中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共13条,第1-10条 帮助

条数/页: 排序方式:
Optimization of the gravity support in CFETR vacuum vessel 期刊论文  OAI收割
FUSION ENGINEERING AND DESIGN, 2021, 卷号: 172
作者:  
Ni, Xiaojun;  Han, Songbo;  Ge, Jian;  Sun, Jinxin
  |  收藏  |  浏览/下载:30/0  |  提交时间:2022/01/10
Particle flux characteristics of a compact high-field cascaded arc plasma device 期刊论文  OAI收割
Plasma Science and Technology, 2021, 卷号: 23
作者:  
YUAN,Xiaogang;  ZHOU,Haishan;  LIU,Haodong;  LI,Bo;  WANG,Yong
  |  收藏  |  浏览/下载:40/0  |  提交时间:2021/11/01
Design of Electron Beam Welding Vacuum Chamber for Collar Rings in CFETR Windows 期刊论文  OAI收割
JOURNAL OF FUSION ENERGY, 2017, 卷号: 36, 期号: 4-5, 页码: 127-133
作者:  
Zhu, Lin;  Wu, Jiefeng;  Liu, Zhihong;  Ma, Jianguo
  |  收藏  |  浏览/下载:20/0  |  提交时间:2018/08/16
Large photocathode 20-inch PMT testing methods for the JUNO experiment 期刊论文  OAI收割
JOURNAL OF INSTRUMENTATION, 2017, 卷号: 12
作者:  
Anfimov, N
  |  收藏  |  浏览/下载:18/0  |  提交时间:2023/03/27
ITER vacuum vessel structural analysis completion during manufacturing phase 期刊论文  OAI收割
FUSION ENGINEERING AND DESIGN, 2016, 卷号: 109, 期号: 无, 页码: 688-692
作者:  
Martinez, J. -M.;  Alekseev, A.;  Sborchia, C.;  Choi, C. H.;  Utin, Y.
收藏  |  浏览/下载:35/0  |  提交时间:2017/12/18
多尺度结构超润滑碳基薄膜的设计、真空延寿及机理 学位论文  OAI收割
理学博士, 北京: 中国科学院大学, 2016
作者:  
宋惠
收藏  |  浏览/下载:24/0  |  提交时间:2016/11/25
A new manufacturing technology of radio telescope panel 会议论文  OAI收割
SPIE vol.9673, 北京, 2015-5-5
作者:  
Pengzhi LI;  Yi CHEN
收藏  |  浏览/下载:38/0  |  提交时间:2016/01/21
Design and experimental research of a new type focus mechanism used in space-based telescope (EI CONFERENCE) 会议论文  OAI收割
2012 9th IEEE International Conference on Mechatronics and Automation, ICMA 2012, August 5, 2012 - August 8, 2012, Chengdu, China
作者:  
Wang D.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
The position of focal plane will be changed because of temperature fluctuation and vacuum environment. In order to make the telescope work well  positioning accuracy of the mechanism is 0.008mm. The performance satisfies the need of precision  a focusing mechanism is needed. To majority of large space-based telescopes  and the scheme design is reasonable and practicable. 2012 IEEE.  the general way to do this would be to use a reflector  which was located in the backfocal distance. One of typical schemes of this mechanism was introduced  however  because of the big axial size  the mechanism can't be used when the size of the enclosure was limited. A new type of focusing mechanism was introduced  which has such advantages of small size  high accuracy and low mass. The design and test methods had been discussed. According to the results  the repeatability positioning accuracy is 0.0025mm  
The investigation of point defect modes of phononic crystal for high Q resonance (EI CONFERENCE) 会议论文  OAI收割
2011 16th International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS'11, June 5, 2011 - June 9, 2011, Beijing, China
作者:  
Liu J.;  Liu J.;  Liu J.;  Li F.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
Electronic system design of ultraviolet ozone vertical profile probe for aerography satellite (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Song K.; Wang S.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The design of ultraviolet ozone vertical profile probe is illustrated and the electronic system is introduced in detail. The device is a compact  high precision  ultraviolet-vacuum  ultraviolet spectral radiometer  and is used to measure atmospheric solar backscattering spectral radiance and solar spectral irradiance. Noise of the system is analyzed and Numeric accumulation and synchronous demodulation was used to decrease the noise and the zero-drift of the instrument. The solar irradiance at altitude 830 km in 160-400 nm and the backscattering solar spectral radiance in the ultraviolet ozone absorption band at 12 wavelengths from 250 nm to 340 nm are obtained. Test results on orbit show that all the requested function is met successfully and the performance is stable. 2011 IEEE.