中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
X-ray communication experiment using photocathode X-ray tube 会议论文  OAI收割
Kunming, China, 2020-11-05
作者:  
Liu, Yong-An;  Xuan, Hao;  Sheng, Li-Zhi;  Qiang, Peng-Fei;  Su, Tong
  |  收藏  |  浏览/下载:37/0  |  提交时间:2021/04/12
Formability improvement of austenitic stainless steel by pulsating hydroforming 期刊论文  OAI收割
Proceedings of the Institution of Mechanical Engineers Part B-Journal of Engineering Manufacture, 2015, 卷号: 229, 期号: 4, 页码: 609-615
Y.; Zhang Xu, S. H.; Cheng, M.; Song, H. W.
收藏  |  浏览/下载:32/0  |  提交时间:2015/05/08
Experimental research on the feature of an x-ray Talbot-Lau interferometer versus tube accelerating voltage 期刊论文  OAI收割
CHINESE PHYSICS B, 2015, 卷号: 24, 期号: 6, 页码: 68703
作者:  
Wang, SH;  Olbinado, MP;  Momose, A;  Han, HJ;  Hu, RF
收藏  |  浏览/下载:21/0  |  提交时间:2016/04/18
Research of X-ray pulsar navigation simulation source 期刊论文  OAI收割
acta physica sinica, 2013, 卷号: 62, 期号: 12
作者:  
Sheng Li-Zhi;  Zhao Bao-Sheng;  Wu Jian-Jun;  Zhou Feng;  Song Juan
收藏  |  浏览/下载:18/0  |  提交时间:2015/06/03
An analog modulated simulation source for X-ray pulsar-based navigation 期刊论文  OAI收割
acta physica sinica, 2013, 卷号: 62, 期号: 11
作者:  
Zhou Feng;  Wu Guang-Min;  Zhao Bao-Sheng;  Sheng Li-Zhi;  Song Juan
收藏  |  浏览/下载:26/0  |  提交时间:2015/06/09
1D-KBA microscope using double-periodic multilayer (EI CONFERENCE) 会议论文  OAI收割
Advances in X-Ray/EUV Optics and Components IV, August 3, 2009 - August 5, 2009, San Diego, CA, United states
作者:  
Wang Z.;  Wang X.;  Wang X.;  Wang X.;  Wang Z.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
To study the action of shock wave in CH target  one-dimensional grazing incidence KBA microscope for 4.75keV energy was set up. Because of strong absorption in air  4.75keV energy microscope can just work in vacuum. Accordingly  the alignment and assemblage will be very complicated and difficult. A special multilayer method  using double periodic multilayer  was proposed to solve this problem. This multilayer has high reflectivity not only for 4.75keV X-rays but also for 8keV X-rays at the same grazing incidence angle. It means 1D-KBA microscope has the same light trace for different working energies. Therefore  we can implement the alignment and assembly of 4.75keV system by the help of 8keV X-rays. Because 8keV X-rays is very easy produced by X-ray tube and has strong transmittability in air  the alignment and assemblage process became relatively easy. By now  we have finished the alignment experiment at 8keV and obtained imaging results. The performance is about 2-3m resolution in 250m field of view. It is coincide with the calculation. 2009 SPIE.