Concentrations, Compound Profiles, and Possible Sources of Organic UV Filters in Human Milk in China 期刊论文  OAI收割
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 页码: 1-11
作者:  
Liu, Yang;  Gao, Lirong;  Qiao, Lin;  Huang, Di;  Lyu, Bing
  |  收藏  |  浏览/下载:18/0  |  提交时间:2023/02/06
Linearity measurement for image-intensified CCD (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang L.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Yan F.
收藏  |  浏览/下载:30/0  |  提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)  technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed  and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system  and calibration of the filters' transmittance in different working positions has been done. Meanwhile  to assure the uniform of the received radiation on the target of the detector at any test points  an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization  the attenuation film with transmission  integrating sphere  optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument  the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Development and radiance calibration of three-waveband camera (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Sun Q.;  Liu Y.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path  the required waveband was selected. The optical system which can image in ultraviolet  visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost  small size and light in weight. To obtain a high imaging quality  the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments  the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet  0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.