中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共7条,第1-7条 帮助

条数/页: 排序方式:
STABLE STANDING WAVES OF NONLINEAR FRACTIONAL SCHRODINGER EQUATIONS 期刊论文  OAI收割
COMMUNICATIONS ON PURE AND APPLIED ANALYSIS, 2022, 页码: 33
作者:  
Li, Zaizheng;  Zhang, Qidi;  Zhang, Zhitao
  |  收藏  |  浏览/下载:28/0  |  提交时间:2023/02/07
Combined Effects of Hillslope-Concentrated Flows and Riverine Stream Waves on Soil Erosion in the Reservoir Riparian Zone 期刊论文  OAI收割
WATER, 2021, 卷号: 13, 期号: 23, 页码: 11
作者:  
Bao, Yuhai;  Yu, Yantong;  Tang, Qiang;  He, Xiubin;  Wei, Jie
  |  收藏  |  浏览/下载:55/0  |  提交时间:2022/03/10
Combined Effects of Hillslope-Concentrated Flows and Riverine Stream Waves on Soil Erosion in the Reservoir Riparian Zone 期刊论文  OAI收割
WATER, 2021, 卷号: 13, 期号: 23, 页码: 11
作者:  
Bao, Yuhai;  Yu, Yantong;  Tang, Qiang;  He, Xiubin;  Wei, Jie
  |  收藏  |  浏览/下载:38/0  |  提交时间:2022/08/22
Biomechanical response of a submerged, rosette-forming macrophyte to wave action in a eutrophic lake on the Yungui Plateau, China 期刊论文  OAI收割
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 卷号: 25, 期号: 34, 页码: 34027-34045
作者:  
Zhu, Guorong;  Di, Guilan;  Zhang, Meng;  Cao, Te;  Ni, Leyi
  |  收藏  |  浏览/下载:98/0  |  提交时间:2019/07/01
Electrically pumped organic laser device with a coupled microcavity structure (EI CONFERENCE) 会议论文  OAI收割
Organic Light Emitting Materials and Devices XVI, August 12, 2012 - August 15, 2012, San Diego, CA, United states
作者:  
Li Y.;  Li Y.;  Li Y.;  Li Y.;  Lin J.
收藏  |  浏览/下载:21/0  |  提交时间:2013/03/25
1D-KBA microscope using double-periodic multilayer (EI CONFERENCE) 会议论文  OAI收割
Advances in X-Ray/EUV Optics and Components IV, August 3, 2009 - August 5, 2009, San Diego, CA, United states
作者:  
Wang Z.;  Wang X.;  Wang X.;  Wang X.;  Wang Z.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
To study the action of shock wave in CH target  one-dimensional grazing incidence KBA microscope for 4.75keV energy was set up. Because of strong absorption in air  4.75keV energy microscope can just work in vacuum. Accordingly  the alignment and assemblage will be very complicated and difficult. A special multilayer method  using double periodic multilayer  was proposed to solve this problem. This multilayer has high reflectivity not only for 4.75keV X-rays but also for 8keV X-rays at the same grazing incidence angle. It means 1D-KBA microscope has the same light trace for different working energies. Therefore  we can implement the alignment and assembly of 4.75keV system by the help of 8keV X-rays. Because 8keV X-rays is very easy produced by X-ray tube and has strong transmittability in air  the alignment and assemblage process became relatively easy. By now  we have finished the alignment experiment at 8keV and obtained imaging results. The performance is about 2-3m resolution in 250m field of view. It is coincide with the calculation. 2009 SPIE.  
Athermal design of hybrid refractive/harmonic diffractive optical system for far-infrared multi-band (EI CONFERENCE) 会议论文  OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Advanced Optical Manufacturing Technologies, November 19, 2008 - November 21, 2008, Chengdu, China
作者:  
Liu Y.;  Liu Y.;  Zhang H.;  Zhang H.;  Sun Q.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
In order to get enough information about the target  avoid big chromatic aberration as a result of wide spectrum and the complexity of optical system and adapt different special environment temperature  a hybrid refractive/harmonic diffractive optical system in far-infrared multi-band is described in the paper. This diffractive optical system has been designed an athermalized multi-band imaging system with harmonic diffractive element in 15-50m spectrum  based on larger 1dispersion capability and particular thermal dispersive power of harmonic diffractive element. Then  at the temperature range from 0C to 40C  this design can simultaneously meet with all requirements of the imaging system in five harmonic wave bands  including15.8-16.2m  18.5-20m  23-25m  30.5-33.5m and 46-50m. In each harmonic wave band  the magnification changes as a function of wavelength  which creates image registration error. To compensate this shortcoming  a zoom optical system is designed with three lenses by means of optical two- component method. The design results show that the hybrid refractive/harmonic diffractive optical system can realize athermalized and achromatic design  and the zoom optical system makes half image height at 3.53mm in every harmonic wave band and still realizes aberration compensation action. In the five harmonic wave bands  each optical transfer function approaches the diffraction limit at ambient temperature range of 0C to 40C. Finally  the system realizes the requirements of portability  mini-type and ease for fabrication. 2009 SPIE.