back to the speed loop. And then combine the infrared information to accomplish the closed-loop control of the infrared optoelectronic system tracking. The algorithm is verified via experiment. Target capturing distance is 22.3 kilometers on the great lead deviation by using the algorithm. But without using the algorithm the capturing distance declines 12 kilometers. The algorithm advances the ability of infrared optoelectronic rivalry and declines the target capturing time by using semi-automatic searching and reliable capturing-tracking  when the lead deviation of the radar is great. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
Research of active supporting technology based on 400mm thin mirror (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Liu X.-Y.;  Wang J.-L.;  Wang J.-L.;  Liu X.-Y.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
Using a spherical mirror of 400mm diameter and 12mm thickness  active supporting technology of thin mirror is researched. The axial support of the mirror is composed of 12 active supports and 3 fixed supports. The force actuator  which is composed of displacement actuator and force sensor  is installed in the active support. The mirror surface is tested by Zygo interferometer. For calibration  each actuator exerts unit force alone  and the surface variation is tested and taken as the response function of the actuator. The response functions of all actuators compose the stiffness matrix. Then the stiffness matrix is used by damped least square method to determine the correction force of each active support. In order to analyze the correction capability of the active supports  14 Zernike modes of the mirror surface are generated and tested respectively  and 7 modes are selected for correction. Initially  the RMS error of mirror surface is 1.16 I( =0.6328nm)when all actuators exert the same force. After 5 iterations  the RMS error of mirror surface is reduced to 0.13  close to the original surface quality. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Model identification and closed-loop confirmation for opto-electronic platform of seeker (EI CONFERENCE) 会议论文  OAI收割
2010 2nd International Conference on Industrial Mechatronics and Automation, ICIMA 2010, May 30, 2010 - May 31, 2010, Wuhan, China
作者:  
Liu H.;  Zhang J.;  Zhang J.;  Zhang J.;  Chen J.
收藏  |  浏览/下载:40/0  |  提交时间:2013/03/25