中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共10条,第1-10条 帮助

条数/页: 排序方式:
Study on infrared transparent radar double band-pass filter (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Mechatronics and Materials Processing, ICMMP 2011, November 18, 2011 - November 20, 2011, Guangzhou, China
Jia H. Y.; Feng X. G.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
To realize the functions of infrared transparent as well as radar double- pass Band  A Y loop and Y slot compound element Frequency Selective Surface (FSS) structure is proposed  which takes an infrared transparent inductive mesh as a substrate. The proposed structure is analyzed based on Galerkin spectral method. The transitivity of infrared (3um-5um) as well as the radar double passed band with two resonance frequencies (31GHz and 54GHz) is discussed. The result reveals that this structure has function of infrared transparent as well as stable radar double-band filter with effective shielding effect on S-band and C-band radar electromagnetic waves. The design with multiple passband is suitable for radar/IR composite guidance and it also offers a kind of new thinking way of design for multi-mode compound guidance systems. 2011 Trans Tech Publications.  
Energy transfer in Y3Al5O12:Ce 3, Pr3+ and CaMoO4:Sm3, Eu 3 phosphors (EI CONFERENCE) 会议论文  OAI收割
作者:  
Wang L.;  Wang X.-J.;  Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
Non-radiative energy transfers (ET) from Ce3 to Pr3+ in Y3Al5O12:Ce3  Pr3+ and from Sm3 to Eu3 in CaMoO4:Sm3  Eu3 are studied based on photoluminescence spectroscopy and fluorescence decay patterns. The result indicates an electric dipoledipole interaction that governs ET in the LED phosphors. For Ce3 concentration of 0.01 in YAG:Ce3  Pr3+  the rate constant and critical distance are evaluated to be 4.510-36 cm 6 s-1 and 0.81 nm  respectively. An increase in the red emission line of Pr3+ relative to the yellow emission band of Ce 3  on increasing Ce3 concentration is observed. This behavior is attributed to the increase of spectral overlap integrals between Ce3 emission and Pr3+ excitation due to the fact that the yellow band shifts to the red spectral side with increasing Ce3 concentration. In CaMoO4:Sm3  Eu3  Sm 3Eu3 transfer occurs from 4G5/2 of Sm3 to 5D0 of Eu3. The rate constant of 8.510-40 cm6 s-1 and the critical transfer distance of 0.89 nm are evaluated. 2010 Elsevier B.V. All rights reserved.  
Electronic system design of ultraviolet ozone vertical profile probe for aerography satellite (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Song K.; Wang S.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The design of ultraviolet ozone vertical profile probe is illustrated and the electronic system is introduced in detail. The device is a compact  high precision  ultraviolet-vacuum  ultraviolet spectral radiometer  and is used to measure atmospheric solar backscattering spectral radiance and solar spectral irradiance. Noise of the system is analyzed and Numeric accumulation and synchronous demodulation was used to decrease the noise and the zero-drift of the instrument. The solar irradiance at altitude 830 km in 160-400 nm and the backscattering solar spectral radiance in the ultraviolet ozone absorption band at 12 wavelengths from 250 nm to 340 nm are obtained. Test results on orbit show that all the requested function is met successfully and the performance is stable. 2011 IEEE.  
Ground-based measurement of the space object temperature (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wu Y.-H.;  Wang J.-L.;  Wang J.-L.
收藏  |  浏览/下载:72/0  |  提交时间:2013/03/25
Multi-band IR data of the space object can be used in the fields of object identification and space surveillance. The radiation characteristics of the object can be obtained by analyzing these data. These characteristics include temperature  area  emissivity  absorptivity  reflectivity  and temporal trends. The infrared radiation temperature of the space object is an important characteristic from which the object's working state in orbit can be judged. We apply the method of measuring the spectral distribution of the object and fit the data to the Planck formula to determine the temperature. In order to improve the precision of measuring temperature on the space object  we optimize the centric wavelength and the bandwidth effectively. Also  we use a simple program to implement temperature measurement. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Static micro-michelson interferometer based on electro-optical effect (EI CONFERENCE) 会议论文  OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Design, Manufacturing, and Testing of Micro- and Nano-Optical Devices and Systems, November 19, 2008 - November 21, 2008, Chengdu, China
作者:  
He X.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
UV-VUV spectral irradiance responsivity calibration for space remote sensing spectroradiometer (EI CONFERENCE) 会议论文  OAI收割
Advanced Materials and Devices for Sensing and Imaging III, November 12, 2007 - November 14, 2007, Beijing, China
作者:  
Yu H.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
In order to overcome the irradiance responsivity calibration troubles caused by the weak response of most spectral radiometers in ultraviolet band and poor ratio of signal to noise  and to meet special calibration condition for some remote sensing spectroradiometers in space  a spectral irradiance responsivity calibration unit based on parallel light illumination mode is established  it is composed of a 150W deuterium lamp and a spherical mirror. The calibration unit gets the output standard value of spectral irradiance by irradiance transfer  this way avoids the spectral reflectance measurement difficulty of the spherical mirror. A flight spectral radiometer model used for space remote sense was calibrated in range from 160nm to 300nm  the calibration error of spectral irradiance responsivity is 4.7%. Some factors which contribute to calibration uncertainties are discussed.  
Improved best tradeoff for high-resolution image fusion based on spectral reflection function 会议论文  OAI收割
International Conference on Earth Observation Data Processing and Analysis, ICEODPA,, Wuhan, China, December 28, 2008 - December 30,2008
Wang, Zhongwu; Zhao, Zhongming
收藏  |  浏览/下载:26/0  |  提交时间:2014/12/07
This paper extended the best tradeoff fast intensity-hue-saturation (BTFIHS) fusion to a more general model. Firstly  based-on the methods proposed by previous researches  we integrated injecting strategy of spatial detail information into the fusion model and also adopted the idea of BTFIHS to keep the intensity unchanged with the corresponding pixel in panchromatic (PAN) image  while the hue and saturation of every pixel using BTFIHS were equal to them using tradeoff fast intensity-hue-saturation (TFIHS). Then we got a general formula of the improved best tradeoff for high-resolution image fusion based-on getting injecting parameter by spectral reflection function (SRF). At last  several experiments were carried on to analysis and discuss the quality of the new methods compared with their originals. Results show that the new method could yield a "true" high-resolution multispectral (MS) image  with vast improvement in blue band and nearly 3.3% improvement in Q4 for all bands. 2008 SPIE.  
The study of optical property for CdS nanocrystalline prepared by precipitation method (EI CONFERENCE) 会议论文  OAI收割
ICO20: Materials and Nanostructures, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Zhang S.;  Li W.;  Li W.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
Er3+-Doped lutetium borosilicate glass for optical signal amplification at 1.5 m (EI CONFERENCE) 会议论文  OAI收割
Infrared Components and their Applications, November 8, 2004 - November 11, 2004, Beijing, China
作者:  
Wang X.;  Wang X.;  Wang X.;  Zhang J.;  Zhang J.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
The role of radiometric calibration for the vegetation indices of CBERS-02 WFI 会议论文  OAI收割
IGARSS 2005: IEEE International Geoscience and Remote Sensing Symposium, Vols 1-8, Proceedings, New York
Li, XY; Gu, XF; Yu, T; Fu, QY; Zhang, Y; Li, XW
收藏  |  浏览/下载:18/0  |  提交时间:2014/12/07