Real-time temperature estimation method for electromagnetic performance improvement of a large axisymmetric radio telescope under solar radiation
期刊论文
OAI收割
Iet Microwaves Antennas & Propagation, 2020, 卷号: 14, 期号: 13, 页码: 1635-1642
作者:
Lian, Peiyuan
;
Wang, Congsi
;
Xu, Qian
;
Xiang, Binbin
;
Shi, Yu
  |  
收藏
  |  
浏览/下载:44/0
  |  
提交时间:2021/06/25
radiotelescopes
temperature sensors
reflector antennas
solar
radiation
temperature database
table look-up method
temperature field
estimation speed
real-time estimated temperature field
temperature
sensors
real-time compensation
axisymmetric telescopes
time
temperature estimation method
electromagnetic performance improvement
axisymmetric radio telescope
solar radiation
electromagnetic
performances
EM performance improvements
temperature simulation
fast
estimation method
transient temperature field simulation
high-frequency radio telescopes
large-aperture radio telescopes
reflector antenna
reflector antennas
surface error
adjustment
pattern
field
Engineering
Telecommunications
Performance test of steel tube enclosed thermistors in air temperature measurements (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:
Yang H.
;
Yan F.
;
Yan F.
;
Peng J.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
The performances of two steel tube enclosed precision thermistors are tested in a well controlled air environment to determine if the thermistors have enough accuracy for 0.01C levels of air temperature gradient measurement. Three Fluke's 5641 and three 5610 thermistors were tested for 24 hours in Fluke's 7008 calibration bath in the first step. In the second step
the performances of these two thermistors in steady state and transient state air temperature environments were tested for 8 hours separately. The results illustrate that
two of the 5641s were airproofed in a temperature well controlled tube
when steel tube enclosed precision thermistors are used in air temperature measurement
there are unstable departures from each other with a maximum 8.8 mC in constant air medium and 27 mC in temperature changing air medium. The transient-time errors are too large to show the true amounts of temperature changes for air temperature measurement. 2011 IEEE.
Transient Performances of a Two-Pass Gas-to-Gas Crossflow Heat Exchanger
期刊论文
OAI收割
JOURNAL OF THERMAL SCIENCE, 1998, 卷号: 7, 期号: 1, 页码: 67,70
Song-Junxiao
;
Lin-Guiping
;
Yuan-Xiugan
收藏
  |  
浏览/下载:12/0
  |  
提交时间:2013/03/12
lumped parameter
transient performances
heat exchanger.