中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
生态环境研究中心 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2022 [1]
2010 [2]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Concentrations, Compound Profiles, and Possible Sources of Organic UV Filters in Human Milk in China
期刊论文
OAI收割
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 页码: 1-11
作者:
Liu, Yang
;
Gao, Lirong
;
Qiao, Lin
;
Huang, Di
;
Lyu, Bing
  |  
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2023/02/06
ultraviolet filters
human milk
profiles
possible sources
risk assessment
Linearity measurement for image-intensified CCD (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang L.
;
Zhao Y.
;
Zhao Y.
;
Zhao Y.
;
Yan F.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)
technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed
and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system
and calibration of the filters' transmittance in different working positions has been done. Meanwhile
to assure the uniform of the received radiation on the target of the detector at any test points
an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization
the attenuation film with transmission
integrating sphere
optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument
the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.
Development and radiance calibration of three-waveband camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
作者:
Wang J.
;
Liu Y.
;
Liu Y.
;
Sun Q.
;
Liu Y.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path
the required waveband was selected. The optical system which can image in ultraviolet
visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost
small size and light in weight. To obtain a high imaging quality
the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments
the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet
0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.